Island Mine #1 — Accidents
Total: 90 accidents | Fatalities: 0
| Date | Classification | Injury | Days Lost | Narrative |
|---|---|---|---|---|
| 05/24/2001 | DISORDERS (REPEATED TRAUMA) | OCCUPATNAL ILLNESS NOT DEG 1-6 | 1d lost | SWELLING AND BURSITIS DEVELOPED IN RIGHT KNEE OFEMPLOYEE DUE TO REPETITIVE BENDING AND KNEELING. |
| 05/23/2001 | OTHER | NO DYS AWY FRM WRK,NO RSTR ACT | None | EMPLOYEE WAS GETTING OUT OF SCOOP TO REMOVE A PIECE OF BELT FROM THE BUCKET. THE TOP WAS LOW WHERE HE WAS GETTING OUT OF THE SCOOP AND HE TWISTED AND FELT A PAIN IN HIS LOWER BACK. |
| 05/04/2001 | HANDLING OF MATERIALS | DAYS AWAY FROM WORK ONLY | 135d lost | EE WAS IN THE PROCESS OF MOVING THE CONTINUOUS MINER ACROSS THE SECTION. HE HAD TO PULL THE MINER CABLE AND HOSE TO PUT ON THE HORN OF THE MINER SO HE DRAGGED IT TO THE MINER AND THEN FELT A PAIN IN H... |
| 03/21/2001 | HANDLING OF MATERIALS | NO DYS AWY FRM WRK,NO RSTR ACT | None | EMPLOYEE SET A FULL BOX OF GLUE ON HIS TRAY ON THE ROOF BOLTER, HE WENT TO PICK THE BOX UP AND MOVE IT OVER BEHIND THE TRAY AND AT THIS TIME FELT A PAIN IN HIS LOWER BACK. |
| 03/01/2001 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | A CONTINUATION OF AN EXISTING FALL OCCURRED IN THE 6TH SOUTHWEST PANEL IN THE #3 ENTRY FROM XCUT 12 TO 17. IT WAS APPROX. 276' LONG X 18' WIDE X 6-8' HIGH AND WAS SUPPORTED WITH 5' FULLY GROUT ED BOLT... |
| 02/22/2001 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | A FALL OF ROOF OCCURED IN THE 6TH SOUTHWEST PANEL IN THE #3 ENTRY AT X-CUT 19. THIS WAS A CONTINUATION TO AN EXISTING FALL THAT FELL THE DAY BEFORE. THE AREA WAS SUPPORTED WITH 5' FULLY GROUTE D BOLTS... |
| 02/21/2001 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | A FALL OF ROOF OCCURRED IN THE 6TH SOUTH WEST PANEL IN THE #3 ENTRY AND WAS APPROX 900 FT FROM THE SECTION DUMPING POINT. THE FALL WAS APPROX 85' X 18' X 6'-8'. THE AREA WAS SUPPORTED WITH 5' FULLY GR... |
| 02/01/2001 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | A FALL OF ROOF OCCURRED IN THE WEST MAIN ENTRIES IN THE #2 ENTRY AT XCUT #6 APPROX. 10,900' OUTBY THE SECTION. THE FALL WAS APPROX 26' LONG X 20' WIDE X 6 1/2' HIGH. THE AREA WAS SUPPORTED WIT H 6' FU... |
| 12/19/2000 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | A FALL OF ROOF OCCURRED IN THE WEST MAIN ENTRIES AT XCUT 24 IN THE #5 ENTRY APPROX. 9300; FROM THE UNIT. THE FALL WAS APPROX 25' X 19' X 8' AND WAS SUPPORTED WITH 6' FULLY GROUTED BOLTS AND TR USSBOLT... |
| 10/17/2000 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | A FAL OF ROOF OCCVURRED IN THE 1ST NE SUBMAINS IN THE #7 ENTRY IN BETWEEN #6 & #7 XCUT. THE FALL WAS APPROX 12, 400' OUTBY THE UNIT AND WAS APPROX 30' X 20' X 7'. THE AREA WAS SUPPORTED WITH 6 ' TENSI... |
| 10/16/2000 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | A FALL OF ROOF OCCURRED IN THE #7 ENTRY OF THE WEST MAINS INBY XCUT 27 TO XCUT 29 APPROX. 8200' FROM THE UNIT. THE FALL WAS APPROX 90' X 18' X 7-8'. THE AREA WAS SUPPORTED WITH 6' FULLY GROUTE D BOLTS... |
| 10/16/2000 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | A FALL OF ROOF OCCURED IN THE WEST MAIN ENTRIES X-CUT 38 IN THE #3 ENTRY. OUTBY THE UNIT & THE AREA WAS DEVELOPED 9/21/98. THE AREA WAS SUPPORTED WITH 6FT FULLY GROUTED BOLTS |
| 10/10/2000 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | A FALL OF ROOF OCCURED IN THE WEST MAIN ENTRIES IN THE #7 ENTRY AT X CUT #45 APPROX. 7250 FT OUTBY #1 UNIT. THE FALL WAS APPROX. 50'X18'X7' THE AREA WAS SUPPORTED WITH 6 FT FULLY GROUTED BOLTS AND SUP... |
| 10/10/2000 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | A FALL OF ROOF OCCURED IN THE WEST MAIN ENTRIES IN THE #8 ENTRY AT X CUT #44 APPROX. 7275 FT OUTBY #1 UNIT. THE FALL WAS APPROX. 80'X18'X7' THE AREA WAS SUPPORTED WITH 6FT FULLY GROUTED BOLTS AND SUPP... |
| 09/27/2000 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | A FALL OF ROOF OCCURRED IN THE WEST MAIN ENTRIESIN THE #4 ENTRY AT X-CUT #8 APPROX 9000 FT OUT BY #1 UNIT. THE FALL WAS APPROX 20' BY 14' BY 6' THE ARM WAS SUPPORTED WITH 6 FT FULLY GROUTED BO LTS AND... |
| 09/18/2000 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | A FALL OF ROOF OCCURED IN THE 1ST SOUTHWEST SUBMAINS IN THE #3 ENTRY AT X-CUT #10 APPROX 3400 FT FROM #1 UNIT. THE FALL WAS APPROX 25'X20'X6 1/2"". THE AREA WAS SUPPORTED WITH 6' FULLY GROUTE D ROOF B... |
| 09/16/2000 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | A FALL OF ROOF OCCURRED IN THE #5 ENTRY OF THE 3RD SOUTHWEST PAHEL APPROX. 50' INBY THE LAST OPEN XCUT AND 200' INBY THE UNIT TAILPIECE. THE AREA WAS BOLTED WITH 5' FULLY GROUTED ROOF BOLTS AN D WAS A... |
| 09/15/2000 | MACHINERY | DAYS AWAY FROM WORK ONLY | 5d lost | EE WAS REPINNING THE INTERSECTION OF #2 ENTRY. AROCK FELL FROM IN BETWEEN BOLTS AND HIT HIS LEG AND PINNER STEEL THAT WERE LAYED ACROSS THE BOOM OF THE BOLTER,IN TURN THE STEELS TRUCK HIM IN THE GROIN... |
| 09/01/2000 | HANDLING OF MATERIALS | DAYS AWAY FROM WORK ONLY | 123d lost | EE AND ANOTHER MINER WERE MOVING A LARGE OXYGEN BOTTLE INTO THE PIT SHOP WHEN EE STEPPED ON A ROCK AND THEN FELT A PAIN IN HIS LOWER BACK. |
| 08/27/2000 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | A FALL OF ROOF OCCURRED IN THE WEST MAIN ENTRIES INBETWEEN X-CUT 38 AND 39 IN THE #5 ENTRY APPROX 7600 FT OUTBY #1 UNIT. THE FALL WAS APPROX 50'LX 18'W X 6 1/2'H. THE AREA WAS SUPPORTED WITH 6' FULLY... |
| 08/16/2000 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | A ROOF FALL OCCURRED IN THE WEST MAIN ENTRIES ATX-CUT 49 IN THE #8 ENTRY APPROXIMATELY 6220 FEETOUTBY #1 UNIT. THE FALL MEASURED 28' X 19' X 7'.THE AREA WAS SUPPORTED WITH 6' FULLY GROUTED BOL TS AND... |
| 08/15/2000 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | ROOF FALL OCCURRED IN WEST MAIN ENTRIES AT X-CUT23 IN THE #7 ENTRY APPROXIMATELY 8,080' OUTBY #1UNIT. THE FALL MEASURED 20' X 20' X 6' & WAS SUPPORTED WITH 6' FULLY GROUTED BOLTS & 2 PROPSETTE RS. THE... |
| 08/04/2000 | STRIKING OR BUMPING | NO DYS AWY FRM WRK,NO RSTR ACT | None | EMPLOYEE WAS IN THE PROCESS OF SPOTTING A ROOF BOLT WITH A FLETCHER BOLTER WHEN HE TURNED TO SEE THE LOCATION OF THE BOLT AND POSITION THE BOLTER. HE THEN PROCEEDED TO THE FRONT OF THE BOLTER AND RAN... |
| 08/01/2000 | STRIKING OR BUMPING | NO DYS AWY FRM WRK,NO RSTR ACT | None | EE WAS WALKING ON THE SECTION TOWARD THE FACE AREA WHEN HE RAN INTO A LOW HANGING BENT ROOF BOLT. WHICH CAUSED A LACERATION ON HIS NECK THAT REQUIRED STITCHES. |
| 07/28/2000 | HANDLING OF MATERIALS | DAYS AWAY FROM WORK ONLY | 9d lost | EE WAS PUSHING A HEINTZMAN ROOF SUPPORT JACK UNDER THE NORTH WEST A BELT LINE WHEN HE FELT A PAIN IN HIS LOWER BACK. |
| 07/24/2000 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | A FALL OF ROOF OCCURRED IN THE WEST MAIN ENTRIES IN THE #3 ENTRY AT X-CUT 23 6933 FT. OUTBY #1 UNIT. THE FALL WAS APPROX. 20' X 18' X 7'. THE AREA WAS SUPPORTED WITH 6' FULLY GROUTED BOLTS A ND WAS MI... |
| 07/14/2000 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | A FALL OF ROOF OCCURRED IN THE NORTHWEST MAINS IN THE #4 ENTRY FROM XCUT 68 1/2 TO XCUT 70. THE FALL WAS APPROX 80' LONG X 19' WIDE X 7-10' HIGH. THE AREA WAS PREVIOUSLY MINED AROUND 2-28-95 A ND WAS... |
| 07/13/2000 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | A FALL OF ROOF OCCURRED IN THE NORTH WEST MAINS IN THE #5 ENTRY AT XCUT 79. THE FALL WAS APPROX 60' LONG X 18' WIDE X 7' HIGH. THE AREA WAS MINED APPROX 3-31-95 AND WAS SUPPORTED WITH 7' DOUBL E LOCK... |
| 07/03/2000 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | A FALL OF ROOF OCCURRED IN THE 1ST S.W. SUBMAINS IN THE #6 ENTRY AT X-CUT 32 EXTENDING TOWARD X-CUT 31. THE FALL WAS APPROXIMATELY 1900' OUTBY #1 UNIT; THE SIZE WAS APPROX. 15' L X 18' W X 6 1/2' H. A... |
| 05/22/2000 | HANDLING OF MATERIALS | DAYS AWAY FROM WORK ONLY | 1d lost | EE ATTEMPTED TO INSTALL A BENT ROOF BOLT IN THE ROOF AND AS HE STRAIGHTENED THE BOLT IT SPUN AROUND AND HE FELT A PAIN IN HIS ELBOW. |
| 05/12/2000 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | A FALL OF ROOF OCCURRED IN THE NORTH WEST MAINS INTAKE X-CUT 57 IN THE #7 ENTRY. THE FALL WAS APPROX 19'L, 24'W, 6-6.5'H. THE AREA WAS MINED APPROX 1/5/95 AND SUPPORTED WITH 6' BOLTS. |
| 05/02/2000 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | A FALL OF ROOF OCCURRED IN THE 5TH NE PANEL ON THE #2 UNIT IN THE #2 ENTRY - 3 X-CUTS INBY THE SECTION TAILPIECE. THE FALL WAS APPROX 19'W, 5.5'H, 40'L. DUE TO AN UNDETECTED SLIP. THE AREA WAS BOLTED... |
| 05/01/2000 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | A FALL OF ROOF OCCURRED IN THE 5TH NE PANEL IN THE #1 ENTRY X-CUT 46 AND 46 2 X-CUTS INBY THE TAILPIECE. THE FALL WAS DUE TO AN UNDETECTED SLIP. THE FALL WAS APPROX 75'L, 20'W, 5'HIGH. 5' FULL Y GROUT... |
| 04/25/2000 | HANDLING OF MATERIALS | NO DYS AWY FRM WRK,NO RSTR ACT | None | EE WAS SCATTERING TIMBERS FOR BELT LAY, AS HE REACHED AND PICKED UP A TIMBER HE FELT A PAIN IN HIS LOWER BACK. |
| 04/06/2000 | MACHINERY | NO DYS AWY FRM WRK,NO RSTR ACT | None | EE WAS INSTALLING A ROOF BOLT IN THE ROOF HE USED BOTH ARMS TO STRAIGHTEN THE BOLT TO PUT INTO THE ROOF AT THIS TIME THE BOLT SPUN AROUND AND HE SPUN AROUND AS WELL. HE STOPPED WHEN HE FELL AG AINST T... |
| 03/10/2000 | HANDTOOLS (NONPOWERED) | NO DYS AWY FRM WRK,NO RSTR ACT | None | EMPLOYEE WAS IN THE PROCESS OF OPENING AN OLD SPLICE INT HE MINER CABLE AND AS HE WAS CUTTING THE TAPE OFF WITH A BELT KNIFE HE CUT HIS LEFT HAND. |
| 02/02/2000 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | A FALL OF ROOF OCCURRED IN THE 1ST SOUTH WEST SUBMAINS IN THE #4 ENTRY AT X-CUT 37 APPROX 2500 FT. OUTBY THE #1 UNIT. THE AREA WAS SUPPORTED WI TH 6 FT FULLY GROUTED BOLTS AND TRUSS BOLTS. THE APPAREN... |
| 01/22/2000 | HANDLING OF MATERIALS | NO DYS AWY FRM WRK,NO RSTR ACT | None | EE WAS ROCK DUSTING IN A NEUTRAL ENTRY ON THE 1ST SW SUBMAINS AND AS HE WAS PULLING BACK THE DUST HOSE HE WALKED INTO A BENT ROOF BOLT RESULTING IN A LACERATION ON HIS LEFT EAR. |
| 01/19/2000 | HANDLING OF MATERIALS | NO DYS AWY FRM WRK,NO RSTR ACT | None | EE WAS PLACING HIS TOOLS IN HIS METAL TOOL BOX WHEN THE LID CAME DOWN AND STRUCK HIM IN THE LEFT EAR. THIS RESULTED IN A LACERATION TO THE LEFT EAR WHICH HE HAD TO HAVE 7 STITCHES. |
| 01/07/2000 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | A FALL OF ROOF OCCURRED IN THE NORTHWEST PARALLELS AT XCUT 13, SPAD 6+55, IN THE #2 ENTRY APPROX. 10,800' OUTBY #1 UNIT. THE FALL WAS APPROX 60' LONG X 18' WIDE X 6' HIGH. APPROX.D ATE OF DEVE LOPMENT... |