Darby Mine — Accidents
Total: 241 accidents | Fatalities: 1
| Date | Classification | Injury | Days Lost | Narrative |
|---|---|---|---|---|
| 04/03/2024 | HANDLING OF MATERIALS | DAYS AWAY FROM WORK ONLY | 5d lost | Employee was unloading an electric motor and motor flipped from pallet and struck their leg. |
| 07/25/2023 | HANDLING OF MATERIALS | DAYS AWAY FROM WORK ONLY | 73d lost | Cleaning Rock off of the Continuous Miner. |
| 01/19/2023 | HANDLING OF MATERIALS | NO DYS AWY FRM WRK,NO RSTR ACT | None | Employee and Co-worker were removing rock off continuous miner. As EE was removing the rock, the rock slipped pinning EE's finger against another rock which resulted in a laceration to a finger on EE'... |
| 06/20/2022 | OTHER | DAYS AWAY FROM WORK ONLY | 69d lost | Employee was rock dusting the face of the entry by hand. The employee was in a bent over position, as they moved backwards they came to an area where the roof was higher. When the employee stood uprig... |
| 03/20/2022 | FALL OF ROOF OR BACK | FATALITY | Fatal | The employee and co-workers were in the No.8 entry at x-cut No.47 on the 3 South Mains preparing to remove a permanent stopping. The injured employee was in the process of walking outby to turn off a... |
| 12/14/2021 | SLIP OR FALL OF PERSON | DAYS AWAY FROM WORK ONLY | 130d lost | The employee was stepping off the mantrip and twisted Rt. Knee. |
| 10/01/2021 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | The roof fall occurred in the No. 5 entry between X-cut No. 26 and x-cut No. 27 on the DS-2 mains. The roof fall is confined to the No. 5 entry. The fall is approximately 12' long, 10' wide, and 5' th... |
| 10/01/2021 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | The roof fall happened in the No.4 intake entry at x-cut No. 28 on the DS-2 mains. The roof fall is approximately 30' Long, 19' Wide, and 8' thick/high. Ventilation was not affected. The primary escap... |
| 09/15/2021 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | On 9/15/2021 a roof fall occurred in the No. 3 beltline entry at x-cut No. 56 on the DS-1 mains. The roof fall is confined to the No. 3 entry. The roof fall is approximately 30' in length X 19' wide a... |
| 08/09/2021 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | At 8:20 pm section foreman encountered a roof fall outby the MMU 005 in No. 5 Return Air Course Entry between x-cut No. 28 and x-cut 27 on the DS-2 Mains where the No. 5 entry of the DS-7 Panel was st... |
| 06/18/2021 | MACHINERY | DAYS RESTRICTED ACTIVITY ONLY | 6d restricted | EE was installing a roof bolt and when EE raised the drill pot, to attach the wrench to the bolt head, the bolt caught and bent, mashing EE's pinky finger to the frame of the drill head. |
| 06/11/2021 | SLIP OR FALL OF PERSON | NO DYS AWY FRM WRK,NO RSTR ACT | None | Employee was patching a hole in a brattice. While packing brattice block employee slipped on the mine floor and felt a sharp pain in lower back. Employee did not go to the doctor the date of the accid... |
| 04/24/2021 | HANDLING OF MATERIALS | DAYS AWAY FROM WORK ONLY | 71d lost | The employee was shoveling around the section tailpiece and felt a sharp pain in lower back. |
| 04/09/2021 | HANDLING OF MATERIALS | DAYS AWAY FROM WORK ONLY | 78d lost | Employee was removing a guard from the transfer jack off of a ram car, and when they lifted the guard they strained their lower back. Employee finished the shift and went to a local clinic for medical... |
| 01/20/2021 | HANDLING OF MATERIALS | NO DYS AWY FRM WRK,NO RSTR ACT | None | Employee was replacing the guard over the tail shaft on a feeder. The guard slipped and caught the employee's left hand resulting in a simple fracture on EE's index finger. The employee did not go to... |
| 10/08/2020 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | An unplanned roof fall occurred at the intersection of crosscut 27 on the DS-5 Panel of the 005 MMU in the #4 intake entry. The fall was approximately 30' in length, 20' in width, and 8' to 10' in thi... |
| 08/14/2020 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | A Non-Injury Roof Fall occurred in the outby area of the mine. The Roof Fall is located in the No. 1 entry between x-cuts No. 9 & 11 of the DS-1 Panel. The Roof Fall is approximately 20'ft. wide x 70'... |
| 05/13/2020 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | A Non-Injury Roof Fall occurred between the No. 4 & No. 5 entries at crosscut No. 22 on the 005-0 MMU on the DS-5 Panel. The roof fall was found during the weekly exam. MSHA was notified about the roo... |
| 03/18/2020 | HANDLING OF MATERIALS | NO DYS AWY FRM WRK,NO RSTR ACT | None | EMPLOYEE WAS DROPPING WORK BASKET IN THE LOCKER ROOM WHEN IT SLIPPED CUTTING RIGHT PINKY FINGER REQUIRING 4 STITCHES. |
| 03/09/2020 | HANDTOOLS (NONPOWERED) | PERM TOT OR PERM PRTL DISABLTY | None | EMPLOYEE WAS WORKING ON A RAM JACK PIN. WHEN EE WAS LINING UP THE PIN EE'S RIGHT INDEX FINGER WAS AMPUTATED JUST ABOVE EE'S MIDDLE KNUCKLE ON EE'S RIGHT HAND. |
| 02/09/2020 | SLIP OR FALL OF PERSON | DAYS AWAY FROM WORK ONLY | 9d lost | employee was picking up a box of glue off of the scoop stepped in a hole and felt pain in EE's lower back |
| 02/08/2020 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | A non-injury roof fall occurred in the No. 1 entry at x-cut No.21 on the 005-0 MMU. Roof Fall size approx.20'ft. x 20'ft x 6'-7'ft. thick. The fall will be cleaned up and roof re-supported. (No injuri... |
| 02/04/2020 | HANDLING OF MATERIALS | DAYS AWAY FROM WORK ONLY | 84d lost | EMPLOYEE WAS PUTTING A LID BACK ON THE MINER WHEN THEY FELT PAIN IN RIGHT ELBOW. |
| 01/10/2020 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | THE ROCK FALL OCCURRED ON THE 005 SECTION AROUND 11:45 AM IN THE #5 HEADING CROSS CUT (16) 20 FOOT OUT BY THE FACE FALLING ON THE ROOF BOLTER. NO ONE WAS INJURED. THE FALL MEASURED 18 X 30 X 6 FOOT TH... |
| 11/11/2019 | HANDTOOLS (NONPOWERED) | NO DYS AWY FRM WRK,NO RSTR ACT | None | EMPLOYEE WAS CLEANING ROCK OFF THE MINER WITH A SHOVEL WHEN LEFT FOREARM CAME IN CONTACT WITH A SHARP PIECE OF ROCK CAUSING A LACERATION THAT REQUIRED 7 STITCHES, NO LOST WORK DAYS. |
| 05/02/2019 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | The accident was an unplanned roof fall |
| 05/11/2018 | POWERED HAULAGE | DAYS AWAY FROM WORK ONLY | 60d lost | EE was riding in mantrip & hit a bump on a section of muddy roadway jarring ee neck. EE started missing work on 5/15/18. |
| 12/11/2017 | FALL OF ROOF OR BACK | NO DYS AWY FRM WRK,NO RSTR ACT | None | Employee was installing straps & bolting in #1 entry. When a rock fell striking employee in face & head. Employee had stitches on the nose & scratch on the cornea. |
| 11/15/2017 | POWERED HAULAGE | DAYS AWAY FROM WORK ONLY | 12d lost | Battery end operator side tire was coming apart, tramming car to repairman & a flapper tore fender off & came in deck, hit left arm in bicep area. |
| 08/08/2017 | FALL OF ROOF OR BACK | NO DYS AWY FRM WRK,NO RSTR ACT | None | While moving cut ends from timbers, the employee picked up a timber end and a piece of draw rock fell striking EE on the right forearm and wrist causing a laceration on the arm requiring sutures. |
| 08/07/2017 | POWERED HAULAGE | NO DYS AWY FRM WRK,NO RSTR ACT | None | While backing up a 4 man ride, the employee caught ee left foot between the ride and a crib resulting in a fracture to the left heel. |
| 08/07/2017 | SLIP OR FALL OF PERSON | NO DYS AWY FRM WRK,NO RSTR ACT | None | While employee was repositioning the roof bolter head to install the next bolt ee stepped over toward the drill station when right knee popped. EE was diagnosed with a torn meniscus that will require... |
| 07/28/2017 | SLIP OR FALL OF PERSON | NO DYS AWY FRM WRK,NO RSTR ACT | None | Employee was walking back from the feeder to their car when they twisted their right knee. Employee was diagnosed with a torn meniscus. |
| 07/16/2017 | POWERED HAULAGE | NO DYS AWY FRM WRK,NO RSTR ACT | None | Employee was taking bottom belt structure loose while the belt was running. A belt splice hit a bottom hanger and moved it striking the employee on the left arm and wrist causing a contusion. The em... |
| 10/24/2016 | FALL OF ROOF OR BACK | DAYS AWAY FROM WORK ONLY | 82d lost | While moving the roof bolter, a piece of roof rock measuring 13"" x 15"" by 2"" in thickness fell striking employee's hard hat causing the hat to slide down employee's face. Employee sought medical at... |
| 09/13/2016 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | A roof fall was discovered on this date in a bleeder entry. The fall was located in the wall entry between the L4 and L5 panels in the bleeder. The area was previously supported with 6' torque tensio... |
| 09/12/2016 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | A roof fall was discovered on this date. The fall was located in the #1 entry extending into the crosscut at crosscut 16 of the 2-Left Panel off 6-West. The fall measured 18' by 30' and was 10' in t... |
| 09/06/2016 | DISORDERS (REPEATED TRAUMA) | OCCUPATNAL ILLNESS NOT DEG 1-6 | None | Employee sought medical attention on this date after months of reoccurring pain in lower back. An MRI was obtained and the results shows that Employee has degenerative disc disease from L3-L4 to L5-S... |
| 08/08/2016 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | A roof fall was found on this date during weekly exams. The fall was located on the 2-North Mains at crosscut #50 in the #6(Intake) entry. The fall measured 20' by 20' and was 5' in thickness. The... |
| 07/18/2016 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | A roof fall was discovered on this date. The fall was located on the 2 Left panel at crosscut #22 in the #1 entry. The fall measured 70' by 18' and was 8' in thickness. The areas was previously sup... |
| 07/18/2016 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | A roof fall was discovered on this date. The fall was located in the #1 entry of the 2-Left Panel on MMU 003. The fall measured 20' by 30' and was 8' in thickness. The area was previously supported... |
| 05/10/2016 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | A roof fall was discovered on this date during weekly exams. The fall was located in the #1 entry of the Lower 3-Left Bleeder. The fall measured 18' by 20' and was 6-8' in thickness. The area was da... |
| 04/26/2016 | SLIP OR FALL OF PERSON | DAYS AWAY FROM WORK ONLY | 8d lost | As worker was helping align a feeder during a set up, went around the feeder to look at the alignment. As EE walked around the feeder, slipped and fell striking chest on a crib block that caused a c... |
| 04/20/2016 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | A roof fall was discovered on this date. The fall was located in the #3 entry of 3-North-2 roadway at cc #73. The fall measured 20' by 50' and was 10' in thickness. The area was originally supported... |
| 12/05/2015 | DISORDERS (REPEATED TRAUMA) | OCCUPATNAL ILLNESS NOT DEG 1-6 | None | On this date, employee reported that he had been suffering back pain. He sought medical advice and began missing work on 12/7/2015 to seek treatment. Results of a MRI shows anterolisthesis and degen... |
| 10/16/2015 | HANDLING OF MATERIALS | NO DYS AWY FRM WRK,NO RSTR ACT | None | Employee was taking a belt spreader our during a belt pull back when he felt pain in his right bicep. He continued working and sought medical treatment on 11/03/2015 for a surgical procedure on a ten... |
| 10/07/2015 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | A roof fall was discovered on this date. The fall was located in a crosscut at break #10 between the #4 and #5 entries, on L-3 left panel. The fall measured 20' by 20' and was 8' in thickness. The... |
| 09/16/2015 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | A roof fall was discovered in the #5 entry of 3-Left paned on 003 section between crosscuts 17 and 18. The fall measured 20' by 40' and was 8' in thickness. The area was originally supported with 6'... |
| 09/03/2015 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | A roof fall was discovered on this date. The fall measured 20' by 30' and was 10' in thickness. The fall was located on 3-Left Panel in the #1 Entry at Crosscut #3. The area was originally supporte... |
| 05/19/2015 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | A roof fall occurred on this date. The fall was located on the 005 section while retreat mining was taking place. The fall measured 20' by 20' and was 8' in thickness and was located in the #4 entry... |