| 02/17/2012 | SLIP OR FALL OF PERSON | DAYS AWAY FROM WORK ONLY | 5d lost | Employee was walking beside a scoop, he tripped and fell into the blade of a bow saw lying on the scoop. The fall resulted in a laceration of the top part of his left hand requiring stitches. |
| 02/01/2012 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | A roof fall occurred in the last open x-cut in #5 entry, measuring 120'x18'x10' thick. Area was bolted with 3/4""x72"" tension rebar with T3 roof channels on 42"" ctr's. 2-10' long cable bolts are b... |
| 01/05/2012 | HANDLING OF MATERIALS | DAYS AWAY FROM WORK ONLY | 90d lost | Employee was changing crawler take-up on Joy 14CM15 miner. The gathering head pan was chained up. He placed himself under the gathering head pan to push take-up in place with his feet. The chain broke... |
| 12/07/2011 | HANDLING OF MATERIALS | NO DYS AWY FRM WRK,NO RSTR ACT | None | EE was hanging a ventilation curtain and cut his left middle finger, requiring stitches, on a CAB brattice hanger. |
| 11/08/2011 | FALL OF ROOF OR BACK | DAYS AWAY FROM WORK ONLY | 6d lost | Employee was drilling mine roof, while changing drill steel a piece of rock with a sharp edge fell striking his right arm in the fold of the elbow requiring sutures. |
| 10/13/2011 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | A roof fall occured in a 3-way intersection in #1 entry at spad no. 11248, measuring 150' x 20' x 12' thick. The area was roof bolted with 3/4"" x 6' tension rebar roof bolts with several 10' long ca... |
| 10/12/2011 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | A roof fall occured in a 4-way intersection measuring 70' x 20' x 12' thick. The area was roof bolted with 3/4"" x 6' tension rebar roof bolts with a few 8' to 12' long combination roof bolts supplem... |
| 10/12/2011 | HANDLING OF MATERIALS | DAYS AWAY FROM WORK ONLY | 53d lost | EE was cutting metal band on a pallet of Heintzmann jacks. When the band was cut, ajack rolled off the pile and struck his left foot. |
| 10/11/2011 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | A roof fall occurred in a 4-way intersection at spad no. 11278 measuring 60' x 20' x 12' in thickness. The area was bolted with 3/4"" x 6' tension roof bolts. At least 8 - 10' long cable bolts were... |
| 09/26/2011 | HANDLING OF MATERIALS | DAYS AWAY FROM WORK ONLY | 10d lost | EE was pushing/installing a 16 foot cable roof bolt when he felt pain in his right shoulder. |
| 09/21/2011 | MACHINERY | DAYS AWAY FROM WORK ONLY | 92d lost | EE was operating roof the bolter on the operator side, standing on ground. The operator man-up platform, which was chained up, fell striking his left knee. |
| 08/26/2011 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | A roof fall occurred 50 feet inby spad no. 11201 in the #5 entry in a four way intersection. The roof fall measured 40' x 20' x 10' to 12' in thickness. The area was roof bolted with 3/4"" dia. by 7... |
| 08/15/2011 | HANDLING OF MATERIALS | DAYS AWAY FROM WORK ONLY | 7d lost | EE alleged experiencing stomach muscle strain after lifting on roof bolter T-Bar. Did not start missing work until 8/18/11. |
| 08/04/2011 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | A roof fall occurred 120' inby spad #11035 in crosscut between #5 & #6 intake entries. The fall measured 50' x 20' x 6' thick and was bolted with 6' long by 3/4"" dia. tension rebar roof bolts. The... |
| 07/21/2011 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | A roof fall occurred 300' outby spad No. 10952 in the return air course. The fall measured 30'x 20'x 10' thick and was roof bolted with 3/4"" dia., 6' long tension rebar roof bolts with 8""x8"" plate... |
| 07/18/2011 | HANDLING OF MATERIALS | DAYS AWAY FROM WORK ONLY | 5d lost | Employee was repairing the high voltage cable after a copper theft at the surface substation. He dropped the PLM coupler and mashed both thumbs. |
| 07/06/2011 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | A roof fall occurred in an intake aircourse near spad No. 10819. The fall measured 120 ft. in length, 20 ft. in width and 9 ft. in thickness. The area was roof bolted with 3/4"" diameter 6 ft. and 8... |
| 06/17/2011 | FALL OF ROOF OR BACK | DAYS AWAY FROM WORK ONLY | 6d lost | A rock fell from the mine roof, striking the ATRS of the Fletcher roof bolter. When the rock hit the ATRS, employee was positioned near the rear of the bolter. The rock falling onto the machine, boun... |
| 05/24/2011 | HANDLING OF MATERIALS | DAYS AWAY FROM WORK ONLY | 30d lost | EE picked up a bag of rock dust, twisted to put on Boss Hoss. Alleged pain in his lower back. E-Doc #14116925 that was submitted 5/10/11 for alleged back injury on 4/28/11 was determined by Workers... |
| 05/06/2011 | SLIP OR FALL OF PERSON | DAYS AWAY FROM WORK ONLY | 1d lost | EE slipped and fell on mine floor from conveyor boom of shuttle car. |
| 05/03/2011 | FALL OF ROOF OR BACK | DAYS AWAY FROM WORK ONLY | 7d lost | EE was drilling a hole for a roof bolt when a piece of rock fell and hit his right forearm. |
| 04/28/2011 | SLIP OR FALL OF PERSON | DAYS AWAY FROM WORK ONLY | 4d lost | EE ALLEGES he was traveling thur a man door and tripped, then fell and ALLEGES a back injury. |
| 04/27/2011 | HANDLING OF MATERIALS | DAYS AWAY FROM WORK ONLY | 4d lost | EE was drilling mine roof, a piece of rock hit drill steel and caused steel to come out of drill chuck. The drill steel struck his left forearm. He continued working his regular scheduled shift thru... |
| 03/30/2011 | FALL OF ROOF OR BACK | DAYS AWAY FROM WORK ONLY | 3d lost | EE was moving roof bolt resin when a rock fell and struck him on his head and back. He returned to work on 3/31/11 but did not return to work on 4/4/11 due to injury. |
| 02/16/2011 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | A roof fall measured 12'long x 16' wide x 6' thick occurred in the #6 entry in the escapeway between cuts 188 & 189, 3600' outby the face area. The area was bolted with 6' tension rebar bolts and sup... |
| 02/02/2011 | FALL OF ROOF OR BACK | DAYS AWAY FROM WORK ONLY | 8d lost | EE was loading supplies on the roof bolter, when a rock fell, striking him on top of head and shoulder. |
| 01/19/2011 | HANDLING OF MATERIALS | DAYS AWAY FROM WORK ONLY | 4d lost | Employee ""ALLEGES"" that while hanging a miner cable some foreign material (rock dust) fell into his right eye. Subsequent investigation revealed the employee actually had rust in his eye from an of... |
| 01/18/2011 | OTHER | ALL OTHER CASES (INCL 1ST AID) | None | EE filed an ALLEDGED Occupational Pneumoconoiosis Claim on 1/18/11. Received notice on 4/8/11 of Claim No. 2011003387. |
| 01/08/2011 | FALL OF ROOF OR BACK | DAYS AWAY FROM WORK ONLY | 39d lost | EE was operating the left side of the roof bolter when a rock fell from the roof and struck his right ankle. |
| 01/05/2011 | HANDLING OF MATERIALS | PERM TOT OR PERM PRTL DISABLTY | 112d lost | EE felt pain in his lower right groin area when he stepped off the roof bolter he was operating. He continued working until 4:00 pm, end of shift and worked the next day, his last day worked 1/6/11. |
| 11/30/2010 | POWERED HAULAGE | DAYS AWAY FROM WORK ONLY | 4d lost | EE was assisting a co-worker to attach a belt tool trailer to a battery operated ride at break No. 41 on No. 7 roadway. While co-worker was moving the ride, EE was struck by the ride resulting in co... |
| 11/04/2010 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | A roof fall measuring 120' x 19' x 10' thick occured at spad # 10952 in the return air course. The area was bolted with 6' tension rebar bolts. |
| 09/21/2010 | HANDLING OF MATERIALS | DAYS AWAY FROM WORK ONLY | 22d lost | EE was lifting a rock that was hung between tailpiece and feeder and felt pain in the groin area. His first day missing work was 9/28/10. |
| 09/14/2010 | FALL OF ROOF OR BACK | DAYS AWAY FROM WORK ONLY | 29d lost | EE was operating the continuous miner when a piece of rock (12""x16""x4"" thick) struck his right arm above his elbow. |
| 09/01/2010 | MACHINERY | DAYS AWAY FROM WORK ONLY | 206d lost | EE ""ALLEGEDLY"" stated that while drilling the first of two holes for a 5 foot rib strap, he experienced pain in his lower back. He continued working the remainder of the shift and worked thru 9/10/... |
| 06/05/2010 | MACHINERY | DAYS AWAY FROM WORK ONLY | 2d lost | EE was installing a roof bolt and lowered the roof bolter drill pot down on his right foot. |
| 05/27/2010 | SLIP OR FALL OF PERSON | NO DYS AWY FRM WRK,NO RSTR ACT | None | EE was painting the center line on the mine roof from the top of the roof bolter when he lost his footing/balance and fell to the mine floor. Received laceration on head requiring sutures. |
| 05/27/2010 | FALL OF ROOF OR BACK | DAYS AWAY FROM WORK ONLY | 1d lost | EE was spot bolting near No. 6 belt drive when a piece of rock between two existing roof bolts fell and struck his head and left shoulder. |
| 05/06/2010 | FALL OF ROOF OR BACK | NO DYS AWY FRM WRK,NO RSTR ACT | None | EE was drilling roof in No. 3 right break when a rock, 12""x12""x2"" thick fell striking and cutting his right arm. |
| 02/25/2010 | MACHINERY | DAYS AWAY FROM WORK ONLY | 13d lost | EE started to drill a roof bolt hole and the drill steel kicked out and struck his left hand. |
| 02/23/2010 | FALL OF ROOF OR BACK | DAYS AWAY FROM WORK ONLY | 165d lost | EE was operating the roof bolter when a rock fell and struck his left forearm and wrist. Last day worked 2/25/10. |
| 02/22/2010 | FALL OF ROOF OR BACK | DAYS AWAY FROM WORK ONLY | 48d lost | EE was assisting in the installation of rib boards when a piece of coal and rock 1.5' x 1.5' x 5"" thick fell striking his right shoulder, neck and head. |
| 02/19/2010 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | A roof fall measuring 50' x 18' x 8' to 10' thick occurred in the last open crosscut of #5 entry. The area was roof bolted with 3/4"" dia. x 6' and 8' long tensioned rebar bolts. A roof bolter cable... |
| 01/29/2010 | SLIP OR FALL OF PERSON | DAYS AWAY FROM WORK ONLY | 33d lost | EE was making a shuttle car cable splice, stepped in a hole and allegedly twisted his right knee. His first day missing work was 2/6/10. |
| 01/25/2010 | SLIP OR FALL OF PERSON | DAYS AWAY FROM WORK ONLY | 4d lost | EE was walking in front of the section power center, tripped on the shuttle car power cable. In an attempt to avoid falling, his left foot became lodged along the miner cable. The fall restulted in... |
| 01/07/2010 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | A roof fall occured in the intake air course measuring 50' x 18' x 2' to 3' thick. The area was bolted with 48"" fully grouted bolts. The fall will not be cleaned up and has been breakered off. |
| 01/06/2010 | FALL OF ROOF OR BACK | DAYS AWAY FROM WORK ONLY | 83d lost | EE was installing the outer bolt of the last row in No. 1 entry when a piece of rock 2' x 4' x 4"" thick fell on his back. |
| 12/28/2009 | SLIP OR FALL OF PERSON | DAYS AWAY FROM WORK ONLY | 107d lost | Employee stepped off the rear end of the Fletcher track roof bolter and apparently twisted/injured his right knee. He continued working and his last day worked was 12/30/09. |
| 12/16/2009 | HANDTOOLS (NONPOWERED) | NO DYS AWY FRM WRK,NO RSTR ACT | None | EE was assisting co-worker in installation of a Flexco belt splice. While driving fastener rivets, he struck his left ring finger with a hammer. |
| 12/03/2009 | POWERED HAULAGE | DAYS AWAY FROM WORK ONLY | 148d lost | Employee was operating a shuttle car and allegedly ran over a rock or hit a hole in the mine floor, resulting in his head striking the shuttle car canopy. |