Mine #1 — Accidents
Total: 110 accidents | Fatalities: 0
| Date | Classification | Injury | Days Lost | Narrative |
|---|---|---|---|---|
| 04/13/2000 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | A ROOF FALL OCCURRED ON THE 001-0 SECTION IN THE #4 ENTRY AT #5 BREAK. THE FALL MEASURED 20' WIDE X 25' LONG X 6' THICK. THE FALL WAS APPROXIMATELY 1400' FROM THE ACTIVE FACE. NO EQUIPMENT WAS INVOLVE... |
| 04/13/2000 | POWERED HAULAGE | NO DYS AWY FRM WRK,NO RSTR ACT | None | EE WAS A PASSENGER IN THE REAR COMPARTMENT OF A 5-TON MANTRIP. DRIVER & A FEDERAL INSPECTOR WEREIN THE FRONT COMPARTMENT. AT BREAK #6 ON 002-0 SECTION AN UNMANNED, RUN-A-WAY MANTRIP STRUCK THE 5-TON M... |
| 04/12/2000 | HANDTOOLS (NONPOWERED) | NO DYS AWY FRM WRK,NO RSTR ACT | None | EMPLOYEE WAS USING A SLEDGE HAMMER TO BREAK UP A PIECE OF SANDSTONE THAT HAD FALLEN IN THE HAULAGE ROAD. AS HE WAS STRIKING THE ROCK THE HAMMRE BOUNCED OFF THE ROCK AND STRUCK HIM ON THE LEFT SIDE OF... |
| 03/30/2000 | FALL OF ROOF OR BACK | PERM TOT OR PERM PRTL DISABLTY | None | EE WAS OPERATING THE MINE IN #3 ENTRY OF 001-0 SECTION EE BACKED THE MINOR OUT OF THE RIGHT CUT& WAS PREPARING TO CUT THE LEFT SIDE WHEN THE MINE ROOF BGAN WORKING AT THE FACE. HE WAS WAITING FOR THE... |
| 03/13/2000 | FALL OF ROOF OR BACK | NO DYS AWY FRM WRK,NO RSTR ACT | None | EMPLOYEE WAS MOUNTING A SCOOP DEFK (FEET FIRST). WHEN HE SAW A PIECE OF DRAW ROCK FALLING FROM THE MINE ROOF. EE TURNED LOOSE OF HTE SCOOP CANOPY AND FELL TO THE GROUND TWISTING HIS LEFT SHO ULDER ON... |
| 03/01/2000 | HANDLING OF MATERIALS | NO DYS AWY FRM WRK,NO RSTR ACT | None | EMPLOYEE HAD THE COVER ON THE SUPPLY CAR RAISED IN ORDER TO CHECK THE OIL AND WATER LEVELS. WHEN HE LET GO OF THE COVER TO LET IT SLAM SHUT IT STRUCK HIS RIGHT INDEX FINGER CAUSING A LACER ATION THAT... |
| 01/22/2000 | HANDTOOLS (NONPOWERED) | NO DYS AWY FRM WRK,NO RSTR ACT | None | EMPLOYEE WAS MOVING A FEEDER IN THE REHAB AREA. THE SLACK WAS TAKEN UP ON THE CATS AND SHIMS INSTALLED HOWEVER, THE PRESSURE ON THE JACKS WAS NOT FULLY RELEASED. THE GREASE INSERT USED TO TAKE UP THE... |
| 01/19/2000 | MACHINERY | NO DYS AWY FRM WRK,NO RSTR ACT | None | EE WAS OPERATING THE ROOF BOLTER, INSTALLING 8' BRUTER BOLTS. THE BOLT HOLE WAS DRILLED BUT THE DRILL STEELE WAS FOULED IN THE TOP. WHEN THE DRILL POT WAS LOWERED THE STEEL FELL FROM THE TOP S TRIKING... |
| 01/17/2000 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | A ROOF FALL HAS OCCURRED ON THE 001-0 SECTION IN THE #4 BREAK AT 5-A BELT. THE FALL MEASURED 19' WIDE, 60' LONG, AND 5' THICK. VENTILATION NOR PASSAGE OF PERSONS WAS AFFECTED AND NO INJURIES W ERE REP... |
| 01/01/2000 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | A ROOF FALL HAS OCCURRED IN THE #3 ENTRY ON THE 001-0 SECTION, 270' FROM THE ACTIVE FACE. THE ROOF FALL MEASURED 18' WIDE, 30' LONG, AND 5' THICK. VENTILATION NOR PASSAGE OF PERSONS WAS AFFECT ED AND... |