CAYUGA MINE — Accidents
Total: 267 accidents | Fatalities: 1
| Date | Classification | Injury | Days Lost | Narrative |
|---|---|---|---|---|
| 02/22/2012 | HOISTING | ACCIDENT ONLY | None | At 11:05 am the #3 went down due to the drum brakes not releasing. At 11:17 am the official notice to evacuate the mine was given and MSHA was notified. At 11:25 am the breakers were reset and the sys... |
| 07/22/2011 | HOISTING | ACCIDENT ONLY | None | # 1 hoist went down with SCR fans fault. Tried acknowledging faults but safety circuit would not clear. SCR fan was replaced with temporary and hoist was put back in service. |
| 06/30/2011 | HOISTING | ACCIDENT ONLY | None | # 3 hoist went down with a PLC issue at 5:50 am. MSHA was called at 6:10 to alert them. Evacuation was started. The evacuation was called off when the issue was resolved at 7:00 am. MSHA was notified... |
| 06/16/2011 | HOISTING | ACCIDENT ONLY | None | # 1 Hoist kicked out abruptly with multiple electrical faults. Suspected electrical issue. Repaired by fixing short in east transformer. |
| 05/23/2011 | HOISTING | ACCIDENT ONLY | None | DC loop contactor contacts arcing, burnt out bolt holding operating side of contact assembly. System ground faulted stopping the hoist. EE contacted the MSHA hotline. The mine was evacuated. A spare l... |
| 05/05/2011 | HOISTING | ACCIDENT ONLY | None | 4160 cable was hit with excavator, knocking out the power to the # 3 hoist. |
| 11/28/2010 | HOISTING | ACCIDENT ONLY | None | Moved North skip to surface for Chippy test trip. When beginning Test trip for #1 hoist would not reset. |
| 11/18/2010 | HOISTING | ACCIDENT ONLY | None | Intermittent problems with the hoist's brake caused the hoist to be shut down for a repair. The three-way valve on the SOBO Unit was replaced. |
| 10/25/2010 | SLIP OR FALL OF PERSON | DAYS RESTRICTED ACTIVITY ONLY | 30d restricted | While making a right hand turn the door of operator's pickup opened and his balance was thrown off. Grasping the wheel, as his body shifted, the truck was turned to the left and impacted a pillar. U... |
| 09/06/2010 | HOISTING | ACCIDENT ONLY | None | #1 salt hoist pinion brake failing to release properly causing the hoist to 'kick out'. The hydraulic pump was changed and the SOBO valves cleaned out. |
| 09/02/2010 | HOISTING | ACCIDENT ONLY | None | West motor blower experienced an electrical short in a junction box. |
| 08/23/2010 | HOISTING | ACCIDENT ONLY | None | SOBO was cycling rapidly, North skip loaded, hoist rolled, E-stop activated, Hoist in track limit. |
| 08/17/2010 | HOISTING | ACCIDENT ONLY | None | Sobo brake fault wouldn't reset. Tied right side Sobo control into left side UPS backup. North UPS bypassed to South UPS. |
| 08/09/2010 | HOISTING | ACCIDENT ONLY | None | Skip door wouldn't close and skip was not allowed to leave the headframe. The gate mechanism was cleaned and a build-up of material was removed. The gate closed and the system was retuned to normal... |
| 08/02/2010 | SLIP OR FALL OF PERSON | DAYS AWAY FROM WORK ONLY | 56d lost | Was at the back of the truck checking load and fell of the back--he apparently caught his leg between the back doors and crushed some tissues--x-rays show NO broken bones--He will return to work on 8-... |
| 07/26/2010 | HOISTING | ACCIDENT ONLY | None | A west drive communication fault caused the hoist to kick out. Normal reset procedures would not allow resumption of operation. Component was replaced and hoist returned to operational status. |
| 05/10/2010 | HOISTING | ACCIDENT ONLY | None | Pop off valve on the air tank, located in the #1 Hoist Pit failed. |
| 03/24/2010 | FALLING/SLIDING/ROLLING MATERIALS | FATALITY | Fatal | Employee was in dump truck waiting to be loaded with bulk salt from under 150 ton bin to transfer it to the stockpile pad on Cargill Deicing property. He was being loaded with salt when the brackets... |
| 03/24/2010 | FALLING/SLIDING/ROLLING MATERIALS | DYS AWY FRM WRK & RESTRCTD ACT | 122d lost, 6d restricted | On March 24, 2010 at approximately 6:05 pm the 150 ton bin collapsed, falling onto a truck below. Employee was in the bin operator's booth and was injured when the booth collapsed with the bin. |
| 02/23/2010 | HOISTING | ACCIDENT ONLY | None | East Autron drive communication board bad. Changed board to return to normal operations. |
| 01/26/2010 | FALL OF ROOF OR BACK | DAYS RESTRICTED ACTIVITY ONLY | 10d restricted | While scaling 1/9/2010, an employee brought down loose scale that bounced & struck his leg. First Aid was given, an 'abrasion' was reported, but no Medical Aid was sought. Two weeks later (1/26/2010)... |
| 11/09/2009 | HOISTING | ACCIDENT ONLY | None | The SOBO Unit (PLC) faulted and will not funtion. |
| 09/17/2009 | HOISTING | ACCIDENT ONLY | None | The center high voltage regulator shorted out causing one phase to 'drop out'. Our three phases motors will not operate without all three phases in operation. |
| 08/09/2009 | HOISTING | ACCIDENT ONLY | None | Electrical issue involving SCR replacement. |
| 08/03/2009 | HOISTING | ACCIDENT ONLY | None | Electrical issues with SCR modules and Amplification cards. |
| 07/29/2009 | HOISTING | ACCIDENT ONLY | None | Fault needed resetting |
| 07/17/2009 | HOISTING | ACCIDENT ONLY | None | The SRC component of the East Drive Motor failed. |
| 07/07/2009 | MACHINERY | NO DYS AWY FRM WRK,NO RSTR ACT | None | Miner was sharpening bits when the bit and tool slid off the rest. Miner's hand moved forward and struck the rotating grinding wheel, causing laceration. |
| 06/22/2009 | HOISTING | ACCIDENT ONLY | None | Hydraulic line on west Sobo brake blows. Called MSHA took initial steps to evacuate the mine. Hydraulic line replaced and conveyance back into service. |
| 05/30/2009 | HOISTING | ACCIDENT ONLY | None | A new divider, carried on work deck to where it would be installed, came into contact with another divider. Resulting damage to work deck and its disconnection from the skip. Deck wedged in the shaf... |
| 04/27/2009 | FIRE | ACCIDENT ONLY | None | An insulator on a High Voltage line failed and shorted to a lightning arrester throwing sparks into dry grass below the pole. A grass fire ensued that required the assistance of the local fire depart... |
| 02/27/2009 | HOISTING | ACCIDENT ONLY | None | New York State Electric and Gas (NYSEG) transformer blows. Power interrupted in area of mine. All power to mine lost. Evacuation started, MSHA called.Power restored at 10:37 and evacuation called o... |
| 02/19/2009 | HOISTING | ACCIDENT ONLY | None | A proximity switch on one of the gates was repaired and a test trip made. When the conveyance was brought to the upper track limit a control breaker tripped. Efforts to diagnose the problem failed t... |
| 01/12/2009 | HOISTING | ACCIDENT ONLY | None | A short across the lightning arresters on the incoming plant power caused two fuses to blow resulting in a loss of power to #1 and #3 Hoists. The mine was evacuated using the diesel generator to powe... |
| 11/05/2008 | HANDTOOLS (NONPOWERED) | NO DYS AWY FRM WRK,NO RSTR ACT | None | While dismantling exhaust equipment to facilitate the removal of an engine, a socket wrench slipped from the nut. This caused the employee's elbow to move backwards allowing it to strike a piece of an... |
| 09/22/2008 | HOISTING | ACCIDENT ONLY | None | A lug on an U/G transformer shorted out causing a GFI on surface to fail. Started evacuation. Changed GFI to get Hoist operational again. Test Trips and all OK at 1:15 a.m. Talked to James Petrie. |
| 09/04/2008 | HOISTING | ACCIDENT ONLY | None | Hoist #3 brought skip to surface landing and kicked out. Hoist controls would not reset, called MSHA, began evacuation of workers U/G. Trouble shooting revealed faulty (?) axis servo (PLC) card. Ch... |
| 08/13/2008 | HOISTING | ACCIDENT ONLY | None | Rupture in hydraulic hose on west pinion brake. Severe enough to warrant an immediate shut down to change hydraulic hose. |
| 07/24/2008 | HOISTING | ACCIDENT ONLY | None | Multiple electrical components burned up; possible power surge, shorted switch. |
| 07/21/2008 | HOISTING | ACCIDENT ONLY | None | Intermittent fault in master relay caused irregular operating conditions into next day. Second egress from mine was never compromised,'Chippy' and #3 remained available & in service.(Hoist taken out... |
| 07/10/2008 | HOISTING | ACCIDENT ONLY | None | HMI failure at #3 Hoist, would not reboot completely, hoist would not operate consistantly. Started evacuation through #1 shaft. Rebooted HMI, PLC and DHS hoist did reset, but functionality was inco... |
| 05/29/2008 | HOISTING | ACCIDENT ONLY | None | Breaker tripped. Found and fixed in PLC. |
| 05/19/2008 | HOISTING | ACCIDENT ONLY | None | Magnet switch fault (overwind). |
| 05/14/2008 | HOISTING | ACCIDENT ONLY | None | SOBO brake setting, causing breaker to trip. |
| 05/13/2008 | HOISTING | ACCIDENT ONLY | None | Underwind fault, recent hoist automation ""bugs"" being discovered and corrected. |
| 05/12/2008 | HOISTING | ACCIDENT ONLY | None | DHS mismatch, encoder would not reset |
| 03/26/2008 | HOISTING | ACCIDENT ONLY | None | #1 Hoist stopped and would not reset. UPS for the PLC system failure causing hoist to go down. UPS replaced, hoist recalibrated, reset, checked, balanced, tested OK. Two means of egress were still o... |
| 01/13/2008 | HOISTING | ACCIDENT ONLY | None | Motor starter that feeds hydraulic brake pump motor failed closed. Pump built up pressure, by-pass valve activated, dropped drum brakes (ON) stopping hoist. Men were lowered to landing and evacuated... |
| 12/21/2007 | HOISTING | ACCIDENT ONLY | None | Fuse for a fan used to cool a drive cabinet blew, which did not allow the hoist to re-set. Fuse was identified and replaced. Began evacuation of the mine, but did not complete as the down time was u... |
| 12/19/2007 | HOISTING | ACCIDENT ONLY | None | Seal in the middle of a brake drum caliper broke leading to a hydraulic leak. There are a total of 8 calipers, so braking was not affected. Since this occurred on the #3 Man Hoist, the mine was evac... |