Independent Salt Company — Accidents
Total: 130 accidents | Fatalities: 0
| Date | Classification | Injury | Days Lost | Narrative |
|---|---|---|---|---|
| 03/31/2011 | HOISTING | ACCIDENT ONLY | None | The main hoist went out of service at 4:15pm. Upon investigation a hydraulic line fitting blow out was discovered. At 4:40pm the men underground were evacuated to the surface of our #3 shaft. At 4:... |
| 01/18/2011 | HOISTING | ACCIDENT ONLY | None | The #1 hoist went out of service due to rope stretch. It was observed that the skip was unable to to reach elevations high enough to dump. The rope was taken up to to correct the problem. Hoist was pl... |
| 09/28/2010 | POWERED HAULAGE | DAYS AWAY FROM WORK ONLY | 29d lost | Employee was driving a golf cart from the working face of the mine to the lunch room when making a turn the cart rolled and employee fell out and impacted shoulder to the rough salt floor. Employee su... |
| 06/21/2010 | HANDTOOLS (NONPOWERED) | DAYS AWAY FROM WORK ONLY | 5d lost | Employee was helping to put a shaft timber in place. When he pulled down on a pry bar he felt a pain in his mid-section. He finished his shift that day, but upon returning to work the next day he wa... |
| 06/01/2010 | HOISTING | ACCIDENT ONLY | None | Main production hoist would not operate due to a hydraulic fault. Fault was determined to be the result of the hydraulic contact switch not working properly. |
| 05/26/2010 | HOISTING | ACCIDENT ONLY | None | Due to a problem incurred somewhere along the transmission lines of the company that provides electricity to the mine, electricity to the mine was lost. This resulted in the main hoist being inoperab... |
| 05/14/2010 | HOISTING | ACCIDENT ONLY | None | Hoist operator lost power to hydraulic controls due to a burnt up hydraulic electrical control switch. The control switch was replaced and the hoist was operational at 11:00 pm. |
| 05/12/2010 | HOISTING | ACCIDENT ONLY | None | During the quarterly inspection, MSHA inspectors requested to exit the mine through the escape shaft. When decending the skip to the bottom, the skip would get stuck prior to reaching the bottom. Up... |
| 04/05/2010 | HANDLING OF MATERIALS | DAYS AWAY FROM WORK ONLY | 4d lost | Employee was experiencing discomfort in his right forearm and elbow. Medical diagnosis is belief that employee has tendinitis secondary to repetitive movements at work filing sacks of salt. |
| 01/02/2010 | HOISTING | ACCIDENT ONLY | None | Main hoist would not start up. Weather overnight was extremely cold, and it is believed that extremely low temperatures was causing too much drag on the M.G. Set during startup. Hoist was placed in... |
| 12/07/2009 | HOISTING | ACCIDENT ONLY | None | Main hoist would not start. Trouble shooting & inspection was done on the hoist. During a start up, it was noticed that M.G. set was making a noise. A shaft bearing on the DC side of the M.G. set w... |
| 12/04/2009 | HOISTING | ACCIDENT ONLY | None | The main hoist would not start. After checking system over, the operating parameters were changed allowing the M.G. Set to start. However, the voltage level was twice the norm. The Static Field Com... |
| 08/07/2009 | DISORDERS (REPEATED TRAUMA) | OCCUPATNAL ILLNESS NOT DEG 1-6 | 1d lost | Employee was experiencing pain in his left shoulder. Medical professional feels that it is likely tendonitis brought on by the repetitive motion involved with the employee's work. |
| 07/30/2009 | MACHINERY | NO DYS AWY FRM WRK,NO RSTR ACT | None | Pinched fingers between guard on scissor lift. |
| 05/18/2009 | POWERED HAULAGE | DAYS AWAY FROM WORK ONLY | 112d lost | Employee was driving a golf cart along the underground conveyor beltline and his leg struck an emergency stop box that protrudes out from the beltline. Employee suffered a broken left leg. |
| 05/08/2009 | HOISTING | ACCIDENT ONLY | None | Failure of drive communication board in hoist system resulted in shutting down the hoist to replace the board. It is believed that a thunderstorm from the prior day may have contributed to the failur... |
| 04/06/2009 | HANDLING OF MATERIALS | DAYS AWAY FROM WORK ONLY | 82d lost | On April 6, 2009, employee reported that he was going to see the doctor regarding pain and inflamation in his left arm (elbow area). Employee was given injections to help alleviate the problem. From... |
| 10/10/2008 | HOISTING | ACCIDENT ONLY | None | Main hoist system experienced a field loss when running the daily brake test. After locating the problem, fuses were replaced and the problem was corrected. No men were underground at the time of th... |
| 09/22/2008 | HOISTING | ACCIDENT ONLY | None | An apparent power spike went through power lines of Western Electric over the weekend. When our hoist operator attempted start up on Monday, hoist did not operate. This was prior to shift starting. Th... |
| 08/16/2008 | HOISTING | ACCIDENT ONLY | None | A section of frame for a new wheeloader was being lowered down the main production shaft into the mine. During the lowering, the frame began to rotate and got caught. The main production shaft was o... |
| 06/16/2008 | POWERED HAULAGE | DAYS AWAY FROM WORK ONLY | 4d lost | Employee was in a manbasket on a forklift painting a warehouse loading dock canopy. When the forklift operator moved the forklift, he misjudged the distance between the manbasket and and a steel gird... |
| 03/17/2008 | HOISTING | ACCIDENT ONLY | None | Dus to intermittent loss of power to the synchronous motor protector, the hoist was taken out of service @ 445pm. After resetting the field with amps, the hoist was placed back in service @535pm. The... |
| 03/07/2008 | SLIP OR FALL OF PERSON | ALL OTHER CASES (INCL 1ST AID) | None | The driver of a customers truck fell as he getting out of his truck.In trying to catch/brace himself the man landed on his right hand.Due to swelling and pain, a mine EE applied a samsplint,ice pack a... |
| 12/17/2007 | HOISTING | ACCIDENT ONLY | None | At 4:08 PM an interruption in the electrical supplyoccurred, which we believe was a surge in power and to which the power company said likely did happen. Result was damage to a circuit board panel in... |
| 12/11/2007 | HOISTING | ACCIDENT ONLY | None | Downed power lines, etc. brought about by a heavy ice storm resulted in electricity going out at approximately 11:30 AM, December 11, 2007. The power company finally restored power to the mine locati... |
| 11/26/2007 | HOISTING | ACCIDENT ONLY | None | At 10:40 AM the hoist stopped responding and all men were immediately brought up out of the mine. Technicians were called out, and problem was found to be a bad wire connection in an electrical panel... |
| 11/26/2007 | HOISTING | ACCIDENT ONLY | None | After initial inspection and tests were run, hoist did not respond properly. Computer was reading a PLC communication fault. Technicians were called out, and at 9:45 AM the hoist responded. Followi... |
| 01/15/2007 | HOISTING | ACCIDENT ONLY | None | Motor generator set that generates direct current power for the production/man hoist would not synchronize. Problem appeared to be temperature related. Notification was made to toll-free #, and no e... |
| 08/09/2006 | HOISTING | ACCIDENT ONLY | None | A hydraulic fitting on the hoist braking system cracked and leaked hydraulic oil. The hoist was shut down to install replacement fitting. No one was underground whle the hoist was down. Incident re... |
| 08/08/2006 | HANDLING OF MATERIALS | NO DYS AWY FRM WRK,NO RSTR ACT | None | Hurt his right elbow when a guard he was fitting on an overhead conveyor slipped. |
| 07/05/2006 | MACHINERY | NO DYS AWY FRM WRK,NO RSTR ACT | None | Employee was grinding on a piece of metal with a hand grinder when a fleck of metal got past his shield and safety glasses and entered his left eye. Employee went to ophthalmologist to have the forei... |
| 06/02/2006 | HANDLING OF MATERIALS | NO DYS AWY FRM WRK,NO RSTR ACT | None | Employee was working in the shaft when his left hand struck a nail, which pierced the skin and resulted in some bleeding. Overnight the employee had swelling in the area where the nail pierced his ha... |
| 05/17/2006 | MACHINERY | NO DYS AWY FRM WRK,NO RSTR ACT | None | Employee was grinding a piece of iron with a hand grinder when a fleck of metal got past his shield and safety glasses and entered his left eye. Employee went to the optometrist to have the foreign b... |
| 01/23/2006 | HANDTOOLS (NONPOWERED) | NO DYS AWY FRM WRK,NO RSTR ACT | None | Employee was tapping out a 3/8"" nut for a guard when the tap slipped out of the employee's hand. The employee reached suddenly to catch the tap and felt a sharp pain in his lower back. |
| 12/08/2005 | HOISTING | ACCIDENT ONLY | None | Motor generator set that generates direct current power for the production/man hoist would not synchronize. Problem appears to be temperature related. Item was reported to Dustin Creley who was on-s... |
| 10/22/2005 | HANDLING OF MATERIALS | NO DYS AWY FRM WRK,NO RSTR ACT | None | Employee struck his hard hat/head against a wire insulator attached to the mine roof as he was carrying parts across a catwalk on the surge bin at the shaft bottom. Employee injured his neck - cervic... |
| 09/26/2005 | HOISTING | ACCIDENT ONLY | None | 500KW generator portion of MG set was showing temperature readings in excess of nominal. Investigation revealed some broken springs used to apply proper brush friction. All brushes and some springs... |
| 09/01/2005 | SLIP OR FALL OF PERSON | NO DYS AWY FRM WRK,NO RSTR ACT | None | Employee was pulling cable down a belt line when he slipped and fell. Upon falling, the employee's right leg landed on a chunk of salt just below the knee. The employee sustained a deep bruise to hi... |
| 07/26/2005 | HOISTING | ACCIDENT ONLY | None | Prior to start of daily operations, hydraulic pump to the hoist brake system was showing inadequate pressure. After adjustments, the hoist was put back into service at 9:00 AM. Later in the morning... |
| 06/17/2005 | MACHINERY | NO DYS AWY FRM WRK,NO RSTR ACT | None | Employee was filling 50lb bags of salt. While holding a bag up to the spout and filling, he lost hold of the bag. This resulted in his arm rising quickly and striking his left forearm against the ch... |
| 05/19/2005 | OTHER | ALL OTHER CASES (INCL 1ST AID) | None | Individual was participating in a mine rescue team competition/training at Hutchinson, KS. Due to exteneded exposure to midday sun during the competition/training, the individual sustained a blisteri... |
| 02/22/2005 | OTHER | INJURIES DUE TO NATURAL CAUSES | 39d lost | Employee started experiencing extreme shortness of breathe and a burning sensation in his chest. He immediately left work to go to the hospital. The employee was starting to have a heart attack and... |
| 01/08/2005 | HOISTING | ACCIDENT ONLY | None | At 1:55 pm the electric company experienced some type of problem which resulted in the loss of transmission of electricity to the area that included Independent Salt Comapny. Three employees who were... |
| 09/27/2004 | HOISTING | ACCIDENT ONLY | None | The production/man hoist is computer controlled. The computer was not able to display information on the monitor to permit the hoist operator to complete his safety checks nor to re-set any faults th... |
| 07/07/2004 | HOISTING | ACCIDENT ONLY | None | Blown fuse on circuit board that controls high speed breaker. Circuit board was faulted due to a faulty coil. |
| 06/18/2004 | HOISTING | ACCIDENT ONLY | None | HOIST WAS BEING OPERATED WITH 3 MEN DOING MAINTENANCE WITHIN THE SHAFT. HEAVY RAIN WAS FALLING. RUNOFF EVENTUALLY OVERCAME THE DITCHING AROUND BUILDINGS. WATER FLOODED INTO A STORAGE BLDG., INTO AN OL... |
| 06/15/2004 | HOISTING | ACCIDENT ONLY | None | AT APPROX. 1:10AM, A CITY WIDE POWER OUTAGE OCCURRED WHICH RENDERED THE HOIST INOP, DUE TO A BLOWN FUSE AT THE SUB-STATION. AT THAT TIME, 3 MEN WERE WORKING IN THE PRODUCTION SHAFT. UPON ARRIVING AT 1... |
| 06/08/2004 | HOISTING | ACCIDENT ONLY | None | During a shift change, the hoist operator noticed that the hydraulic oil had a milky white appearance to it. The hoist was shut down until the hydaulic oil in the hoist brake system was drained, flus... |
| 05/30/2004 | HOISTING | ACCIDENT ONLY | None | During the weekend of 5/29-5/30 the hoist basement took on water during hard rainfalls during short periods of time. The water submerged brake pumps and the drum gear pump. The basement was pumped d... |
| 03/22/2004 | MACHINERY | NO DYS AWY FRM WRK,NO RSTR ACT | None | The employee's left eye began bothering him after work the evening of 03/22/04. During his shift that day he did numberous jobs which included grinding, welding and using a torch. Apparently some ti... |