Maysville Mine — Accidents
Total: 152 accidents | Fatalities: 0
| Date | Classification | Injury | Days Lost | Narrative |
|---|---|---|---|---|
| 10/06/2017 | HOISTING | ACCIDENT ONLY | None | The conduit and control wiring had pulled loose from the Mine Level Door Switch. A short circuit was caused when the wires touched which in turn caused a PLC output card fault. The PLC was reset, co... |
| 05/11/2017 | HANDTOOLS (NONPOWERED) | NO DYS AWY FRM WRK,NO RSTR ACT | None | Employee was scaling a rock from the back. The scaling bar slipped and they felt pain and a burning sensation in the right shoulder. Did not report to management till 5/15/17. Had dr visit on 5/19/17,... |
| 01/17/2017 | HOISTING | ACCIDENT ONLY | None | Elevator went down finding that a wiring issue was located in the door switch. Wiring was repaired and elevator returned to full service. |
| 10/30/2016 | HOISTING | ACCIDENT ONLY | None | While cleaning rock from expansion joints in shaft a rock struck wire on the buffers knocking it loose disabling the elevator. |
| 10/04/2016 | HOISTING | ACCIDENT ONLY | None | Crews 1&2 were riding elevator when car stopped at landing. Crew 1 exited car sending crew 2 to landing. Pushed down button that sent car into over travel locking doors. Crews were removed from car at... |
| 12/31/2015 | SLIP OR FALL OF PERSON | DAYS RESTRICTED ACTIVITY ONLY | 46d restricted | Employee tripped on a piece of metal pipe that was lying on the ground. Employee tried to catch himself and jammed wrist. |
| 12/01/2015 | ENTRAPMENT | ACCIDENT ONLY | None | Elevator had stopped abruptly at approximately 45-50 feet from the top landing with production crew aboard. The braking system set automatically due to build up on rails. |
| 10/11/2015 | HOISTING | ACCIDENT ONLY | None | Elevator service was disrupted for 4 hours due to a fault in the electrical main breaker. Service was restored approximately 1:30am on October 12, 2015. |
| 03/29/2014 | HOISTING | ACCIDENT ONLY | None | During inspection of the elevator hoist a crack was found on one of the brakes shoes. System was immediately taken out of service. Repairs were made and returned to service on 3/31/2014 1:20pm. |
| 07/18/2013 | HOISTING | ACCIDENT ONLY | None | Electrical switch on the elevator door malfunctioned. This made the elevator inoperable. Elevator became operational at approximately 6:30 AM |
| 02/24/2013 | HOISTING | ACCIDENT ONLY | None | While performing a PM on the elevator a broken brake rod was discovered. This caused the elevator to be out of service. |
| 12/23/2012 | HOISTING | ACCIDENT ONLY | None | Elevator was not functioning properly. This issue persisted for more than 30 minutes. |
| 11/17/2012 | SLIP OR FALL OF PERSON | DAYS RESTRICTED ACTIVITY ONLY | 3d restricted | Employee was dismounting a loader when he twisted or pulled something in his lower back. |
| 11/12/2012 | POWERED HAULAGE | DAYS AWAY FROM WORK ONLY | 1d lost | While operating a haul truck underground the employee ran over a large rock, which jarred the operator. |
| 08/25/2012 | SLIP OR FALL OF PERSON | DAYS RESTRICTED ACTIVITY ONLY | 35d restricted | Employee was stepping up onto a concrete structure when his right knee gave out. |
| 07/05/2012 | HANDLING OF MATERIALS | DAYS RESTRICTED ACTIVITY ONLY | 5d restricted | Employee was stepping down onto a conveyor belt, he braced himself with his left wrist. When he stepped down he felt pain in his left wrist. |
| 06/30/2012 | HANDLING OF MATERIALS | NO DYS AWY FRM WRK,NO RSTR ACT | None | Employee was attempting to replace a finger at the crusher. Employee rolled his ankle, causing him to smash his pinky finger between the finger and the sidewall of the crusher. |
| 06/05/2012 | SLIP OR FALL OF PERSON | DYS AWY FRM WRK & RESTRCTD ACT | 31d lost, 62d restricted | Employee was walking in heading when he slipped and fell backwards onto his shoulder. |
| 05/14/2012 | HANDLING OF MATERIALS | DYS AWY FRM WRK & RESTRCTD ACT | 62d lost, 55d restricted | Employee was attempting to take out slack from a ratchet strap. The employee tugged with force, and the strap came free causing employee to fall backwards onto his left shoulder. |
| 03/01/2012 | HANDLING OF MATERIALS | DAYS RESTRICTED ACTIVITY ONLY | 7d restricted | Employee bent down to pick up a choker and felt a pop in his rt. knee. |
| 10/27/2011 | DISORDERS (REPEATED TRAUMA) | OCCUPATNAL ILLNESS NOT DEG 1-6 | None | Reportable Hearing Loss |
| 10/27/2011 | DISORDERS (REPEATED TRAUMA) | OCCUPATNAL ILLNESS NOT DEG 1-6 | None | Reportable Hearing Loss |
| 10/23/2011 | HOISTING | ACCIDENT ONLY | None | A rod near the brake shoe of the elevator was bent. This tripped the safety on the elevator causing it to stop. |
| 10/23/2011 | ENTRAPMENT | ACCIDENT ONLY | None | At approximately 100 Ft. down the elevator stopped with two miners aboard. The miners were stuck for approximately 1 hour at this location. |
| 10/07/2011 | HANDLING OF MATERIALS | DYS AWY FRM WRK & RESTRCTD ACT | 2d lost, 4d restricted | Employee bent over to hook fuel hose on the service truck, when he stood up he felt pain in his lower back. |
| 07/19/2011 | HOISTING | ACCIDENT ONLY | None | A switch on the elevator door was not working properly. This made the door inoperable. |
| 07/17/2011 | HOISTING | ACCIDENT ONLY | None | Limit switches were not functioning properly on the elevator. Although this impaired the elevator, the elevator could still be used to transport workers in the case of an emergency. The on-site superv... |
| 06/20/2011 | HOISTING | ACCIDENT ONLY | None | Heavy rains caused water to go down the shaft and the water damaged some electrical components of the elevator. |
| 03/15/2011 | HOISTING | ACCIDENT ONLY | None | The elevator door switch became misaligned. This issue made the elevator inoperable. |
| 01/05/2011 | HOISTING | ACCIDENT ONLY | None | An electrical issue occurred at the override portion of the elevator. This issue made the elevator inoperable. |
| 12/28/2010 | HOISTING | ACCIDENT ONLY | None | The limit switch on the elevator door was not working properly. This allowed the elevator to be inoperable for a period of time. |
| 12/28/2010 | HOISTING | ACCIDENT ONLY | None | The elevator has been recently upgraded. An employee attempted to complete a PM of the elevator in the normal manner. With the recent upgrades this method did not work (the installer of the upgrades d... |
| 11/03/2010 | SLIP OR FALL OF PERSON | DAYS RESTRICTED ACTIVITY ONLY | 42d restricted | Employee was stepping over a shaft approximately 3ft. off the ground. While doing so his foot got caught, which caused him to fall forward onto his right arm. |
| 10/18/2010 | POWERED HAULAGE | DAYS AWAY FROM WORK ONLY | 9d lost | Employee strained his back while putting on a harness style seat belt. |
| 10/11/2010 | HOISTING | ACCIDENT ONLY | None | The elevator, which is the main entrance to the mine was not working due to a faulty connection of electrical wires. |
| 08/06/2010 | HANDLING OF MATERIALS | NO DYS AWY FRM WRK,NO RSTR ACT | None | While removing an air filter from a powder truck, the employee cut his right palm on a frayed piece of metal. |
| 07/25/2010 | HOISTING | ACCIDENT ONLY | None | Regular maintenance was being performed on elevator. While changing magnetic switch, it was found to be a stonger field than original. Replaced with correct switch, which took longer than expected. Re... |
| 07/22/2010 | FIRE | ACCIDENT ONLY | None | While operating a face drill, the operator noticed flames behind her in the articulation area of the truck. The operator deployed the fire suppression system, which did not completely extingush the fi... |
| 05/09/2010 | HOISTING | ACCIDENT ONLY | None | Cleaning had been conducted on top and bottom of slope, it is believed that debris became lodged in the pulley of the elevator ropes. This allowed the ropes to become entangled and made the elevator i... |
| 04/24/2010 | HOISTING | ACCIDENT ONLY | None | The elevator door was not properly shut, which made elavator door sensor to read on and then off multiple times. This tripped the breaker on the elavator, which caused it to stop. |
| 01/21/2010 | HOISTING | ACCIDENT ONLY | None | Emergency hoist became inoperable during shaft hoist repairs. |
| 01/20/2010 | HOISTING | ACCIDENT ONLY | None | Mine emergency hoist became inoperable during shaft hoist maintenance. |
| 01/20/2010 | HOISTING | ACCIDENT ONLY | None | Mine emergency hoist became inoperable during shaft hoist maintenance. |
| 01/13/2010 | OTHER | DAYS RESTRICTED ACTIVITY ONLY | 4d restricted | Injured was walking up stairs to J-North sizer when he felt a pop in his knee. |
| 11/24/2009 | HOISTING | ACCIDENT ONLY | None | Hoist out of service after mechanical deficiencies identified. Order 6596688-01 allowed service to hoist as long as recommendations and requirements of the WG Spencer Engineering Inc. report received... |
| 10/09/2009 | HOISTING | ACCIDENT ONLY | None | Breaker tripped causing loss of power to elevator. |
| 09/16/2009 | HANDLING OF MATERIALS | NO DYS AWY FRM WRK,NO RSTR ACT | None | Injured was preparing to use water hose to wash under conveyor. Injured asked another employee to turn on the supply valve. When the valve was turned on, injured lost control of the hose which struc... |
| 08/25/2009 | HOISTING | ACCIDENT ONLY | None | Elevator door switch malfunction, caused elevator outage from 2:15pm until 8:00pm. |
| 08/05/2009 | HANDLING OF MATERIALS | DYS AWY FRM WRK & RESTRCTD ACT | 21d lost, 3d restricted | Injured was operating 11030 face scaler when it began to overheat. Injured notified service technician and shut the machine down. After waiting 15 minutes for the machine to cool down, injured opene... |
| 06/26/2009 | HOISTING | ACCIDENT ONLY | None | Conrols tripped and and needed to be reset. |