Leer South Mine — Accidents
Total: 586 accidents | Fatalities: 2
| Date | Classification | Injury | Days Lost | Narrative |
|---|---|---|---|---|
| 07/29/2005 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | An unintentional roof fall was discovered. Length 90'; width 20'; height 12' Roof suppport: 5' and 6' resin bolts with some 10 foot cable bolts Note: This abandonded section is to be rehabilitated fo... |
| 07/29/2005 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | An unintentional roof fall was discovered at C-main, entry 6, sta 10461. Length 80', width 20', height 8'. Roof support 5' resin. This abandoned section is to be rehabilitated for production. 8 falls... |
| 07/29/2005 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | An unintentional roof fall was discovered. Length 100', width 20', height 10', roof support 5' resin. This abandoned section is to be rehabilitated for production. 8 falls were discovered on 7-29-05,... |
| 07/29/2005 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | An unintentional roof fall was discovered on C-mains section, sta # 10416, #5 entry length 40', width 20', height 6'. Roof support 5' resin. This abandoned section is to be rehabilitated for productio... |
| 07/16/2005 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | An untentional roof fall occured on 6 #1 belt. The fall is in #5 and x-cut 4-5. Area was supported by 5' resin and truss bolts. Height -9'; Width - 18'; Length - 55'. Fall was timbered and dangered... |
| 06/30/2005 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | An unintentional roof fall was discovered on the B-2 East section belt. It occurred in a 4-way intersection with 60 degree crosscuts. The roof conditions were good in the area prior to the fall. Roo... |
| 06/08/2005 | HANDTOOLS (NONPOWERED) | DAYS AWAY FROM WORK ONLY | 3d lost | Injured was installing ""Keeper"" pins in the conveyor chain of CM using two hammers (striking them hammer to hammer) to bend the pin. A chip of metal flew from the masonry hammer striking and embedd... |
| 06/02/2005 | POWERED HAULAGE | DAYS AWAY FROM WORK ONLY | 18d lost | Two mantrips left the B-Mains section about 30seconds apart. The outby mantrip made an unplanned and uncommunicated stop after it went around a turn and through a switch and struck from behind by the... |
| 06/02/2005 | POWERED HAULAGE | DAYS AWAY FROM WORK ONLY | 264d lost | Two mantrips left the B-Mains section about 30seconds apart. The outby mantrip made an unplanned and uncommunicated stop after it went around a turn and through a switch and struck from behind by the... |
| 05/27/2005 | HANDLING OF MATERIALS | DAYS AWAY FROM WORK ONLY | 9d lost | Injured was shoveling on the belts and began experiencing severe lower back pain |
| 05/22/2005 | SLIP OR FALL OF PERSON | DAYS AWAY FROM WORK ONLY | 62d lost | Injured was standing on the belt rail of the lowlow when he lost his footing and fell, striking his shoulder on the low low rail. The injury was not reportable until he had surgery on the shoulder on... |
| 05/12/2005 | HANDLING OF MATERIALS | NO DYS AWY FRM WRK,NO RSTR ACT | None | Injured was assisting in unrolling 2"" plastic pipe for installation. The end of the pipe had been secured to the mine roof by tying it secure. The pipe came loose and struck the injured in mouth ca... |
| 05/01/2005 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | An unintentional roof fall has occured on the B2 East section, MMU 017-0 at Sta. 8+41. The area was supported with 5' resin bolts through out and 10' cable bolts in the intersection. H- 10' W- 20' L... |
| 04/28/2005 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | The weekly examiner discovered an unitentional roof fall in the #1 entry of C-Mains panel. The measurements are: H-6' W-24' L-18' Area was supported by 5' resin Area has been dangered off |
| 04/22/2005 | SLIP OR FALL OF PERSON | DAYS AWAY FROM WORK ONLY | 22d lost | Injured was carrying a belt return roller when he stepped on a loose rock causing him to slip, twisting his back |
| 04/22/2005 | FALL OF ROOF OR BACK | DAYS AWAY FROM WORK ONLY | 2d lost | Injured was struck on left foot by falling roof rock when he swung the head in to install the inside bolt on pattern. |
| 04/14/2005 | HANDLING OF MATERIALS | PERM TOT OR PERM PRTL DISABLTY | 2d lost | Injured was lifting on a roof bolter pump motor to turn it around in the scoop bucket when he felt a ""pop"" in his left abdomen area. |
| 04/05/2005 | FALL OF ROOF OR BACK | DAYS AWAY FROM WORK ONLY | 5d lost | Injured was struck by falling rock from between the bolts. Bolt spacing was with requirements of plan |
| 03/24/2005 | SLIP OR FALL OF PERSON | DAYS AWAY FROM WORK ONLY | 76d lost | Injured was moving CM cable out of roadway when he twisted his knee |
| 03/21/2005 | HANDLING OF MATERIALS | DAYS AWAY FROM WORK ONLY | 3d lost | Injured was straightening a roof bolt while installing it in the drill hole when he straiined his back |
| 03/17/2005 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | AN UNINTENTIONAL ROOF FALL OCCURRED ON B-SOUTH MAINS IN CROSSCUT 4-5 AT STA. 13278. PRIMARY ROOF SUPPORT - 5' RESIN. HEIGHT-6'. WIDTH-18'. LENGTH-25'. ADDITIONAL SUPPORT WAS ADDED IN ADJOINING ENTRIES... |
| 03/15/2005 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | (2ND OF 2 ROOF FALLS DISCOVERED ON 3/15/05.) An unintentional roof fall has occurred on B-Mains East in the #2 entry at station 13196. Height - 5', Width - 16',Length - 20'. Roof Support in area -... |
| 03/15/2005 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | (1ST OF 2 ROOF FALLS DISCOVERED ON 3/15/05.) An unintentional roof fall has occured on the old West Mains belt entry in the intersection at station #12968. Height - 6', Width - 20', Length - 18'.... |
| 03/01/2005 | FALL OF ROOF OR BACK | NO DYS AWY FRM WRK,NO RSTR ACT | None | Injured was struck by a rock which fell out around the drill steel. The rock, which had the steel through it, spun down the steel, broke in half causing a piece of the rock measuring 8"" by 8"" by 3"... |
| 02/22/2005 | HANDLING OF MATERIALS | DAYS AWAY FROM WORK ONLY | 38d lost | Injured had just finished assisting in the hanging of the cm and roof bolter cables when he began to experience pain in lower back and right leg. |
| 02/21/2005 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | An unintentional roof fall occurred at the south mains spur in a x cut developed 3/31/99, height-7' with-17'-length-25'-bolts 5' resin. |
| 02/21/2005 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | An unintentional roof fall occured. The area has clay a venvin it and same unconsolidated roof material. bolts installed were 5' resin 1 10' cable bolts height 7' width 18' length 25'. |
| 01/16/2005 | HANDLING OF MATERIALS | DAYS AWAY FROM WORK ONLY | 11d lost | Injured was rolling a rock out of the roadway when it slipped from his hands and fell back onto his leg |
| 01/15/2005 | SLIP OR FALL OF PERSON | DAYS AWAY FROM WORK ONLY | 31d lost | Injured was moving cables and curtain out of the travel path of the mobile bridge carrier when he stumbled over some rocks lying along the rib which had just been removed from the top of the continuou... |
| 01/03/2005 | FALL OF ROOF OR BACK | DAYS AWAY FROM WORK ONLY | 3d lost | Injured had positioned bolter boom to drill and had raised up the canopy to access the crill controls when thin head coal(1"") and some roof rock fell on the operator. The rock was 12"" by 12"" by 2""... |
| 12/29/2004 | HANDTOOLS (NONPOWERED) | NO DYS AWY FRM WRK,NO RSTR ACT | None | Individual was preparing a rusty metal surface for welding by using a chipping hammer when rust flew into his eye |
| 12/29/2004 | HANDLING OF MATERIALS | DAYS AWAY FROM WORK ONLY | 2d lost | Individual was on knees installing slides in the continuous haulage rapid haul (lowlow) when he twisted his body in an awkard position straining his back |
| 12/21/2004 | FALL OF ROOF OR BACK | NO DYS AWY FRM WRK,NO RSTR ACT | None | Injured was pulling a pin from the B-Mains East belt during a belt move when a rock measuring approx 3' to 0"" in width and 5' in length by 2"" thick fell. It knocked him to the side and a smaller ro... |
| 12/07/2004 | ENTRAPMENT | ACCIDENT ONLY | None | As the dayshift crew were beginning to descend down the shaft, an electrical contactor malfunctioned causing the elevator to stop one foot below the top landing platform. After being stuck for 36 min... |
| 11/29/2004 | OTHER | DAYS AWAY FROM WORK ONLY | 9d lost | Individual had knelt down to work on a pump power plug at the 6#1 belt load center. As he twisted his body to stand up, he felt pain in his lower back and was unable to straighten up. He walked a sho... |
| 11/20/2004 | MACHINERY | DAYS AWAY FROM WORK ONLY | 11d lost | Injured had scaled roof down and installed first row. They moved bolter to install the 2nd row of bolts. As he positioned his body to insert the resin and bolt, he placed his rt. hand on the bolter b... |
| 11/02/2004 | MACHINERY | NO DYS AWY FRM WRK,NO RSTR ACT | None | A loose rock had set down on the roof bolter canopy. As the injured lowered the canopy to swing the boom of the bolter he had placed his hand on the head of the boom, the rock feel off the canopy str... |
| 11/02/2004 | SLIP OR FALL OF PERSON | DAYS AWAY FROM WORK ONLY | 44d lost | Injured was dismounting a rail mantrip when he felt his knee fail. There were no tripping hazards or loose material involved in the incident, only body motion and possibly poor body positioning. |
| 11/01/2004 | HANDLING OF MATERIALS | DAYS AWAY FROM WORK ONLY | 106d lost | Injured strained muscles in back while pushing bolt up through resin into bolt hole |
| 10/28/2004 | MACHINERY | DAYS AWAY FROM WORK ONLY | 38d lost | Injured was installing a 5' resin grouted rod in the mine roof. As he pushed it up with the bolter head it bent very quickly causing it to be fouled in the bolter head and the bolt hole. He attempte... |
| 10/19/2004 | MACHINERY | DAYS AWAY FROM WORK ONLY | 143d lost | Injured was struck on leg by rock measuring 30"" wide x 48"" long x 2"" thick while operating the roof bolter |
| 10/11/2004 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | An unintentional roof fall occured on the West Mains track entry on the left side of the entry. The area is supported by 5' fully grouted resin bolts. Height - 4' Width - 8' Length - 50' The area may... |
| 10/08/2004 | HANDTOOLS (NONPOWERED) | DAYS AWAY FROM WORK ONLY | 78d lost | Injured was trouble shooting a cm with a field rep. As they were reattaching the rubrail on the side of the cm, using a slate bar for leverage, he felt pain in his lower back and hip. |
| 09/18/2004 | HANDTOOLS (NONPOWERED) | NO DYS AWY FRM WRK,NO RSTR ACT | None | Injured was assisting in installing a new splice on conhveyor belt when he reach in to move the multi-driver over in the driver blocks. As he grabbed the driver to move it, he was struck on the hand... |
| 09/16/2004 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | An unintenetional roof fall occurred on the 6#1 belt. The mine roof was busted up from earlier cutters(4 yrs ago) and cribs were set in the intersection. The roof ""potted out"" over the belt and on... |
| 09/14/2004 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | An unintentional roof fall was discovered in the intake along the 6#1 track. It measures 7' high, 20' wide, 22' long. The area was supported by 6' torque/tension bolts. The area appears to have fai... |
| 08/11/2004 | HANDLING OF MATERIALS | DAYS AWAY FROM WORK ONLY | 2d lost | Injured was lifting on the end of a 21SC floating axle to reposition it on a supply car. |
| 08/10/2004 | MACHINERY | NO DYS AWY FRM WRK,NO RSTR ACT | None | The injured was removing a small axle and gear case from an underground three wheeler with the assistance of an overhead crane. He had the gear case wired in a position in an attempt to prevent it fr... |
| 07/30/2004 | SLIP OR FALL OF PERSON | NO DYS AWY FRM WRK,NO RSTR ACT | None | Injured was crossing a belt tail piece while the belt was shut down when he slipped on the metal structure and fell landing on his posterior. The distance of the fall was approx. 18 inches. |
| 07/28/2004 | POWERED HAULAGE | NO DYS AWY FRM WRK,NO RSTR ACT | None | Injured had placed a crib under the deck of #1 21SC and in the bucket of the scoop in order to lift the SC to replace the wheel unit. The injured had positioned himself to the side of the scoop bucke... |