Morton Salt Fairport Mine — Accidents
Total: 312 accidents | Fatalities: 0
| Date | Classification | Injury | Days Lost | Narrative |
|---|---|---|---|---|
| 12/11/2012 | SLIP OR FALL OF PERSON | DAYS RESTRICTED ACTIVITY ONLY | 19d restricted | Employee was descending a roof bolter; took one step onto the mine floor and tripped on the stab jack and fell on his bottom. |
| 11/05/2012 | HOISTING | ACCIDENT ONLY | None | The production skip (north) hung-up in scrolls and bent the bottom part of the skip. All miners evacuated with no injuries or other issues. The skip was replaced due to damage and put back into servic... |
| 10/31/2012 | HOISTING | ACCIDENT ONLY | None | During the weekly shaft inspection of the production hoist power was lost to the mine at approximately 4:45 AM. An off-site power line was knocked down during a storm resulting in the mine losing powe... |
| 10/31/2012 | HOISTING | ACCIDENT ONLY | None | A PLC Emergency Stop Fault on the Koepe Drive would not clear after power tripped. Power was lost to the Koepe Hoist while three employees were underground attempting to restart the main fan. The empl... |
| 10/23/2012 | HANDLING OF MATERIALS | DAYS AWAY FROM WORK ONLY | 37d lost | Employee incurred a broken nose after being struck by a 2"" waterline. The employee was moving the waterline and other utilities to prepare the back to be mechanically scaled. While the employee was i... |
| 08/10/2012 | HOISTING | ACCIDENT ONLY | None | A neighboring facility operator struck a power line knocking power to our facility. All employees evacuated the mine under a non-emergency conditions by way of our Koepe Hoist. Power was restored at a... |
| 07/26/2012 | HOISTING | ACCIDENT ONLY | None | Towards the end of second shift the hoist (Koepe)final stop switch failed. This shut down the hoist creating an evacuation due to not having two escape ways to surface. The mine was evacuated with no... |
| 06/21/2012 | HOISTING | ACCIDENT ONLY | None | Towards the end of 1st shift the production hoist tripped out due to an auxiliary contactor in the hoist house control panel. This shut the hoist down creating an evacuation due to not having two esca... |
| 05/25/2012 | HOISTING | ACCIDENT ONLY | None | Towards the end of 2nd Shift the North Skip got hung up in the scrolls damaging the hoist. This shut down creating an evacuation due to not having two escape ways to surface. The mine was evacuated wi... |
| 05/22/2012 | HOISTING | ACCIDENT ONLY | None | During the weekly Hoist inspection the shaft crew found a spring on the south skip that needed replaced. The mine was evacuated to perform the work and the crew went ahead an replaced the whole south... |
| 04/16/2012 | HOISTING | ACCIDENT ONLY | None | Early into 2nd shift the hoist (Koepe) tripped out due to low air in the compressor. This shut the hoist down creating an evacuation due to not having two escapeways to surface. The mine was evacuated... |
| 04/10/2012 | HOISTING | ACCIDENT ONLY | None | Towards the end of the shift the Hoist (Koepe) kicked out on high amps. This shut the hoist down creating an evacuation due to not having two escapeways to surface. The mine was evacuated with no inju... |
| 04/02/2012 | HOISTING | ACCIDENT ONLY | None | The Koepe counterweight came out of the guides at the Koepe bottom area. The mine was evacuated and repairs were made and test were completed. The Koepe was put back in service on 4/3/2012 at 6:00 am.... |
| 03/16/2012 | HOISTING | ACCIDENT ONLY | None | Towards the end of the shift there was a fault in the auxiliary contactor on the north skip. This shut the hoist down creating an evacuation due to not having 2 escape ways to surface. The mine was ev... |
| 01/23/2012 | HOISTING | ACCIDENT ONLY | None | Towards the end of the shift the Dynamic Breaking Contactor on the hoist was not working properly. This shut the hoist down creating an evacuation situation due to not have 2 escape ways to surface. M... |
| 01/17/2012 | HOISTING | ACCIDENT ONLY | None | Due to a power outage, power was lost to the mine. Mine evacuated via auxiliary power. No injuries or other problems. There was no damage to hoisting equipment - Production or Man Hoist. |
| 12/21/2011 | HOISTING | ACCIDENT ONLY | None | The Koepe resync motor burned up causing the conveyance to be down for more than 30 minutes. Mine evacuated via production shaft. No injuries or other problems. Koepe resync motor replaced and Koepe p... |
| 11/17/2011 | HOISTING | ACCIDENT ONLY | None | In the middle of the shift the hoist pin broke on the I contact. This shut the hoist down creating an evacuation situation due to not having 2 escape ways to surface. Mine Evacuated. No injuries or ot... |
| 11/10/2011 | SLIP OR FALL OF PERSON | DAYS RESTRICTED ACTIVITY ONLY | 12d restricted | Employee standing on uneven ground attempting to pull a 13kva cable over a large salt chunk to move it out of the roadway. He lost footing and creeled his right ankle. |
| 11/03/2011 | HOISTING | ACCIDENT ONLY | None | Broken bolts on the main production hoist contactor would not allow the contact to close in the switch. Mine evacuated. No injuries or other problems. After troubleshooting to find problem, hoist rel... |
| 10/17/2011 | HANDLING OF MATERIALS | DAYS RESTRICTED ACTIVITY ONLY | 14d restricted | Employee felt pain in back while removing 25lb tool bag from shelf. As employee was removing the bag, the bag slipped from his grasp and he attempted to grab the bag and experienced the pain in his ba... |
| 10/02/2011 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | While performing mine checks, Foreman came upon roof fall in the 4North area(2A-6 block).The fall dimensions were approximately 40-45' X 70-75' X 0- 12'. There were no injuries or equipment involved.... |
| 08/01/2011 | ENTRAPMENT | ACCIDENT ONLY | None | DC power supply for electric brake failed, locking brake on man cage when 150' from bottom coming up with 3 persons aboard. Mine evacuated via production shaft. After PC software troubleshooting, cage... |
| 07/25/2011 | HOISTING | ACCIDENT ONLY | None | Early into the midnight shift, the gate for the North skip failed to close. This shut the hoist down creating an evacuation situation due to not having 2 escape ways to surface. Mine evacuated. No inj... |
| 06/28/2011 | HANDTOOLS (NONPOWERED) | NO DYS AWY FRM WRK,NO RSTR ACT | None | Employee was using a screwdriver to tighten hose clamp on ANFO rig. Screwdriver slipped causing clamp to turn and cause injury requiring sutures. This injury being reported as MEDICAL TREATMENT only. |
| 06/15/2011 | HOISTING | ACCIDENT ONLY | None | During hoisting, latch arm on N skip allowed skip gate to open when skip going down, and damaged gate. Hoisting stopped; mine evacuated; NO injuries or other problems. Day shift crews sent home. |
| 06/14/2011 | HOISTING | ACCIDENT ONLY | None | During hoisting, a switch malfunction allowed skip gate to get out of sequence and catch on crossmember support in headframe and caused slack rope that stopped hoist. After investigation, slack rope... |
| 05/17/2011 | HOISTING | ACCIDENT ONLY | None | A malfunction in the electric powered air valve for the N gate of the production shaft skip pocket locked in the open position. Due to trouble-shooting and repair time, the mine was evacuated. No inju... |
| 03/23/2011 | MACHINERY | NO DYS AWY FRM WRK,NO RSTR ACT | None | Employee was in process of retrieving grease gun when the hose was caught accidentally in gearing where inspection cover/guard had partially vibrated open without his knowledge. The gearing caught th... |
| 03/11/2011 | SLIP OR FALL OF PERSON | DAYS AWAY FROM WORK ONLY | 89d lost | Employee tripped on bottom 2 of 5 steps exiting toilet facility. |
| 03/04/2011 | HANDLING OF MATERIALS | DAYS RESTRICTED ACTIVITY ONLY | 40d restricted | Employee strained shoulder handling 50# salt bags on 3/4/2011. Worked rest of week. Sought medical attention and began duty restrictions on 3/14/2011. |
| 02/02/2011 | HOISTING | ACCIDENT ONLY | None | Due to an area electrical outage, power was lost to the mine. After trouble-shooting to re-set power, a problem existed with the man cage. Mine evacuated. No problems; no injuries. Power restored to... |
| 01/12/2011 | HOISTING | ACCIDENT ONLY | None | After 1st midnight crew had entered mine, a problem occurred in the PC controller for the man cage. It would operate on manual, but not automatic. After 3 attempts, it was decided to evacuate the 16 p... |
| 11/30/2010 | ELECTRICAL | ACCIDENT ONLY | None | Due to an electrical storm in the area, the mine site (along with others in the area) lost electrical power. Mine evacuated via auxiliary power source. No injuries or other problems. Power restored a... |
| 10/26/2010 | SLIP OR FALL OF PERSON | DAYS RESTRICTED ACTIVITY ONLY | 3d restricted | Employee stumbled when stepping into the maintenance parts building and fell, striking his right knee and right lower leg on the building floor. |
| 08/24/2010 | HOISTING | ACCIDENT ONLY | None | A malfunction occurred with the lower limit switch for the access cage. In trying to remedy the problem with controls on manual which caused the lily controls got ""out of sync"". The mine was evacu... |
| 07/09/2010 | HOISTING | ACCIDENT ONLY | None | The main power supplier ""lost"" a nearby substation, causing power outage to mine. Switch was made to a local supplier to operate access cage for evacuation of 17 persons in mine. No injuries or othe... |
| 07/06/2010 | HOISTING | ACCIDENT ONLY | None | During normal hoisting on 3rd shift, a portion of leaky feeder cable became entangled on the South skip. The North skip is part of secondary escapeway, but mine was evacuated so cable could be removed... |
| 06/29/2010 | HANDLING OF MATERIALS | DYS AWY FRM WRK & RESTRCTD ACT | 9d lost, 222d restricted | Employee was injured while removing metal screen from salt processing plant. The screen was stuck in position and he jerked on it and felt pain in his right wrist. He continued working his regular s... |
| 06/25/2010 | HOISTING | ACCIDENT ONLY | None | The South hoist drum brake spring was broken; management chose to make a repair. This was near end 3rd shift; allowed crews to exit during shift change. Repair completed; test done; 1st shift into min... |
| 06/21/2010 | HOISTING | ACCIDENT ONLY | None | An electrical malfunction (blown 4160v fuse) caused a shutdown of the Production Hoist (part of secondary escapeway). Mine was evacuated; no problems, no injuries. Hoist back in service at 4:30am. |
| 05/10/2010 | SLIP OR FALL OF PERSON | DAYS AWAY FROM WORK ONLY | 123d lost | Employee reported injury on 5/11/10 that he had sprained his ankle getting out of operator compartment of lube truck. He continued working his regular shift. He There were no major complaints up thro... |
| 04/30/2010 | HOISTING | ACCIDENT ONLY | None | During access shaft cage pre-shift (for 2nd shift) two locations on balance rope were discovered to be damaged. Decision made to change rope. Mine evacuated. No injuries or other problems. |
| 03/20/2010 | HANDTOOLS (NONPOWERED) | DAYS RESTRICTED ACTIVITY ONLY | 7d restricted | Employee was in process of removing the front drive hub from a battery haulage equipment. He was using a pry bar to remove the hub from the axle shaft. As he jerked on the pry bar, he felt a sharp p... |
| 02/15/2010 | HOISTING | ACCIDENT ONLY | None | After some non-related start-up problems at beginning of shift, the newly installed skip began binding in the scroll plate. Finally, it stuck and would not move. The mine was evacuated; no injuries;... |
| 01/25/2010 | HOISTING | ACCIDENT ONLY | None | Access cage lowered to sump. After troubleshooting, determination of faulty lower limit switch. Switch replaced, but was bad. Installed another switch. During investigation, found foreign material on... |
| 01/20/2010 | HOISTING | ACCIDENT ONLY | None | Access cage experienced problem with lower stop switch. After changing switch & extensive investigation when that didn't fix, a slightly bent support arm for switch was discovered. Mine evacuated; no... |
| 01/18/2010 | HOISTING | ACCIDENT ONLY | None | The man cage lily control went out of sync due to faulty lower limit switch. Mine was evacuated. After trouble-shooting, it was corrected and placed back in service for the next shift. No injuries or... |
| 01/13/2010 | HOISTING | ACCIDENT ONLY | None | An electrical contactor failed on the production hoist. Quite some time involved in locating specific unit. Employees evacuated from mine. Problem found and repaired. Hoist back in service at 11:00pm.... |
| 12/03/2009 | HOISTING | ACCIDENT ONLY | None | A brake switch malfunctioned on Koepe mancage. After switch replacement and weight testing, mancage still wasn't stopping at upper level properly. Trouble-shooting continued. Brake pads re-adjusted.... |