Camp Creek Mine — Accidents
Total: 490 accidents | Fatalities: 1
| Date | Classification | Injury | Days Lost | Narrative |
|---|---|---|---|---|
| 10/14/2010 | SLIP OR FALL OF PERSON | NO DYS AWY FRM WRK,NO RSTR ACT | None | While hanging a line curtain, he slipped to fall and cut his thumb on a roof pan. |
| 10/08/2010 | MACHINERY | DAYS AWAY FROM WORK ONLY | 152d lost | As he was tramming the miner, he was standing in the red zone and was struck by the boom. |
| 10/07/2010 | SLIP OR FALL OF PERSON | DAYS AWAY FROM WORK ONLY | 34d lost | EE was unloading 5 gallon oil cans off a flat car. He stumbled and fell to the ground, hurting himself in the groin area. He started to miss work on 10/8/10. |
| 09/11/2010 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | An unplanned roof fall occurred at spad #20079 off the #1 section. The fall was about 80 feet long, 20 feet wide, and 10 feet high. The area was bolted with 5 foot torque tension bolts. The fall will... |
| 09/06/2010 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | An unplanned roof fall occurred on the 011-0 MMU on section #2 in the #2 entry about 480 feet from the face. The fall was about 640 ft long, 18 to 20 ft wide, and 10 to 12 ft high. The area was timber... |
| 08/29/2010 | HOISTING | ACCIDENT ONLY | None | The elevator was down at the Camp Creek Portal for more than 30 minutes due to a bad relay on door. The relay was repaired and the elevator was put back into service. |
| 08/17/2010 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | An unplanned roof fall occured at the 4-way at the bottom of the slope. The fall was about 20' W X 80' L X 8-10' H. the area will be cleaned up and rebolted and additional support where needed. |
| 08/03/2010 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | A roof fall occurred in the belt entry 5 X cut inby #1 north drive. The fall was 20' W X 20' L X 8' H. The area will be cleaned up and rebolted and cribbed on the side. |
| 08/02/2010 | FALL OF ROOF OR BACK | NO DYS AWY FRM WRK,NO RSTR ACT | None | A piece of draw rock fell out between roof bolts, hitting him on the top of the right hand cutting it. EE received 3 stitches. |
| 08/02/2010 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | A roof fall occurred off the #4 section area in the #11 entry at spad #52311. The fall was 20 feet wide, 20 feet long, and about 6 feet high. The area will not be cleaned up. It was cribbed and danger... |
| 07/23/2010 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | a unplan roof fall occured at x-cut #5 on old 7 south track, at spad #15895. The fall was 20 foot wide, 20 foot long and 6 foot high. The area will be cribbed and danger off. |
| 07/19/2010 | HOISTING | ACCIDENT ONLY | None | The elevator at the camp creelportal was down for more than 30 minutes due to a ground in the power leads coming from the substation to the main building. Power was fixed going to the building. Person... |
| 07/19/2010 | FALL OF ROOF OR BACK | NO DYS AWY FRM WRK,NO RSTR ACT | None | Employee was setting a timber and a piece of draw rock fell from the top knocking of his hard hat. A second piece fell hitting him on the head cutting it. The size of the pieces of rock was about 8 in... |
| 06/09/2010 | FALL OF ROOF OR BACK | DAYS AWAY FROM WORK ONLY | 3d lost | While walking up to the power box, a piece of rock fell and hit right shoulder and both hands. |
| 06/03/2010 | FALL OF ROOF OR BACK | DAYS AWAY FROM WORK ONLY | 1d lost | EE was roof bolting in 8 right entry and was putting the last outside bolt in. He just had struck the steel in the pot and a rock fell striking his right hand. |
| 06/02/2010 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | A roof fall occured on the 8 south belt at spad # 43453 between x-cut # 22 & 23. This area was mined around 9/25/2007. The fall was 40 foot long, 19 foot wide and 7 foot high. The are was bolted with... |
| 06/02/2010 | HANDTOOLS (NONPOWERED) | NO DYS AWY FRM WRK,NO RSTR ACT | None | Employee was putting a new knife blade in his knife and it slipped and cut his index finger. He received 4 stitches. |
| 05/18/2010 | FALL OF ROOF OR BACK | NO DYS AWY FRM WRK,NO RSTR ACT | None | While he was walking to hang a piece of curtain a piece draw rock fell out of the top sticking him on the hard hat and right leg. He received 7 sutures. |
| 05/15/2010 | FALL OF ROOF OR BACK | NO DYS AWY FRM WRK,NO RSTR ACT | None | While he was setting timber on the main line a piece of draw rock fell out and hit him in the head and left arm. He received 6 sutures to his head. |
| 05/09/2010 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | A roof fall occurred on the 2 south track one x-cut inby spad #9182. The fall was about 2 to 3 foot high, 10 foot wide and 15 foot long. The area will be cleaned up and rebolted. |
| 04/22/2010 | SLIP OR FALL OF PERSON | DAYS AWAY FROM WORK ONLY | 65d lost | EE was walking around the edge of the feeder and slipped and fall and he went to catch himself with his left hand and arm. He strained his left shoulder. He had surgery on his left shoulder on 7/15/10... |
| 04/19/2010 | HANDTOOLS (NONPOWERED) | NO DYS AWY FRM WRK,NO RSTR ACT | None | EE was cutting a zip tie off the end of a spotter probe. He received 6 sutures. |
| 04/05/2010 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | A small brow fell on the outby end of an overcast, at #4 X-cut on old 9A track. It was about 8' long, 12' wide, and 3-4' high. It was cleaned up and re-bolted. |
| 03/09/2010 | POWERED HAULAGE | DAYS AWAY FROM WORK ONLY | None | EE alleged that he was injured while driving a scoop to the battery station. EE said he hit a hole causing him to bump his head on the canopy of the scoop. EE worked the entire 9 hour shift. |
| 02/02/2010 | HANDLING OF MATERIALS | DAYS AWAY FROM WORK ONLY | 78d lost | Employee was dropping a cross under guard loose from a belt line. The chain that was holding the guard in place was wrapped around a 4 inch water line. He dropped the guard and the chain unrolled very... |
| 01/26/2010 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | A roof fall occurred in the left return behind the surge bin. The fall was about 30' long X 20' wide and 5'-7' high. The fall will not be cleaned up, it was cribbed and dangered off. |
| 01/26/2010 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | A roof fall occurred on the #4 section in the #8 entry 1 x-cut inby spad #50513. The fall was about 35' long X 6'-8' high. The area was bolted with 5' torque tension bolts and 2-12' rope bolts every 3... |
| 01/24/2010 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | A roof fall occurred on the #4 section in the #2 face. The fall was about 40' long X 18' wide X 5'-7' High. The area was bolted with 5' torque tension bolts. The fall will not be cleaned up, it was cr... |
| 01/21/2010 | POWERED HAULAGE | DAYS RESTRICTED ACTIVITY ONLY | 18d restricted | This report is being filed to abate citation #8128500. Employee was in the process of cutting off a piece of metal at 3B tailpiece when a small piece of rock fell from the discharge roller and struck... |
| 01/19/2010 | SLIP OR FALL OF PERSON | DAYS AWAY FROM WORK ONLY | 128d lost | Employee was walking through an open crosscut and stumbled and fell. He tried to catch himself by extending his arm and felt pain in his right arm and shoulder. The employee began missing work on Dece... |
| 01/13/2010 | POWERED HAULAGE | DAYS AWAY FROM WORK ONLY | 367d lost | EE was pulling a big rock off top of a fall with a chain. The chain broke and the scoop went down to the ground bouncing his head and neck into the canopy. |
| 01/11/2010 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | A roof fall occured in the #3 entry, about 1400 ft from the face of the #5 section, at spad #49615. The fall was about 18 ft wide, 25 ft long, and 4 to 7 ft high. The area was bolted with 6 ft torque... |
| 01/03/2010 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | A roof fall occurred on the #3 section about 80' inby spad #50349. The fall was about 12'L, 20'W, and 4 to 7'H. The area was bolted with 5' torque tension bolts. The area was crib and danger off and t... |
| 01/03/2010 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | A roof fall occurred at X-cut #79 an old 6B track. The fall was about 120'L, 20'W, and 4 to 7'H. The area was bolted with 5' torque tension bolts. The area will be cleaned up and rebolted. |
| 12/26/2009 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | A roof fall occurred on the old 5A track across from spad #46684. The fall was 16' long, 20' wide and 6 to 7' high. The fall will be cleaned up and re-bolted. The x-cut was crib off and 2 steel beam s... |
| 12/17/2009 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | A roof fall occurred in the #3 intersection at spad #50251 on the #1 section. The fall was 20' wide, 60' long, and 5 to 6' high. The fall area was bolted with 5 foot torque tension bolts. The fall wil... |
| 11/28/2009 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | A roof fall occurred in the #7 entr7y in the old 9A track area in the intersection at spad #23208. The fall was about 30'long, 20'wide, and 6 to 8' high. The area was bolted with 5' torque tension bol... |
| 11/17/2009 | MACHINERY | NO DYS AWY FRM WRK,NO RSTR ACT | None | EE was cutting a cut of coal in 5' x-cut and a piece of bit broke off and came back hitting him in the left side of the neck that resulted in laceration (4sutures). (The mine was down from 11/19/09 ti... |
| 11/15/2009 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | A roof fall occurred at the #1 section, 1 x-cut outby spad #46221 in the intersection. The fall was about 6'- 8' high, 20' wide, and 30' long. The area was bolted with 5' torque tension bolts. The are... |
| 10/31/2009 | FALL OF ROOF OR BACK | NO DYS AWY FRM WRK,NO RSTR ACT | None | While Injured was spot bolting on new #1 section setup, a piece of rock fell from the top, hitting him on the forehead and nose. He recieved 14 stitches. |
| 10/30/2009 | FALL OF ROOF OR BACK | NO DYS AWY FRM WRK,NO RSTR ACT | None | While Injured was drilling a bolt hole, a piece of draw rock fell from the top, hitting him on the right arm. He received 11 stitches. |
| 10/27/2009 | HANDLING OF MATERIALS | DAYS AWAY FROM WORK ONLY | 4d lost | While loading supply on bolter, Injury turn to pick up a stack of pizza pans and felt pain in his back. |
| 10/27/2009 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | A roof fall occurred on the #5 section outby the feeder in the #4 intersection at spad #49614. The fall was 8-10 feet high, 20' by 20'. The area was bolted with 6' torque tension bolts. and rope bolts... |
| 10/12/2009 | HANDTOOLS (NONPOWERED) | NO DYS AWY FRM WRK,NO RSTR ACT | None | EE was jacking up a take-up at a new belt setup. He was on his knee pushing down on a jack bar and it slipped out, strikin ghim under the left eye and caused a laceration. He received 6 stitches. |
| 10/06/2009 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | A roof fall occured on #5 section inbetween #4 & #5 entry spad # 49721. The fall measured about 30'l x 19'w x 6-8' h. The area was bolted with 6' torque tension bolts and 12' rope bolts.The fall will... |
| 10/02/2009 | HANDTOOLS (NONPOWERED) | NO DYS AWY FRM WRK,NO RSTR ACT | None | EE was cutting a piece of rubber tape off of a buggy cable anchor and cut his index finger on his right hand. EE received 10 stitches. |
| 09/15/2009 | FALL OF ROOF OR BACK | DAYS AWAY FROM WORK ONLY | 112d lost | Employee was tramming the roof bolter forward to put up his third row of bolts. A piece of draw rock fell from the top and hit him in the left shoulder knocking him to the ground. He started missing w... |
| 09/02/2009 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | Roof Fall in track entry 3 breaks outby #1 sec. Fall was approx. 18'w x 20'lx 6-7'h. Area had fell before and was cleaned up, bolted with 5' torque tension bolts and 20' metal arch support. Area will... |
| 08/12/2009 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | A roof fall occurred on the #4 section in 3 left x-cut. The fall will not be cleaned up. The area was cribbed and dangered off. The brake thur had not been bolted before it fell. The fall was about 40... |
| 07/25/2009 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | A roof fall occurred in the #7 entry 250 feet inby spad #18010. the fall was about 20 ft wide, 40 ft long, and 8 foot high. The area was bolted with 5 foot torque tenison bolts. The fall was crib and... |