Mine No. 26 — Accidents

Total: 7 accidents | Fatalities: 0

Date Classification Injury Days Lost Narrative
04/16/2013 FALL OF ROOF OR BACK ACCIDENT ONLY None A sand stone slab fell between #4 and #5 entries approx. 18' x 20' - #4 entry was cribbed at the intersection and had 8 Heintzman jacks set along travel way.
08/24/2012 SLIP OR FALL OF PERSON DYS AWY FRM WRK & RESTRCTD ACT 27d lost, 31d restricted A 3rd shift crew was assigned to advance the belt one break. They had trammed the feeder out of the way and were in the process of moving the feeder cable when an ee pulling the feeder cable received...
03/04/2012 FALL OF ROOF OR BACK ACCIDENT ONLY None A roof fall was discovered during the pre-shift exam on 03/04/12. The fall is located near spad 1071. The fall measured 50 feet x 18 feet x 8 feet in thickness and was laminated shell roof. No escapew...
10/04/2011 FALL OF ROOF OR BACK ACCIDENT ONLY None A ROOF FALL was discovered two breaks outby survey station 929 between the #6 & #7 entries. The fall measured 70' in length, 20' in width and 9 to 11 feet in thickness. The area was bolted with 42"" r...
08/10/2011 FALL OF ROOF OR BACK ACCIDENT ONLY None A ROOF FALL was discovered on the 4th south panel. The fall is located across from spad #847 in the neutral entry intersection. The fall measures approximately 60 feet in length, 19-20 feet in width a...
11/09/2010 HANDLING OF MATERIALS NO DYS AWY FRM WRK,NO RSTR ACT None During the process of coupling a supply car to a scoop, the employee's ring finger on his right hand was caught between the coupling pin and the bumper of the scoop, resulting in a laceration.
02/02/2010 FALL OF ROOF OR BACK ACCIDENT ONLY None A ROOF FALL was discovered in the No. 5 Entry at survey station No. 454. The fall occurred in an intersection and measured approximately 20' wide X 24' long X 5' - 8' thick.