Harvey Mine — Accidents
Total: 251 accidents | Fatalities: 0
| Date | Classification | Injury | Days Lost | Narrative |
|---|---|---|---|---|
| 07/22/2020 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | An unintentional roof fall occurred in 7 North Mains 29 to 30 Wall #1 Entry. There were no injuries or damaged equipment as a result of this incident. Conditions contributing to the roof fall are adve... |
| 07/06/2020 | HOISTING | ACCIDENT ONLY | None | The BMX slope hoist was taken out of service when the ABB drive malfunctioned. The ABB drive was repaired and the hoist went back into service. |
| 06/28/2020 | HOISTING | ACCIDENT ONLY | None | The BMX slope hoist was taken out of service when the brake sensor alarm malfunctioned. The brake sensor alarm was repaired and the hoist went back into service. |
| 06/17/2020 | HOISTING | ACCIDENT ONLY | None | The elevator at BMX portal was out of service due to the brake drum release solenoid malfunctioning. The solenoid was replaced and the elevator returned to service. |
| 06/16/2020 | HOISTING | ACCIDENT ONLY | None | The 1A Capsule at the 1A shaft was out of service due to a malfunction with the lightning arrester for the cable to the bottom landing switch. The lightning arrester was replaced and the capsule ret... |
| 06/04/2020 | FALL OF FACE/RIB/PILLAR/SIDE/HIGHWALL | DAYS AWAY FROM WORK ONLY | 305d lost | Employee was rib bolting on the right side of the 4B miner. While drilling a piece of rock / coal came out of the rib and struck the employee. Employee received seven sutures to the left side of head. |
| 04/06/2020 | HOISTING | ACCIDENT ONLY | None | The BMX slope hoist was taken out of service due to a malfunction with the overspeed sensor. The control was reprogrammed and the hoist went back into service. |
| 02/27/2020 | HOISTING | ACCIDENT ONLY | None | The 1A Capsule at the 1A shaft was out of service due to a malfunction with the bottom landing switch. The switch was replaced and the capsule returned to service. |
| 01/06/2020 | HANDTOOLS (NONPOWERED) | DAYS AWAY FROM WORK ONLY | 54d lost | Employee was setting posts and swinging a sledge hammer and felt pain in lower abdomen. Employee did not miss work until 1/27/2020 when it turned out that employee needed surgery for a hernia. |
| 01/06/2020 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | An unintentional roof fall occurred in 3 North Mains 13 to 13 1/2 Wall #0 Entry. There were no injuries as a result of this incident. Conditions contributing to the roof fall are adverse roof conditio... |
| 12/27/2019 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | An unintentional roof fall occurred in 7N Mains at 44 Wall #6 Entry. There were no injuries or damaged equipment as a result of this incident. Conditions contributing to the roof fall are adverse geol... |
| 11/25/2019 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | An unintentional roof fall occurred in 5B TG section at 10 Wall #2 Entry Intersection. There were no injuries or damaged equipment as a result of this incident. Conditions contributing to the roof fal... |
| 10/01/2019 | SLIP OR FALL OF PERSON | DYS AWY FRM WRK & RESTRCTD ACT | 42d lost, 5d restricted | The injured employee attempted to cross a supply car when EE rolled EE's right ankle on the car, causing EE to trip and fall. EE landed on the same ankle EE twisted on the supply car. |
| 09/22/2019 | HANDLING OF MATERIALS | DAYS RESTRICTED ACTIVITY ONLY | 12d restricted | Coworker was removing conveyor belt roller from frame when roller broke and struck the conveyor belting material that was pulled up to provide slack for conveyor belt splicing. The impact caused the s... |
| 09/14/2019 | POWERED HAULAGE | NO DYS AWY FRM WRK,NO RSTR ACT | None | Employee was sumping the miner in when a 12"" cc bolt sprung loose off of the top of the miner, striking the employee in the mouth chipping EE's front two teeth. |
| 08/23/2019 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | An unintentional roof fall occurred in 5B HG miner section 27 Wall #2 Entry Intersection. There were no injuries as a result of this incident. Conditions contributing to the roof fall are adverse geol... |
| 08/16/2019 | HOISTING | ACCIDENT ONLY | None | The BMX slope hoist was taken out of service when the brakes on the brake car locked up. The brake contactor malfunctioned and was replaced and the hoist went back into service. |
| 08/14/2019 | FALL OF ROOF OR BACK | DAYS RESTRICTED ACTIVITY ONLY | 8d restricted | Employee was operating a gopher drill on the 5A Section belt when a piece of rock came from the mine roof and struck employee's right hand causing a laceration to the right middle finger. Employee re... |
| 07/25/2019 | HOISTING | ACCIDENT ONLY | None | The 1A capsule at the 1A Shaft was out of service due to a malfunction with the PLC processor. The PLC processor had internal switches that became non-operational, the PLC processor was replaced and... |
| 07/24/2019 | SLIP OR FALL OF PERSON | NO DYS AWY FRM WRK,NO RSTR ACT | None | Employee was exiting a Brookeville mantrip when employee stepped on the rail causing employee to slip and fall. The employee's face area struck the side of the mantrip during the fall causing a lacer... |
| 07/22/2019 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | An unintentional roof fall occurred in 6A miner section 2 Wall #4 Entry on the solid side of the intersection. There were no injuries as a result of this incident. Conditions contributing to the roof... |
| 07/15/2019 | HOISTING | ACCIDENT ONLY | None | The elevator at BMX portal was out of service due to the brake pump malfunctioning. The brake pump was replaced and the elevator returned to service. |
| 07/08/2019 | HANDLING OF MATERIALS | DAYS AWAY FROM WORK ONLY | 92d lost | Employee was rib bolting on the left side of the miner in 5B TG. EE grabbed a roof strap from the top of the miner and flipped it so EE could slide it over to the right side of the miner. EE's right p... |
| 06/26/2019 | FALL OF ROOF OR BACK | ALL OTHER CASES (INCL 1ST AID) | None | CB Mining employee was assisting with the assembly of an Armored Face Conveyor Chain on the head gate. While in a prone position a rock approx. 24"" X 18"" X 3"" dislodged from the roof and fell appr... |
| 06/18/2019 | HANDTOOLS (NONPOWERED) | DAYS AWAY FROM WORK ONLY | 63d lost | Employee was using a come-along to move the outby end of the 5B HG tail piece. The Come-Along was hooked to a 5/16 chain that was secured in a belt clip. The chain broke causing the employee to fall b... |
| 06/05/2019 | HOISTING | ACCIDENT ONLY | None | The BMX slope hoist was taken out of service during an MSHA inspection for a broken center left brake assembly's inby guide spool. This condition is in conjunction with MSHA citation #9078996. The MSH... |
| 06/03/2019 | SLIP OR FALL OF PERSON | DAYS AWAY FROM WORK ONLY | 280d lost | Employee was hanging communication cable along 7 North Track, when EE tripped on a track tie and fell on EE's left hand. The incident resulted in a fracture to the left pinky finger. |
| 05/22/2019 | HOISTING | ACCIDENT ONLY | None | The elevator at BMX portal was out of service due to the bottom door sensors malfunctioning. The sensors and the door track were cleaned and the elevator returned to service. |
| 03/28/2019 | MACHINERY | DAYS AWAY FROM WORK ONLY | 122d lost | Employee was trying to remove a cable bolt that was stuck in the roof, while the employee tried to pull the bolt from the roof while reversing the head of the drill the bolt head struck EE in the left... |
| 03/08/2019 | HOISTING | ACCIDENT ONLY | None | The elevator at BMX portal was out of service due to the door track for the bottom door breaking. The door track and alignment was fixed and the elevator returned to service. |
| 02/22/2019 | HOISTING | ACCIDENT ONLY | None | The 1A capsule at the 1A shaft was out of service due to a malfunction with the brakes properly opening. The brake switch was properly adjusted and returned to service. |
| 02/09/2019 | HOISTING | ACCIDENT ONLY | None | The elevator at BMX portal was out of service due to a malfunction of the top landing switch. The switch was fixed and the elevator returned to service. |
| 02/08/2019 | HANDLING OF MATERIALS | NO DYS AWY FRM WRK,NO RSTR ACT | None | Employee was hooking up with rope to separate pan and got hand caught between rope and pan causing injury. |
| 01/21/2019 | HOISTING | ACCIDENT ONLY | None | The elevator at Patterson Creek portal was out of service due to the limit switch on the cage malfunctioning. The switch was replaced and the elevator returned to normal service. |
| 01/10/2019 | HANDLING OF MATERIALS | DAYS AWAY FROM WORK ONLY | 34d lost | Employee was moving the cable reel cover back into place on the mule when they pinched their left middle finger between the mule and the cover. Fracture to the left middle finger. |
| 12/05/2018 | HOISTING | ACCIDENT ONLY | None | The BMX slope hoist was out of service due to the gearbox for the encoder breaking. The gearbox was replaced and the hoist returned to service. |
| 12/03/2018 | IGNITION OR EXPLOSION OF GAS OR DUST | ACCIDENT ONLY | None | An ignition occurred in 6A miner section caused by an abnormal rock intrusion. |
| 12/02/2018 | POWERED HAULAGE | DAYS AWAY FROM WORK ONLY | 81d lost | Employee was at the end of the track in 5A retrieving the winch rope hook from the scoop, when the hook struck them in the ribs causing a fracture. |
| 11/21/2018 | HOISTING | ACCIDENT ONLY | None | The elevator at Patterson Creek portal was out of service due to the governor cable malfunctioning. The cable and sensor were cleaned and the elevator returned to normal service. |
| 11/20/2018 | SLIP OR FALL OF PERSON | NO DYS AWY FRM WRK,NO RSTR ACT | None | Employee was hooking up can setter and slipped and hit finger causing injury. Original accident happened on 11/14/18 and continued to work. EE did not seek medical treatment until 11/20 and then was... |
| 11/15/2018 | HANDLING OF MATERIALS | NO DYS AWY FRM WRK,NO RSTR ACT | None | Employee was loading dust line onto a gen and was struck in the head by a coupler. |
| 11/13/2018 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | An unintentional roof fall occurred in 3 East Mains 23 Wall #1 Entry Intersection. There were no injuries as a result of this incident. Conditions contributing to the roof fall are adverse roof condit... |
| 10/09/2018 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | An unintentional roof fall occurred in 3 East Mains 2 Wall #1 Entry Intersection. There were no injuries as a result of this incident. Conditions contributing to the roof fall are humidity in the area... |
| 09/22/2018 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | Unintentional roof falls occurred in 3 East Mains 10 Wall #4 Entry Intersection and 11 Wall 3-4 Crosscut. There were no injuries as a result of this incident. Conditions contributing to the roof fall... |
| 09/15/2018 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | Unintentional roof falls occurred in 3 East Mains 5 Wall 4-5 Crosscut; 3 Wall 3-5 Crosscuts; 1-2 Wall #5 Entry. There were no injuries as a result of this incident. Conditions contributing to the roof... |
| 08/29/2018 | FALL OF ROOF OR BACK | DAYS AWAY FROM WORK ONLY | 16d lost | Employee was roof bolting on the return side of the miner in the 5A section. While drilling a bolt hole a rock approx. 4' x 3' x 1"" came out of the roof area and struck EE's right lower leg causing a... |
| 08/27/2018 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | An unintentional roof fall occurred in 3 North Mains in #10 entry from 9 wall to 11 wall. The fall measured approximately 12'-15' high by 16' wide and 450' long. There were no injuries as a result of... |
| 07/25/2018 | HOISTING | ACCIDENT ONLY | None | The BMX slope hoist was out of service due to a kink in the hoist rope. The rope was re-terminated and the hoist returned to service. |
| 07/20/2018 | HANDTOOLS (NONPOWERED) | DAYS AWAY FROM WORK ONLY | 36d lost | Employee was putting links together on the conveyor chain on 5A miner. When EE swung EE's hammer, EE missed the link and hit EE's right thumb between the boom and the hammer. Employee worked up to 7/2... |
| 07/10/2018 | HOISTING | ACCIDENT ONLY | None | The elevator at Patterson Creek portal was out of service due to a malfunction with the slow down switches. The elevator was reset and returned to normal service. |