| 11/17/2012 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | There was a roof fall in the #2 entry 60' inby SS #3326 and then run across intersection to # 1 entry #3 stayed up #4, #5 fall area was bolted with 6' super twist and 12' TCB bolts. The fall was in #2... |
| 09/10/2012 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | The roof fall occurred in the 1st left butt section at 8:30am 25' inby station spad #3093. The fall was approx 23 wide from 4-5 acres intersection and 8' to 10' deep and of unknown height the area was... |
| 08/31/2012 | HANDLING OF MATERIALS | DAYS AWAY FROM WORK ONLY | 34d lost | Pulling pin to release dust car pulled pin car moved and pinched finger. |
| 08/16/2012 | MACHINERY | DAYS AWAY FROM WORK ONLY | 69d lost | Bolting abnormal roof installing a cable bolt. Was pushing steels in roof with machine and caught finger between roof and bolter head |
| 06/20/2012 | HANDLING OF MATERIALS | DYS AWY FRM WRK & RESTRCTD ACT | 102d lost, 22d restricted | Hand was resting on cable and it pulled tight springing arm upward resulting in a torn bicep muscle. At this time the injured person reported this accident but did not receive med attention. Employee... |
| 06/25/2011 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | Roof fall was in the 3rd Northwest Butt Room section in #23 room 45' inby spad # 2082 The fall was approx. 55' L. in #23 room and fell through X.C. 30'L. towards #24 room 18' W. unknown H. Area was bo... |
| 10/13/2010 | MACHINERY | DYS AWY FRM WRK & RESTRCTD ACT | 12d lost, 18d restricted | EMPLOYEE HAD PULLED UP TO MINER WITH HIS SHUTTLE CAR AND HAD JUST SWITCHED SEATS WHEN THE MINER OPERATOR SWUNG THE TAIL OF THE MINER AND BUMPED THE CAR INTO THE RIB. THE CAR OPERATOR'S THUMB WAS BETWE... |
| 08/03/2010 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | Discovered roof fall on weekly Return Run in 1st NWest Mains Section 1 xcut inby station #1380 in #2 entry. Area was bolted w/6' supertwist fully grouted 12' cable bolts, 2 every 8' & T2 channels. Fal... |
| 07/24/2010 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | Examiner was starting pre-shift, was checking fan & saw no water coming out of mine. He went to investigate & found roof fal in #2 entry of 1st NW Mains, 120' inby station #116. This is about 1500' in... |
| 06/16/2010 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | An unintentional roof fall occurred in 1st Northwest main at 6:25a.m. The fall was in the #3 entry outby the face of the # 3 entry and 50'inby S 1379. Fall was 50' to 60' long and 17'-19' wide. Area w... |
| 06/08/2010 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | Discovered fall in the #4 entry of 1st north west mains section 25' inby survey station # 1371. The fall was 40' long by 30' wide by 12' to 13' high. Area was supported with 6' supertwist bolts, T-2 c... |
| 05/17/2010 | FALL OF ROOF OR BACK | DYS AWY FRM WRK & RESTRCTD ACT | 28d lost, 14d restricted | While installing roof bolts, the employee heard the roof crack, he tried to retreat but was struck by a rock that fell from between the bolts and the rib. |
| 10/15/2009 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | Crew heard roof fall in adjacent room. Section foreman went to investigate and found fall in #2 room through #3 room. Fall was 18' high x 45' long x 5' high. Area was bolted with 4' resin bolts. Rock... |
| 07/29/2009 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | Preshift examiner discovered a roof fall in 2nd SW Butt #1 Entry (room neck) Inby spad #547. The fall was in the intersection extending into #1 entry and x-cut 2-1 in both directions. Fall was approx.... |
| 07/29/2009 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | Discovered a roof fall in 1 nw butt when doing weekly air course run. Fall was in #2 entry 2 X-cuts inby spad #173, extending about halfway into the intersection. Fall was about 40' long by 18' wide a... |
| 07/01/2009 | HANDLING OF MATERIALS | DYS AWY FRM WRK & RESTRCTD ACT | 30d lost, 15d restricted | Employee was turning in seat of scoop to exit when foot got caught twisting knee. |
| 02/04/2009 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | Discovered roof fall on weekly run in the 1st sw butt at spad #10 in #3 entry fall was from #3 entry to #2 entry through vent 3 to 2 fall was 19' wide 75' long and 6' to 8' high entry had be bolted wi... |
| 01/23/2009 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | Discovered a roof fall in the 1st NW Parallel Butt 55' inby station #112. The fall was from #4 intersection to #5 intersection about 70' long, 8'-16' high. Area was bolted with 6' fully grouted & 4' f... |
| 11/26/2008 | HANDLING OF MATERIALS | NO DYS AWY FRM WRK,NO RSTR ACT | None | While mudding wall with b-bond, the mud fell inside his gloves. |