No. 7 — Accidents

Total: 12 accidents | Fatalities: 0

Date Classification Injury Days Lost Narrative
10/09/2008 FALL OF ROOF OR BACK ACCIDENT ONLY None Rider seam came closer to the mining seam.
06/20/2007 FALL OF ROOF OR BACK ACCIDENT ONLY None Roof fall occurred starting 1800 ft inby no. 2 portal on the 1st belt line, Ranging 4 to 6 ft highh approx 14 ft wide and 30 to 40 ft long in between the blocks of break 17 and 18.
06/13/2007 FALL OF ROOF OR BACK ACCIDENT ONLY None Roof fall occurred starting 1,200' inby #3 portal on the intake entry. The fall was approx 20' wide X 150-200' long X 10-20' high in between the coal block and through 2 intersections.
02/12/2007 POWERED HAULAGE DAYS AWAY FROM WORK ONLY 6d lost Backing up mantrip to pick up employees - ran into water tank bursting it then ricocheting into pump house causing injury to right pinky finger.
02/07/2007 FALL OF ROOF OR BACK DAYS AWAY FROM WORK ONLY 12d lost Peice of draw rock fell hitting left side of head, left shoulder and back.
12/02/2006 FALL OF ROOF OR BACK ACCIDENT ONLY None A non-injury foof fall has occurred in the intersection measuring about 18 foot wide and 22 foot in length from 2 to 7 foot in height.
08/28/2006 FALL OF ROOF OR BACK DAYS AWAY FROM WORK ONLY 24d lost Pulled shuttle car up behind miner loading coal. a rock came over sideboards hitting him in nose and right arm.
08/18/2006 FALL OF ROOF OR BACK ACCIDENT ONLY None Roof fall occurred starting 1,200 ft inby #2 portal belt entry. The fall was approx 20 ft wide, 40 ft long, 7 ft high in between the coal blocks.
02/01/2006 HANDTOOLS (NONPOWERED) DAYS AWAY FROM WORK ONLY 12d lost Cutting open a box of glue-box cutter slipped cutting r-thumb.
10/11/2005 FALL OF FACE/RIB/PILLAR/SIDE/HIGHWALL DAYS AWAY FROM WORK ONLY 1d lost Cleaning up belt line with scoop, got too close to rib rock rolled out and hit him.
03/22/2005 FALL OF ROOF OR BACK ACCIDENT ONLY None An unintentional roof fall was discovered in the #2 entry one break in by spad #58. Size estimated to be 75' l by 18-20' w by 8-10' h. The area had been supported with 6 foot torque tension bolts with...
07/26/2004 FALL OF ROOF OR BACK ACCIDENT ONLY None An unintentional rock fall was discovered in #5 entry at #11 break. Size of fall estimated: 4 1/2'H x 20'W x 20'L. Area had been supported with 4' fully grouted resin bolts with additional support con...