| 11/02/2000 | HANDTOOLS (NONPOWERED) | NO DYS AWY FRM WRK,NO RSTR ACT | None | FRACTURE OF FIRST JOINT ON LEFT HAND LITTLE FINGER, WHILE HAND MINING WITH SCALING BAR FROM BASKET IN BOOM TRUCK, PINCH POINT BETWEEN BASKET AND SCALING BAR. |
| 10/27/2000 | HANDLING OF MATERIALS | DAYS AWAY FROM WORK ONLY | 1d lost | REPORTABLE: EMPLOYEE STATED ALLEGED LOSS OF CONSCIOUSNESS. EMPLOYEE WAS UNROLLING STEEL FENCE BY KICKING THE ROLL. HE FELT A SHARP PAIN IN LOWER BACK. |
| 08/28/2000 | HOISTING | ACCIDENT ONLY | None | HOIST LOST POWER AT 3:10 PM AND ELECTRICIANS WERE CALLED TO REPAIR IT. MSHA WAS CALLED AT 3:23PM AND TOLD THAT #31 HOIST AT FLETCHER WAS OUT OF SERVICE. THE ELECTRICIANS FOUND ALL AUXILLARY C ONTACT T... |
| 06/30/2000 | FIRE | ACCIDENT ONLY | None | A MINE FIRE OCCURRED IN AN AREA ADJACENT TO THE UNDERGROUND SHOP. THE MINE WAS EVACUATED WITH 17 MINERS BEING EVACUATED FROM THE WEST FORK SHAFT AND 7 MINERS, INCLUDING 5 CONTRACT MINERS, WER E EVACUA... |
| 06/27/2000 | HOISTING | ACCIDENT ONLY | None | HOIST STARTED PULLING HIGH AMPS AND CONTACTOR BURNED UP ON THE LOWER SIDE IN THE MOTOR CONTROL CENTER. ELECTRICIANS WERE CALLED TO REPAIR HOIST AND HOISTMAN CALLED MSHA 11:40 AM, HOIST WAS REP AIRED A... |
| 06/26/2000 | HOISTING | ACCIDENT ONLY | None | DURING AN INSPECTION OF HOIST BY SURFACE SHOP, THEY TRIPPED A SLACK ROPE SWITCH TO TEST IT & IT WOULD NOT RESET. MSHA WAS CALLED AT 4 P.M. & ELECTRICIANS CHECKED THE SWITCH, REPAIRS WERE MADE & MSHA W... |
| 06/26/2000 | HOISTING | ACCIDENT ONLY | None | HOISTMAN LOST BRAKE PRESSURE ON AUTOMATIC, BUT COULD RUN ON MANUAL SURFACE SHOP THE HYDRAULIC TANK & CLEANED THE SCREENS. MSHA WAS CALLED AT 9:40 A.M. AND TOLD HOIST WAS DOWN. AFTER MAINTENA NCE WAS C... |
| 06/02/2000 | HOISTING | ACCIDENT ONLY | None | TWO EMPLOYEES SENT A NEW MUCK BUCKET UNDERGROUNDON NORTH SIDE OF #30 SHAFT. THE BUCKET HUNG UP ABOUT 70' DOWN & CAUSED HOIST TO KICK OUT SLACK ROPE SWITCH. TWO CENTRAL SERVICE MAINTENANCE MEN WENT DOW... |
| 05/25/2000 | HOISTING | ACCIDENT ONLY | None | HOISTMAN WAS RUNNING HOIST BEFORE SHIFT STARTED AND LOST POWER. CALLED ELECTRICIANS, MSHA WAS CALLED AT 7:30 AM TO REPORT HOIST DOWN. ELECTRICIANS FOUND FAULTY BRAKE WEAR LIMIT SWITCH AND REPL ACED IT... |
| 04/08/2000 | HOISTING | ACCIDENT ONLY | None | #31 HOIST LOST POWER DUE TO A FAULTY BACKOUT SWITHC. HOIST WENT DOWN AT 6:35 AM. HOISTMAN CALLEDWESTFORK MINE HOISTMAN AT 6:45 FOR BACKUP & CALLED MSHA AT 7AM & REPORTED HOIST DOWN. ELECTRICIA NS REPA... |
| 03/28/2000 | ENTRAPMENT | ACCIDENT ONLY | None | #31 HOIST LOST CONTROL POWER AT APPROX 10:25 AM.CALLED MSHA AT 10:47AM. CALLED WEST FORK MINE 10:45 AM AND TOLD THEM HOIST WAS DOWN AND WE HAD TWO MEN ON CAGE. WE MADE RADIO CONTACT WITH THESE MEN & E... |
| 03/13/2000 | HOISTING | ACCIDENT ONLY | None | AT 12:40 PM ELECTRICIANS LOCKED OUT #31 HOIST SO MAINTENANCE COULD PEFORM A SCHEDULED GEAR OIL CHANGE AND TH EHOISTMAN CALLED MSHA AT 12:55 AND TOL DTHEM HOIST WAS DOWN. MAINTENANCE WAS COMPL ETED AND... |
| 03/07/2000 | HOISTING | ACCIDENT ONLY | None | #30 HOIST WENT DOWN AND MSHA WAS CALLED AT 10:08AM. ELECTRICIANS AND MECHANICS REPLACED CHECK VALVES BETWEEN BRAKE PUMPS AND RETURNED HOIST TO SERVICE AT 2:18 PM SAME DAY. MSHA WAS CALLED AT T HAT TIM... |
| 02/24/2000 | HOISTING | ACCIDENT ONLY | None | #31 HOIST LOST POWER IN DOWN POSITION. CALLED ELECTRICIANS AND THEY INSTALLED A NEW COIL IN CONTACTOR. MSHA WAS CALLED AT 10:00 A.M. WEST FORK HOISTMAN WAS CALLED FOR BACK UP AT 9:55 A.M. AFTE R HOIST... |
| 02/22/2000 | HOISTING | ACCIDENT ONLY | None | HOIST BRAKE WOULD NOT RELEASE. CALLED ELECTRICIAN AND HE INSTALLED A NEW BRAKE WEAR LIMIT SWITCH. MSHA WAS CALLED AT 8:50 P.M. WEST FORK MINE WAS CALLED AT 8:55 P.M. HOIST WAS RETURNED TO SERV ICE AT... |