#1 Mine — Accidents
Total: 10 accidents | Fatalities: 0
| Date | Classification | Injury | Days Lost | Narrative |
|---|---|---|---|---|
| 01/16/2007 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | A roof fall was discovered int he No. 6 of the second left pillared panel. The fall measured 80'l x 20'w x 7'h. The fall was located 30' inby station #1204. |
| 12/27/2006 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | A roof fall was discovered in No. 2 return entry 300' outby the face area of the No. 1 South. The fall measured 8' H x 20' W x 85' L. Ventilation and travel was not affected. |
| 09/05/2006 | MACHINERY | DAYS AWAY FROM WORK ONLY | None | The operator of the fletcher roof bolter dropped the head of the machine on his knee. |
| 06/19/2006 | HANDLING OF MATERIALS | DAYS AWAY FROM WORK ONLY | 55d lost | The injured man stated that while unloading timbers from a scoop, he felt a sharp pain in his abdomen. |
| 08/23/2005 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | A roof fall occured approx. 1600' outby the 001 section fall measured 65Lx7'Hx20'W. The fall was located 60' outby spad 1069 in the No. 3 neutral entry. |
| 06/27/2005 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | A ROOF FALL OCCURRED APPROX. 1200' OUTBY THE 001 SECTION. IT MEASURED 80' LONG X 20' WIDE X 8' HIGH. THE LOCATION WAS IN THE INTAKE JUST OUTBY SURVEY STATION #1056 IN THE #6 ENTRY. |
| 02/16/2005 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | A roof fall was discovered in the return (no. 1 entry). The fall 18' in width, 40' in length and 7' in height. It was located 400' outby face area at spad 1082. |
| 08/12/2004 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | A ROOF FALL WAS DISCOVERED IN THE RETURN (NO. 1 ENTRY) OF THE 001 SECTION. IT BEGAN 80' INBY SPAD NO. 1024 AND EXTENDED 70' UP TO THE NO. 1 ENTRY. THE FALL WAS 20' WIDE AND APPROXIMATELY 7' HIGH. |
| 07/18/2003 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | A ROOF FALL WAS DISCOVERED IN THE INTERSECTION OF NO.3 HEADING ON THE 001 SECTION ONE CROSSCUT OUTBY FACE. SPAD NO. 916. |
| 06/14/2003 | POWERED HAULAGE | NO DYS AWY FRM WRK,NO RSTR ACT | None | THE VICTIM WAS TRAVELING UNDER THE HUNG MINER CABLE WHEN HIS SHUTTLE CAR CAME INTO CONTACT WITH CABLE TEARING IT DOWN AND CUTTING HIM BEHIND THE LEFT EAR. |