Mine No 1A — Accidents
Total: 24 accidents | Fatalities: 0
| Date | Classification | Injury | Days Lost | Narrative |
|---|---|---|---|---|
| 01/05/2011 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | Rooffall on #1 Beltline top was heavily laminated in that area. Area was cribbed off to prevent any access. Production was stopped at this mine. Equipment is being pulled to the outside. |
| 12/10/2010 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | Mining in area of laminated top and stack rock. When brk was cut through area of unsupported top fell pulling two rows of bolts in the #3 entry. Test holes in all out-by and face areas did not show si... |
| 11/04/2010 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | Had a roof fall in #7 entry at brk 14 spad #73. Top is heavily laminated in area of fall. Additional cribs were built in affected area and surrounding areas. Area was completely dangered off. There we... |
| 10/26/2010 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | Had a continuation of previous fall in #4 entry brk #7 spad #28 whick took out intake stopping. Area was supported with jacks and cribs and stopping was rebuilt. Est fall 5'H-10'W-16'L. |
| 07/15/2010 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | Had fall at brk 14 spad #77 in #2 return entry. Fall was in area of laminated top. Additional cribs were installed and complete area was dangered off. Fall was approx 17' W x 20' L x 8' H. Fall was di... |
| 05/10/2010 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | Had a continuation of fall in #3 entry that occurred 11/2/09. There were no injuries. Roof is heavily laminated in this area. Additional cribs were built in surrounding areas. Fall was inspected by MS... |
| 11/20/2009 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | Roof Fall in #7 entry approx. 2000' outby section. Fall was approx. 60'long X 18' wide X 6' high.Top was heavily laminated in arch of fall. Area was cribbed and dangered off from all directions. Stopp... |
| 11/09/2009 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | A continuation of fall on 11/02/09.More cribs and timbers were added to area to danger off and added additional support. |
| 11/02/2009 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | Fall was discovered during preshift exam. Fall was in secondary escape way at brk 21 spad 109. Fall was in area of laminated top which was laced with additional support and cribs. All areas were cribb... |
| 10/12/2009 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | Had a continuation of roof fall in #2 return airways that occurred 9/9/09. Area had already been cribbed and dangered off. Additional cribs and dangered off boards were installed to keep people out o... |
| 03/05/2009 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | Had a portion of roof fall in #3 entry while mining. Roof contained surface cracks which were not visible due to mixed laminated top which was stuck to sandstone roof. Rock was approx. 3' to 4' in wid... |
| 02/10/2009 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | Had roof fall in #2 rm, 3 brks outby spad #320 in return airway. Top had several surface cracks and water was coming from cracks. Top had lamination of sandstone and slate. |
| 10/21/2008 | MACHINERY | DAYS AWAY FROM WORK ONLY | 173d lost | Operator dropped drill wrench in cradle of bolter. Operator kept raising and lowering pot until wrench was free - this action caused damage to machine - when he removed his wrench the boom on machine... |
| 10/06/2008 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | Had roof fall approx 15'L8'W3'H. in our #7 entry 1 brk inby spad #26 in intake airway approx. 20 brk. Outby working faces. Top was heavily Laminated. Additional cribs and headers were installed to mak... |
| 09/09/2008 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | Had roof fall in return entry #2 at brk 10-11 inby spad #39. Fall was approx 6'H X 18'W X 50'L. Fall occurred in a cribbed area. Area has been completely cribbed and dangered off. |
| 09/06/2008 | FALL OF ROOF OR BACK | DYS AWY FRM WRK & RESTRCTD ACT | 66d lost, 48d restricted | Kettle bottom and some draw rock fell in the intersection of #2 entry and hit EE in the back of his calf, causing a laceration on his right leg. |
| 07/15/2008 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | Had a continutation of fall reported on 7-12-08 extending thru intersection atBrk #8 #4 Entry across to #5 Entry. Approx. 40' by 20' by 5'. Area was examined by both Federal roof control inspectors an... |
| 07/12/2008 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | Had roof fall in #4 at bak #8 1 brk inby soad #28 fall measured 20'L by 20'W by 6'H. Fall occured approx. 14 brks outby working section. |
| 06/04/2008 | POWERED HAULAGE | NO DYS AWY FRM WRK,NO RSTR ACT | None | Man was operating shuttle car and hit rib knocking off a small piece of coal which struck his hand causing a laceration on index finger. |
| 05/12/2008 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | Had fall in #7 entry brk 10 1 brk inby spad 43. Fall was approx 11 brks outby section 001 in intersection & hdg, measuring 25' x 20' w x 6' high. Area of laminated roof conditions. Areas have been hea... |
| 05/11/2008 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | Had fall in #5 entry brk #9 2 brks inby spad 27. Fall was approx 12 brks outby 001 section in intersection & hdg, measuring 35' L x 20' W x 6' H. Fall was in area of laminated top. |
| 04/01/2008 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | Had roof fall in #7 Entry - 6 brks outby working section. fall measures 5' by 5' across left side of intersection by 5' by 5' by 20' on inby corner. |
| 03/14/2008 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | Fall occurred in the #7 hdg 30' inby spad #54 to the face. Approx 55' in length by 18' in width by 6'-9' in height. A clean up plan will be posted. Reviewed with crew and submitted for approval with O... |
| 02/22/2008 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | Had fall in #6 Entry in last open crosscut. Fall is approx. 6' thick by 50' in length covering 20' outby last x-cut extending thru brk. and inby 15'. |