Buchanan Mine #1 — Accidents
Total: 688 accidents | Fatalities: 8
| Date | Classification | Injury | Days Lost | Narrative |
|---|---|---|---|---|
| 08/17/2005 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | An unintentional roof fall was discovered in the #4 entry of grassy creek mains at survey station # 22023 approx 4,500 ft from the nearest working face. Ventilation was not disrupted, no machinery was... |
| 08/17/2005 | FALL OF ROOF OR BACK | NO DYS AWY FRM WRK,NO RSTR ACT | None | Employee was standing at the headgate control box on 7 right longwall. a rock 18"" wide by 19"" long and 0 to 8"" thick fell from between the bolts and struck him on his right wrist just above the glo... |
| 08/06/2005 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | THE TAILGATE OF THE 7 RIGHT LONGWALL SECTION BECAME BLOCKED DUE TO ROCK FALLING OUT BETWEEN THE CRIB LINE AND THE SOLID COAL BLOCK. THE LOCATION OF THE LONGWALL FACE WAS APPROX 10,700'. VENTILATION WA... |
| 07/21/2005 | HOISTING | ACCIDENT ONLY | None | The page portal service elevator overtraveled due to a bad electrical relay. The elevator was down for 20 hours, from 8:00 PM on 7/21 until 4:00 PM on 7/22/05. The relay was replaced, the elevator was... |
| 07/14/2005 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | AN UNINTENTIONAL ROOF FALL OCCURRED ON 3 EAST MAINS, BREAK 55, BETWEEN THE 7TH AND 8TH ENTRY. THIS FALL MEASURED 20' WIDE, 25' LONG AND 6+' THICK. THERE WERE NO INJURIES AND NO EQUIPMENT WAS DAMAGED O... |
| 07/03/2005 | HANDLING OF MATERIALS | NO DYS AWY FRM WRK,NO RSTR ACT | None | THE INJURED WAS HELPING CHANGE OUT A 2"" WATER LINE ON 1 EAST MAINS BELT AT BREAK #32, WHEN HE SQUATTED DOWN TO TAKE THE BOLTS OUT OF THE VICTOLIC COUPLING HE STRUCK HIS LEFT KNEE AGAINST A BOTTOM BEL... |
| 06/29/2005 | HANDLING OF MATERIALS | NO DYS AWY FRM WRK,NO RSTR ACT | None | Employee was helping load 6"" steel water line. While one employee was trying to dislodge a piece of water line off the stack, the injured employee reached in to help free it just as the other one mov... |
| 06/17/2005 | HOISTING | ACCIDENT ONLY | None | The contrary service cage was down from 11:20 pm until 1:00 am to repair the grating that was damaged due to a chain that was being used as a supply car safety chain getting fouled at the surface land... |
| 06/17/2005 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | AN UNINTENTIONAL ROOF FALL WAS DISCOVERED IN THE #1 ENTRY OF 4 NORTH MAINS AT BREAK #95 SURVEY STATION #18507. THE SIZE OF THE FALL IS APPROX 20' WIDE X 40' LONG X HEIGHT UNKNOWN. NO INJURIES OR EQUIP... |
| 06/04/2005 | HANDLING OF MATERIALS | PERM TOT OR PERM PRTL DISABLTY | 28d lost | Injured was using a 4 ft bar to steady an H-beam that was being jacked back into place on an overcast, as pressure was being applied to the track jack that sitting on top of a 4 ft crib (top layer sol... |
| 05/29/2005 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | An unintentional roof fall was discovered by mine rescue teams. On 4 North Mains at survey station # 18127, size of fall is approximately 20ft. wide x 40ft. long x height unknown. No injuries or equip... |
| 05/26/2005 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | An unintentional roof fall was discovered by mine rescue teams, on Grassy Creek Mains at survey station # 19835 and extending inby to survey station # 15773 size of fall approximately 20ft. wide x 170... |
| 05/26/2005 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | An unintentional roof fall was discovered by mine rescue teams at approximately 12:46am on Grassy Creek Mains at survey station # 15795, size of fall is approximately 20ft. wide x 40ft. long x height... |
| 05/26/2005 | HOISTING | ACCIDENT ONLY | None | THE CONTRARY SERVICE CAGE WAS DOWN FOR APPROX. 10 HOURS DUE TO ROPE DAMAGE. THERE WERE NO PERSONS ON THE CAGE. THERE WERE NO INJURIES DUE TO THIS INCIDENT. |
| 05/25/2005 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | An unintentional roof fall was discovered by mine rescue teams at approximately 11:28am in the #1 entry on Grassy Creek Mains starting approx 120ft inby survey station # 15977 and extending inby to su... |
| 05/23/2005 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | An unintentional roof fall was discovered by mine rescue teams at approximately 9:30am at break # 37 on 3 East Mains approximately 120ft. inby survey station # 20175, size of fall is approximately 20f... |
| 05/23/2005 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | An unintentional roof fall was discovered on 4 North Mains at survey station # 18428 and extending right handed to survey station # 18437, size of fall is approximately 20ft. wide x 130ft. long x heig... |
| 05/16/2005 | HANDLING OF MATERIALS | PERM TOT OR PERM PRTL DISABLTY | None | On the surface at Vent Shaft #8, The injured ee and one other ee was attempting to lift one end of metal grating (36 in. x 20 ft). It slipped catching the injured ee right middle finger tip between th... |
| 04/17/2005 | SLIP OR FALL OF PERSON | NO DYS AWY FRM WRK,NO RSTR ACT | None | ON THE 3RD FLOOR OF THE PREP PLANT ATTEMPTING TO PULL A CYCLONE INTO PLACE. AS EE REACHED TO GRAB THE CHAIN, EE USED OTHER HAND TO GRAB A HANDRAIL, WHICH HAD BEEN REMOVED TO FACILITATE THE JOB, INSTEA... |
| 02/14/2005 | FIRE | ACCIDENT ONLY | None | The 001 longwall shearer was preparing to ""cut out"" on the tailside of the face when a bump occured that apparently forced a pocket of methane from the gob onto the face at the shearer resulting in... |
| 01/30/2005 | IGNITION OR EXPLOSION OF GAS OR DUST | ACCIDENT ONLY | None | Methane ignition occurred in face of #2 left crosscut on Grassy Creek Mains section, 78' left handed of survey station #23273. Ignition occurred as miner was loading the std. shuttle car ont he left s... |
| 01/23/2005 | HANDLING OF MATERIALS | NO DYS AWY FRM WRK,NO RSTR ACT | None | EE WAS HELPING REMOVE A GUARD ON THE CLARIFIED PUMP, LOCATED ON THE BOTTOM FLOOR OF THE PREP PLANT. AS ANOTHER EE SPRAYED PENITRATING OIL ON THE BOLTS, SOME OF THE OIL ENTERED INTO THE INJURED EE LEFT... |
| 01/13/2005 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | An unintentional roof fall was discovered on 4 North Mains in the #2 entry at survey station #17941 at approx. 10am. The size of the fall was approx. 20'W x 20'L, height is unknown. No equipment was c... |
| 11/30/2004 | HOISTING | ACCIDENT ONLY | None | PAGE PORTAL SERVICE CAGE WAS SHUT DOWN FOR 4 HOURS TO DO REPAIR TO THE LOWER BULL WHEEL. |
| 11/10/2004 | HOISTING | ACCIDENT ONLY | None | THE CONTRARY PORTAL SERVICE CAGE WAS DOWN FOR APPROXIMATELY TWO HOURS AND 45 MINUTES DUE TO A ROPE COMING OFF OF A COUNTERWEIGHT SHEEVE WHEEL. THIS OCCURRED DURING TESTING OF THE EMERGENCY STOP SYSTEM... |
| 10/05/2004 | HOISTING | ACCIDENT ONLY | None | The Page Portal Service Cage was down for 1 hr and 15 min due to high voltage fuse blowing, the fuse was replaced and the Page Portal Service Cage was back into service. There were no people on the se... |
| 09/26/2004 | POWERED HAULAGE | FATALITY | Fatal | EMPLOYEE WAS HELPING CHANGE OUT A BOTTOM BELT SCRAPER AT 3 EAST MAINS #1 TAILPIECE. EMPLOYEE WAS PULLED INTO THE TAILPIECE RESULTING IN FATAL INJURIES. |
| 09/07/2004 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | AN UNINTENTIONAL ROOF FALL WAS DISCOVERED ON 3 EAST MAINS IN THE #6 ENTRY OF SURVEY STATION #20744. THE SIZE OF THE FALL IS 20'WIDE X 30'LONG X 10'HIGH, WHICH INVOLVED AN INTERSECTION. THERE WERE NO I... |
| 08/29/2004 | HANDLING OF MATERIALS | DAYS AWAY FROM WORK ONLY | 19d lost | Ee was putting cat head back in on 7 right #3 belt drive. As he was twisting the cat head to line it up he felt a pain in his left ring finger, which resulted in torn ligaments & tendons to his left r... |
| 08/07/2004 | HANDLING OF MATERIALS | DAYS AWAY FROM WORK ONLY | 85d lost | Employee was helping load belt onto a flat car using a single tree at 3 east #2 belt. one side of the single tree came loose and struck the ee on his right forearm, resulting in a fracture to his righ... |
| 07/24/2004 | HANDLING OF MATERIALS | DAYS AWAY FROM WORK ONLY | 27d lost | Employee was shoveling mud at 4 North #1 Discharge, and felt pain in lower abdomen. EE started missing work on 8-4-04. |
| 07/20/2004 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | An unintentional roof fall occurred at survey station 20818 and extending into the 5 rt l.w. face cut out entry. Fall is 20 ft wide, 60 ft long and approx. 20 ft high. This fall will be cleaned up, us... |
| 07/19/2004 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | An unintentional roof fall was discovered on grassy creek mains #1 entry, between survey station 18751 and survey station 18801. fall size is approx. 20 ft wide x 40 ft long x 7 ft thick. there were n... |
| 07/12/2004 | SLIP OR FALL OF PERSON | DAYS AWAY FROM WORK ONLY | 141d lost | EMPLOYEE WAS REPLACING #2 JUMP PUMP IN THE STACKER TUNNEL AT THE TAIL PIECE & SAID HE FELL IN THE SUMP WHICH IS 3'DEEP, TWISTING HIS LEFT KNEE. THIS EE BEGAN TO MISS WORK ON 8/19/04. |
| 07/11/2004 | ENTRAPMENT | ACCIDENT ONLY | None | A power outage occurred at approx 8:50 pm. which resulted in a single phase condition. this condition caused failure of the breake pump motor for the mini cage at the production shift. 3 men were on t... |
| 06/22/2004 | HANDTOOLS (NONPOWERED) | DAYS AWAY FROM WORK ONLY | 10d lost | When coupling 4 inch pvc pipe together, by stricking one end of the pipe with 2 foot 2x4. when swing 2x4 he felt a pain in his right elbow. |
| 06/20/2004 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | AN UNINTENTIONAL ROOF FALL WAS DISCOVERED ON 6 RIGHT SECTION, ONE BREAK INBY SPAD #22344 IN THE #2 ENTRY. THE APPROXIMATE DIMENSIONS OF THE ROCK FALL AREA ARE 10+ FT X 30FT X 50FT. |
| 06/13/2004 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | AN UNINTENTIONAL ROOF FALL WAS DISCOVERED ON GRASSY CREEK MAINS, ONE BREAK OUTBY SPAD #21580 IN THE NUMBER 3 ENTRY. THE APPROX DIMENSIONS OF THE ROCK FALL AREA IS 10""H, 25' L X 40'WIDE. |
| 05/17/2004 | HANDTOOLS (NONPOWERED) | DAYS AWAY FROM WORK ONLY | 35d lost | ON THE FIRST FLOOR OF THE PREP PLANT, EMPLOYEE WAS PULLING THE VC48 FEED CHUTE TOWARD THE BYPASS CHUTE USING THE RATCHET CABLE HOIST, AND FELT PAIN IN HIS LOWER RIGHT SIDE. THIS EMPLOYEE STARTED MISSI... |
| 05/05/2004 | MACHINERY | DAYS AWAY FROM WORK ONLY | 62d lost | Employee was bolting top in the #2 heading on grassy creek mains section. As the operator started to raise the ATRS for the second row of bolts to be installed a rock fell striking the ee on his head,... |
| 05/01/2004 | MACHINERY | NO DYS AWY FRM WRK,NO RSTR ACT | None | THE EE WAS BOLTING ON THE 5TH ROW, PREPARING TO INSTALL HIS SECOND BOLT IN THE 3 LEFT CROSSCUT ON THE GRASSY MAINS SECTION, WHEN A PIECE OF ROCK 18"" X 8"" X 0"" TO 3"" DISLODGED FROM THE ROOF AND STR... |
| 03/31/2004 | HANDLING OF MATERIALS | DAYS AWAY FROM WORK ONLY | 10d lost | REPOSITIONING A PIECE OF CAT WALK APPROX 12' LONG AND CAUGHT HIS RIGHT LITTLE FINGER BETWEEN THE CAT WALK AND CONCRETE TOE BOARD, RESULTING IN AN AVULSION TO THE TIP OF RIGHT LITTLE FINGER. EE STARTED... |
| 03/12/2004 | HANDLING OF MATERIALS | NO DYS AWY FRM WRK,NO RSTR ACT | None | EE WAS HELPING REMOVE THE CANOPY FROM 488 SCOOP ON THE 6 RT DEVELOPMENT SECTION #2 ENTRY BETWEENCROSSCUTS 50 AND 51. AS THE LAST LEG OF THE CANOPY CAME OUT THE CANOPY TILTED CATCHING THE TIP OF HIS LE... |
| 01/30/2004 | IGNITION OR EXPLOSION OF GAS OR DUST | ACCIDENT ONLY | None | A FRICTIONAL METHANE IGNITION OCCURRED IN THE #3 ENTRY ON 6 RIGHT SECTION WHICH RESULTED IN A FIRE WITH A FLAME DURATION OF APPROXIMATELY 40 MINUTES. FIRE WAS EXTINGUISHED WITH A FIRE HOSE. |
| 01/26/2004 | HANDTOOLS (NONPOWERED) | NO DYS AWY FRM WRK,NO RSTR ACT | None | EMPLOYEE WAS WORKING ON THE 5TH FLOOR OF THE PREP PLANT WORKING ON #122 RAW CON/SCREEN. THE SCREEN HAD LOCKED UP AND EMPLOYEE WAS TRYING TO FREE UP SCREEN WITH A PIPE WRENCH ATTACHED TO A COUN TER BAL... |
| 01/23/2004 | IGNITION OR EXPLOSION OF GAS OR DUST | ACCIDENT ONLY | None | A METHANE IGNITION OCCURRED IN THE #2 FACE EAST SECTION. AT APPROX 3:15 PM IN THE #2 FACE OFF THE #8 HEADING. THE FLAME WAS DISCOVERED BY THE MINER OPERATOR. THE FLAME DURATION WAS LESS THAN 2 MINUTES... |
| 01/10/2004 | HANDLING OF MATERIALS | DAYS RESTRICTED ACTIVITY ONLY | 14d restricted | WHILE MUCKING, A PIECE OF FROZEN MUCK FELL FROM THE HINGE OF THE DUMP CHUTE. THE PIECE HIT EE ON HIS RT. SHOULDER. |
| 12/15/2003 | IGNITION OR EXPLOSION OF GAS OR DUST | ACCIDENT ONLY | None | A METHANE IGNITION OCCURRED ON THE (002 MMU) 3 EAST SECTION AT APPROXIMATELY 10:10 PM IN THE #6 HEADING. THE FLAME WAS DISCOVERED BY THE MINER OPERATION. THE FLAME WAS EXTINGUISHED WITH A FIRE EXT. FL... |
| 11/14/2003 | IGNITION OR EXPLOSION OF GAS OR DUST | ACCIDENT ONLY | None | A METHANE IGNITION OCCURRED ON THE 008-MMU 6 RIGHT DEVELOPMENT AT APPROX. 10:10 PM IN THE #4 FACE. THE FLAME WAS DISCOVERED BY THE MINER OPERATOR. THE FLAME WAS EXTINGUISHED BY THE MINER OPERA TOR USI... |
| 11/12/2003 | HOISTING | ACCIDENT ONLY | None | THE PAGE PORTAL SERVICE CAGE WAS DOWN FROM 5:45 AM TO 4:50 PM DUE TO A BAD VOLTAGE REGULATOR AND BAD FIRING CORD. THESE PARTS WERE RELACED AND THE SERVICE CAGE WAS PUT BACK INTO SERVICE. THERE WERE NO... |