Mountain Fork No 1 — Accidents
Total: 11 accidents | Fatalities: 0
| Date | Classification | Injury | Days Lost | Narrative |
|---|---|---|---|---|
| 01/16/2008 | FALL OF ROOF OR BACK | DAYS AWAY FROM WORK ONLY | 2d lost | Employee was bolting top. When he started his drill steel, a piece of rock broke out from the top and hit him in the nose. |
| 08/02/2007 | FALL OF FACE/RIB/PILLAR/SIDE/HIGHWALL | DAYS AWAY FROM WORK ONLY | 6d lost | Employee was running #2 Miner in the #6 Block, mining final left when a browl broke loose & fell on his left lower leg; sent employee to have x-ray, nothing broken. |
| 07/31/2007 | POWERED HAULAGE | DYS AWY FRM WRK & RESTRCTD ACT | 18d lost, 11d restricted | The 3 wheeler mantrip operator lost a wheel bearing, causing the brakes to fail. When operator jumped off, he bruised his left shoulder & broke (1) rib bone. |
| 09/11/2006 | SLIP OR FALL OF PERSON | NO DYS AWY FRM WRK,NO RSTR ACT | None | Was walk-into acrosscut slip & fell on rock botton brushing her tailbone. |
| 08/16/2006 | POWERED HAULAGE | DAYS AWAY FROM WORK ONLY | 5d lost | Belt man was traveling #2 haulway, lost his footing on brake pedal and slid in to the rib brushing chest area; still finished his shift. |
| 06/06/2006 | HANDLING OF MATERIALS | DAYS AWAY FROM WORK ONLY | 4d lost | Taking miner and water line, water line fell on employee's left shoulder causing a dislocation. |
| 04/12/2006 | MACHINERY | NO DYS AWY FRM WRK,NO RSTR ACT | None | Injured EE and co-worker were hanging miner cable, when the cable that the two men were hanging was pulled down by machine operator, pulling extra cable. |
| 04/12/2006 | MACHINERY | DAYS AWAY FROM WORK ONLY | 295d lost | Two employees were hanging miner cable when the cable was pulled down by the machine operator pulling up extra cable. |
| 03/20/2006 | POWERED HAULAGE | DAYS AWAY FROM WORK ONLY | 22d lost | Hurt shoulder on ride going through low top on roadway. |
| 09/13/2005 | POWERED HAULAGE | DYS AWY FRM WRK & RESTRCTD ACT | 120d lost, 40d restricted | THE INJURED EE WAS WALKING FROM THE POWER CENTER ENTRY TO CHECK THE DISCHARGE END OF THE FEEDER. WHEN HE WALKED ALONG THE EDGE OF THE FEEDER, HE LOST HIS FOOTING AND THE CONVEYOR CHAIN CAUGHT HIS LEFT... |
| 12/16/2001 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | FAULT IN STRATA THAT COULD NOT BE DETECTED DURING REGULAR BOLTING CYCLE AND ALSO HAD TENSION CRACKS IN THE ROOF. ADDITIONAL SUPPORT WAS INSTALLED IN THE AREA. |