Crown II Mine — Accidents

Total: 302 accidents | Fatalities: 0

Date Classification Injury Days Lost Narrative
07/17/2006 FALL OF ROOF OR BACK ACCIDENT ONLY None Unintentional roof fall 3ssh #6 entry belt entry xcut #2. 30' long x 18' wide x 8' high. Bolted with 6' & 8' tension rebar bolts cribs on inby rib. Will be cleaned and bolted. Was developed in Sept 20...
07/17/2006 FALL OF ROOF OR BACK DAYS AWAY FROM WORK ONLY 73d lost Man roofbolting, rock fell and hit tray, bounced and landed on his right foot. Contusion on foot, later took MRI, found broken bone. Started missing on 8/17/06.
07/17/2006 FALL OF ROOF OR BACK ACCIDENT ONLY None An unintentional roof fall occurred in #6 entry travelway between 102 and 103 xcut 2nd main east. 15' long x 16' wide x 7' high. Bolted with 6' tension rebar bolts. Will be cleaned up. Date of develop...
06/21/2006 HANDTOOLS (NONPOWERED) NO DYS AWY FRM WRK,NO RSTR ACT None Man working in plant putting a stop on a jig, wrench slipped off and hit his nose, causing a laceration that required stitches.
05/31/2006 FALL OF ROOF OR BACK ACCIDENT ONLY None Unintentional roof fall #2 entry, #13 crosscut intersection in #3 south submain, 25' long x 25' wide x 9' high. Date of development 12/14/2005. Bolted with 8' tension rebar bolts. Called in immediatel...
05/31/2006 FALL OF ROOF OR BACK ACCIDENT ONLY None Unintentional Roof fall #1 entry & #61 crosscut, 5th east panel. 25' long x 25' wide x 9' high. Date of development 2/2/06. Bolted with 8' tension rebar resin bolts.
05/29/2006 FALL OF ROOF OR BACK ACCIDENT ONLY None Roof fall crosscut #3 & #4 entry, 2nd west panel 350' mark. 30' long x 18' wide x 9' high. Date of development 5-25-05. Bolted with 6' & 8' tension rebar bolts.
04/24/2006 FALL OF ROOF OR BACK ACCIDENT ONLY None Unintentional roof fall 3rd south submain 1580' mark #4 entry 3SSM. 18' long, 35' wide and 10' high. Bolted with 6' tension rebar bolts and 8' tension rebar bolts. Mined approx. 3/21/06.
04/19/2006 FALL OF ROOF OR BACK ACCIDENT ONLY None Unintentional roof fall 3rd south sub main #10 entry #1 X cut 35' long, 18' wide, 8' high. 4 way intersection. Propped area around the fall.
03/16/2006 FALL OF ROOF OR BACK DAYS AWAY FROM WORK ONLY 6d lost Roof bolting, piece of slate fell and struck auger. Rock on auger hit EE behind right ear and right side of his face.
03/07/2006 FALL OF ROOF OR BACK ACCIDENT ONLY None UNINTENTIONAL ROOF FALL 3 NORTH SUBMAIN #4 ENTRY X-CUT 9 TO 10. 25' LONG X 18' WIDE X 6-8' HIGH. APPROX. DATE OF MINING WAS 10/1/02. BOLTED WITH 6' TR BOLTS. PROPPED OFF - WILL NOT BE CLEANED UP.
02/27/2006 FALL OF ROOF OR BACK ACCIDENT ONLY None Unintentional roof fall #29 xcut, 3rd North sub main belt line. 18' long x 18' wide x 6' high. Bolted with 5' double lock bolts. Area was mined 3-15-03. Fall was propped at approaches and will be clea...
01/18/2006 FALL OF ROOF OR BACK ACCIDENT ONLY None UNINTENTIONAL ROOF FALL 1ST WEST OFF THE 3RD SOUTH SUB MAIN ENTRY #5 480' MARK. 25'L X 19'W X 9'. AREA BOLTED WITH 6' & 8' TENSION REBAR BOLTS. 4 WAY INTERSECTION.
01/15/2006 FALL OF ROOF OR BACK ACCIDENT ONLY None UNINTENTIONAL ROOF FALL, 1ST WEST OFF 3RD SOUTH SUBMAIN, ENTRY #4. 420'MARK 4 WAY INTERSECTION. 30'LONG X 18'WIDE X 9'HIGH. BOLTED WITH 6' & 8' TR BOLTS.
01/12/2006 FALL OF ROOF OR BACK NO DYS AWY FRM WRK,NO RSTR ACT None Employee was bolting pot out. Slate fell striking him on the chin, laceration approx 2"" long received stitches. Happened in 1st West Panel.
01/11/2006 HANDLING OF MATERIALS DAYS AWAY FROM WORK ONLY 2d lost EMPLOYEE WAS RECOVERING HIGH VOLTAGE CABLE, HE PULLED ON THE CABLE & IT TIGHTENED UP, SWUNG OVER & HIT HIS RIGHT ANKLE. ANKLE SWOLLEN WITH CONTUSION.
01/06/2006 HANDLING OF MATERIALS NO DYS AWY FRM WRK,NO RSTR ACT None CHANGING #4 HOSE, THE FITTING WAS BROKEN. WHEN EMPLOYEE WENT TO PULL HOSE OUT THE BROKEN FITTING CUT HIS LEFT HAND, RECEIVED STITCHES.
01/06/2006 MACHINERY NO DYS AWY FRM WRK,NO RSTR ACT None ROOF BOLTING & WRENCH KICKED OUT OF DRILL BOX & HIT EMPLOYEE ABOVE HIS RIGHT EYE, RECEIVED STITCHES.
01/03/2006 FALL OF ROOF OR BACK ACCIDENT ONLY None UNINTENTIONAL ROOF FALL IN 3SSM #2 ENTRY 1080' MARK. 20' L X 20' W X 10' H. BOLTED WITH 8 TR BOLTS, PROPED OFF TO WALK NEXT ENTRY OVER IN RETURN.
12/23/2005 SLIP OR FALL OF PERSON DAYS AWAY FROM WORK ONLY 123d lost EE SLIPPED ON SLATE AND COAL WHILE FILLING WATER TANK ON THE MAINTENANCE VEHICLE FOR FILLING BATTERIES. EE FELL DOWN UNDER THE VEHICLE AND HURT HIS RIGHT HIP AND RIGHT SHOULDER - LOWER BACK PAIN. IN...
12/06/2005 SLIP OR FALL OF PERSON DAYS AWAY FROM WORK ONLY 73d lost Was roof bolting #5 entry 5th East, tripped over rock and fell on left knee, pain in left knee also strain to groin. Started missing 1-30-06 for procedure on knee.
10/20/2005 FALL OF ROOF OR BACK ACCIDENT ONLY None Unintentional roof fall in the 5th east panel occurred at crosscut located at 1380 ft survey station between entries 3 and 4. The fallen material measured 20 x 13 x 6 feet. The support methaod used wa...
10/19/2005 FALL OF ROOF OR BACK ACCIDENT ONLY None Unintentional roof fall in the 5th east panel. Fall occurred in crosscut by survey station 1620. It was between entries 6 and 7. The loose material measured 20 x 18 x 6 feet. The method of support was...
10/19/2005 FALL OF ROOF OR BACK ACCIDENT ONLY None Unintentional roof fall in 5th east panel occurred in crosscut 23 between the #8 and #9 entries. The area had been supported with 6' tension rebar bolts. The fallen material measured 30 x 18 x 6 feet.
09/29/2005 FALL OF ROOF OR BACK ACCIDENT ONLY None Unintentional roof fall occurred in the 2nd main east #3 entry in intersection nine crosscut 85. The rock consisted of slate and layered rock measuring 30' x 18' x 9'. The date of development is 7/10/...
09/22/2005 FALL OF ROOF OR BACK ACCIDENT ONLY None UNINTENTIONAL ROOF FALL IN 2ND MAIN EAST SECTION. ENTRY #6 AT INTERSECTION WITH #190 CROSSCUT. 22'X20' AREA WITH A HEIGHT OF 10' FOR THE AMOUNT OF FALLEN MATERIAL. THE SUPPORT METHOD WAS 8'TR BOLTS.
09/17/2005 FALL OF ROOF OR BACK ACCIDENT ONLY None UNINTENTIONAL ROOF FALL, XCUT BETWEEN #2 AND #3 SEALS AT THE 1N5M OFF 2ME. BOLTED WITH 6' TR BOLTS 20'L X 16W X 6'H. DATE OF DEVELOPMENT JAN. 1991. PROPPED APPROACH TO FALL.
09/15/2005 HANDLING OF MATERIALS NO DYS AWY FRM WRK,NO RSTR ACT None Changing top roller on clean coal collecting belt, man had roller dropped on his right hand. Injured right ring finger, fracture.
08/31/2005 HANDLING OF MATERIALS NO DYS AWY FRM WRK,NO RSTR ACT None Working on roof bolting loading bolts, mashed his right little finger. Received laceration, went to hospital, received 3 stitches.
08/19/2005 FALL OF ROOF OR BACK ACCIDENT ONLY None Unintentional roof fall # 32 x-cut 2ME between #6 & #5 Entry. 60 ft. long X 20 ft. wide X 10 ft. High. Developed Mar of 1990. Was bolter with 6 ft tension rebar bolts. Not in intersection - proped - w...
08/05/2005 FALL OF ROOF OR BACK ACCIDENT ONLY None UNINTENTIONAL ROOF FALL. X-CUT #21, 3 EP, #3 ENTRY. 25' LONG X 25' WIDE 8' HIGH. 4-WAY INTERSECTION. MINED 3-8-05 AND BOLTED WITH 8' TR BOLTS. PROPED AROUND. NOT GOING TO CLEAN UP.
07/31/2005 FALL OF ROOF OR BACK ACCIDENT ONLY None Unintentioned roof fall 3rd east panel #4 and #5 entry and crosscut between the two entries 4 way intersection 2250' mask. bolted with 8' tr bolt, approx. date of development 5-05 25'x 85' w x 9' high...
07/26/2005 SLIP OR FALL OF PERSON DAYS AWAY FROM WORK ONLY 12d lost At the 3EP filter bank man slipped in mud and twisted left knee. Started missing 10-11-05.
07/25/2005 FALL OF ROOF OR BACK ACCIDENT ONLY None UNINTENTIONAL ROOF FALL #6 ENTRY MAIN NORTH TRAVELING #36 X-CUT. 60' LONG X 20' WIDE X 10' HIGH. BOLTED WITH 8' TR BOLTS, PROPS AND CRIBS. 4-WAY INTERSECTION. OPEN DATE OF DEVELOPMENT 1-84.
07/23/2005 FALL OF ROOF OR BACK DAYS AWAY FROM WORK ONLY 26d lost Employee was driving down 2nd main east travelway xcut 170. A piece of clod fell down between pins and struck his left shoulder. Started missing on 10/01/05.
07/07/2005 FALL OF ROOF OR BACK ACCIDENT ONLY None Unintentional roof fall in 3EP #6 entry survey station 3930' to 3990' mmu #010-0. method of roof control in area 6' TR bolts & 8' TR bolts in the intersections. 70'L x 30'W x 11'H in intersections. Ap...
07/01/2005 FALL OF ROOF OR BACK ACCIDENT ONLY None Unintentional roof fall in 3rd east panel 3920' survey station 4 & 5 entry. 30'L x 18'W x 6.5'H. Method of roof control 6' bolts. Mmu 050-0. Approx. date of development 6/27/05.
06/24/2005 FALL OF ROOF OR BACK ACCIDENT ONLY None Unintentional roof fall took place in the third east panel between #2 and #3 entries at the 3630' mark. 6' tension bolts were the support in the fall area. The fall dimensions are 15' x 12' x 6' 1/2
06/23/2005 HANDLING OF MATERIALS DAYS AWAY FROM WORK ONLY 36d lost Employee was pushing cable through shieve. Cable was twisted and his left shoulder was twisted. He started missing on 9/29/05.
06/23/2005 FALL OF ROOF OR BACK ACCIDENT ONLY None Fall occurred in the 30th crosscut in the #8 entry of the third east panel. Supported by 8' and 6' tension rebar pins. The fall blocked the travelway. Trafic was diverted and the area propped. Fall di...
06/18/2005 FALL OF ROOF OR BACK ACCIDENT ONLY None Unintentional roof fall x cut #6 & #7 5543' mark 1st east panel 25' x 18' w x 5' high bolted with 4' cov. mned spark 5/18/05.
06/13/2005 SLIP OR FALL OF PERSON DAYS AWAY FROM WORK ONLY 20d lost Man working on coal hauler 3EP unit, went to get down and twisted his left knee. Started missing 8-17-05.
06/12/2005 FALL OF ROOF OR BACK ACCIDENT ONLY None Unintentional roof fall 1st east panel #5 entry. 5536': 25'L x 35'W x 5'H. 4-way intersection. Bolted with 4' roof bolts. Mined 6/1/05.
05/30/2005 FALL OF ROOF OR BACK ACCIDENT ONLY None Unintentional roof fall, fall took out senser on 5-28-05 4:11 a.m., but no one in the mine until 5-30-05. Fall 3 EP #4 entry Xcut #33 25' l by 20' w by 10' h. 4-way intersection bolted with 8' TR bolt...
05/21/2005 FALL OF ROOF OR BACK NO DYS AWY FRM WRK,NO RSTR ACT None Man bolting in the 1 EP unit. Slate slid down the bolter area hitting him on the forehead causing a laceration about 1"" long. No lost time, he reveived stitches.
05/18/2005 MACHINERY DAYS AWAY FROM WORK ONLY 149d lost Employee was bolting to reinforce intersection 3rd East Panel, #4 entry 2970'. Using spiral auger pulling it out of the hole, he hit rotation, broke his left arm just above his wrist & dislocated his...
05/16/2005 FALL OF ROOF OR BACK ACCIDENT ONLY None Unintentional roof fall 3rd east panel #3 entry 35 xcut. 40'L x 24'W x 9'H. Mined 4/13/05. 4way intersection bolted with 6' or 8' TR bolts.
05/14/2005 FALL OF ROOF OR BACK ACCIDENT ONLY None UNINTENTIONAL ROOF FALL 3RD EAST PANEL #3 ENTRY 2910' MARK. 30'L X 30'W X 8'H, 4WAY INTERSECTION MMU 050-0, MINED 5/12/05. BOLTED WITH 6'TR and 8' TR BOLTS.
05/12/2005 HANDLING OF MATERIALS DAYS AWAY FROM WORK ONLY 86d lost Worker was on the bottom lifting a 5 gallon can of oil. He felt pain in his left arm & shoulder. Torn rotator cuff, started missing on 5/14/05.
05/06/2005 FALL OF ROOF OR BACK ACCIDENT ONLY None UNINTENTIONAL ROOF FALL, #2 ENTRY 3 EP 2850' INBY THE LOADING POINT MMU 050-0 25'L X 35'W X 8', 4 WAY INTERSECTION. PARTIALLY CLEANED UP TO ALLOW GAS CHECKS FOR X-CUT TO GO THROUGH THEN COMPLETELY PRO...