Date Classification Injury Days Lost Narrative
06/25/2004 FALL OF ROOF OR BACK ACCIDENT ONLY None AN UNINTENTIONAL ROOF FALL OCCURRED IN THE NO.1 BLEEDER ENTRY OF THE 1ST RIGHT PILLAR SECTION, ONE CROSSCUT OUTBY SURVEY STATION NO. 1664. THE FALL WAS APPROX. 70'LONG X 20'WIDE X 5'+ HIGH.
06/23/2004 FALL OF ROOF OR BACK ACCIDENT ONLY None AN UNINTENTIONAL ROOF FALL OCCURRED IN THE NO.2 BLEEDER ENTRY OF THE 1ST RIGHT PILLAR SECTION, ONE CROSSCUT INBY SURVEY NO. 1666. THE FALL WAS APPROX. 40'LONG X 18'WIDE X 4'HIGH.
02/08/2004 NO VALUE FOUND PERM TOT OR PERM PRTL DISABLTY 148d lost THE INJURED EMPLOYEE WAS BACKING A FLETCHER ROOF RANGER II ROOF BOLTER UP THE #4 ENTRY TOWARD THE FACE ONE BREAK INBY SPAD #1434. THE EE WAS OPERATING THE BOLTER FROM INSIDE THE OPERATOR DECK ON HIS K...
01/23/2004 MACHINERY NO VALUE FOUND None The continuous miner backed into shuttle car after it had been loaded and the operator was about to turn around. His feet were caught between shuttle car and rib.
01/13/2004 SLIP OR FALL OF PERSON DAYS AWAY FROM WORK ONLY 106d lost EE WAS WORKING ON THE HEAD OF A JOY 14CM-10. MINER STEPPED DOWN ONTO A HYDRAULIC HOSE LOCATED ON THE EDGE OF THE MINER PAN, SLIPPED OFF THE HYDRAULIC HOSE ONTO THE GROUND & CUT THE BACK OF HIS MIDDLE...
07/16/2003 MACHINERY NO DYS AWY FRM WRK,NO RSTR ACT None PUTTING UP BELT HANGERS DRILLED HOLE, INSERTED BOLT, TIGHTEN BOLT AND A SMALL PIECE OF ROCK FELL 13 FT HITTING DRILL HEAD ON ROOF BOLTER THEN BOUNCED AND HIT OPERATOR IN THE MOUTH RESULTING IN HIM NEE...
06/05/2003 FALL OF ROOF OR BACK ACCIDENT ONLY None RETURN PORTAL FALL.