Mine #2 — Accidents
Total: 12 accidents | Fatalities: 0
| Date | Classification | Injury | Days Lost | Narrative |
|---|---|---|---|---|
| 03/09/2015 | HANDLING OF MATERIALS | DAYS AWAY FROM WORK ONLY | 3d lost | Belt boss taking out top roller of belt . Dropped caught finger between belt rail and top structure cut end of middle. Went to hospital got 17 stitches. |
| 07/14/2014 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | Roof fall on belt line 8 breaks outby #4 drive. No injuries. Fell between shifts in intersection and 1/2 through crosscuts. |
| 09/10/2012 | FALL OF ROOF OR BACK | DAYS AWAY FROM WORK ONLY | 16d lost | Roof bolting left break when piece of draw rock fell hitting employee on right hand. Went to ER cleaned & sutured hand. Had to have surgery at a later date to repair tendon on hand. |
| 12/10/2011 | POWERED HAULAGE | DAYS AWAY FROM WORK ONLY | 1d lost | Shoveling tail piece while belt was running. Belt caught shovel and pinched finger against tail piece. Mashed end of finger. |
| 07/19/2011 | MACHINERY | NO DYS AWY FRM WRK,NO RSTR ACT | None | Caught finger between steel and chuck of bolter head cutting finger. Went to ER, finger was cleaned and sutured. |
| 10/27/2010 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | At 9:50 AM on 10/27/10, an unintentional roof fall was discovered during a pre-shift examination while an MSHA inspection was on-going. The fall occurred at Spad #165 on the belt. It measured approx... |
| 10/21/2010 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | An unintentional roof fall was discovered during an MSHA inspection. (This was the third of three falls originally reported on 10/22/2010). It occurred at the #3 entry between blocks outby Spad #122... |
| 10/21/2010 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | Three unintentional roof falls were discovered during an MSHA inspection. The first occurred at the #5 entry at spad #83 (measuring approximately 6' H x 20' W x 50'L). |
| 10/21/2010 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | An unintentional roof fall was discovered during an MSHA inspection. (This was the second of three roof falls originally reported on 10/22/10). The fall occurred between #4 and #5 entries at Spad #1... |
| 10/13/2010 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | An unintentional roof fall was discovered during a pre-shift examination. The fall occurred at the #2 Entry of the Return, 1 break outby Spad #138. It measured approximately 6 -7 feet high, 20 feet... |
| 06/05/2009 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | Roof Fall: Outby spad 144 30' long, 19' wide & 4-5' thick. Ventilation not blocked. Primary escapeway blocked. |
| 06/04/2009 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | Roof fall, 60' over to right of spad 130, #8 entry intake. 50' long X 19.5' wide X 5-6' thick. No passage way blocked, no vent change, no escape routes blocked. |