Riola Complex Vermilion Grove Portal — Accidents
Total: 275 accidents | Fatalities: 0
| Date | Classification | Injury | Days Lost | Narrative |
|---|---|---|---|---|
| 07/06/2002 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | MAIN NORTH, STATION # 17+54, X-CUT FROM #6 ENTRYTO #7 ENTRY FELL FOR 20'X 25'X 5'HIGH. |
| 07/06/2002 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | MAIN NORTH STATION #20+85, X-CUT FROM #6 ENTRY TO #7 ENTRY FELL FOR, 20'X 30'X 5'HIGH. |
| 07/02/2002 | POWERED HAULAGE | DAYS AWAY FROM WORK ONLY | 7d lost | MAN WAS SHOVELING, GOT IN THE COAL HAULER & HIT SOME BUMPS. |
| 05/29/2002 | MACHINERY | DAYS AWAY FROM WORK ONLY | 43d lost | ROCK MEASURING 6' X 5' X 5"" FALL JUST INBY LAST ROW OF BOLTS, STRIKING MAN IN THE LEG. |
| 05/10/2002 | MACHINERY | DAYS AWAY FROM WORK ONLY | 33d lost | A DRILL STEEL WAS STUCK IN THE MINE ROOF, WHEN IT FELL OUT IT STRUCK EE IN THE LEFT INDEX FINGER. |
| 04/29/2002 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | A ROOF FALL OCCURED IN ROOM #2 SURVEY STATION 0+60- 1+20 IN THE 1ST LEFT ROOMS OFF OF THE N.W. ENTRIES. MEASURING 20'WIDE, 80'LONG, 5'THICK. ALL APPROACHES TO THIS AREA WILL BE TIMBERED OFF. |
| 04/29/2002 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | A ROOF FALL OCCURRED IN THE #6 ENTRY SURVEY STATION 12 AND 20 OF THE NORTH WEST ENTRIES MEASURING 30' L BY 8' W BY 5' HIGH. THIS AREA WILL BE TIMBERED OFF. |
| 04/27/2002 | MACHINERY | DAYS AWAY FROM WORK ONLY | 1d lost | A SLAB OF ROCK SLID OFF OF THE CONTINUOUS MINER STRIKING EE IN THE LEG. |
| 04/26/2002 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | A ROOF FALL OCCURRED IN ROOM #3, SURVEY STATION 2+40, 1ST LEF ROOMS OFF OF THE NW ENTRIES, MEASURING 30' X 20' X 5'. ALL APPROACHES TO THE FALL WILL BE TIMBERED. |
| 04/24/2002 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | A ROOF FALL OCCURED IN ENTRY #3 SURVEY STATION 9 & 80 OF THE N.W. ENTRIES MEASURING 20' H X 20' W X 12' HIGH ALL APPROACHES WERE TIMBERED. |
| 04/22/2002 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | A ROOF FALL OCCURRED IN ENTRY #2 SURVEY STATION 5+40 NW ENTRIES MEASURING 70' L X 19' W X 12' H. ALL APPROACHES ARE BEING TIMBERED UP. |
| 04/19/2002 | HANDLING OF MATERIALS | DAYS AWAY FROM WORK ONLY | 90d lost | MAN WAS ATTEMPTING TO GET A PIECE OF HEAVY SHEET METAL FROM BEHIND OTHER SHEET METAL ON THE RACK. SEVERAL PIECES OF SHEET METAL FELL ON HIS FOOT. |
| 04/16/2002 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | ROOF FALL OCCURED. WAS TIMBERED OFF TO PREVENT RECURRENCE. |
| 04/12/2002 | FALL OF ROOF OR BACK | DAYS AWAY FROM WORK ONLY | 70d lost | THE EE WAS LOADING A ROCK DUSTER WHEN A PIECE OF ROCK FELL FROM THE ROOF AND STRUCK HER ON THE HEAD AND RIGHT SHOULDER. |
| 04/12/2002 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | A ROOF FALL OCCURED A SURVEY STATION 13 & 40. ENTRY 3 N.W. PANEL ENTRIES MEASURING 20X 15X 6. ALL APPROACHES HAVE BEEN TIMBERED OFF. |
| 04/12/2002 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | A ROOF FALL OCCURRED AT SURVEY STATION 3 AND 60 ENTRY #3 IN THE NW PANEL ENTRIES. THE FALL MEASURED 10' BY 30' BY 15'. ALL APROACHES ARE TIMBERED OFF. |
| 04/05/2002 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | ALL APPROACHED TO THE ROOF FALL HAVE BEEN TIMBERED AT THIS TIME. |
| 04/02/2002 | HANDLING OF MATERIALS | NO DYS AWY FRM WRK,NO RSTR ACT | None | EMPLOYEE HAD BEEN WATERING BATTERIES AND IT HAD MADE HIS BACK SORE. |
| 02/04/2002 | HANDLING OF MATERIALS | NO DYS AWY FRM WRK,NO RSTR ACT | None | EE BENT OVER TO PICK UP ROOF BOLTS AND FELT SOMETHING PULL & POP IN HIS LOWER BACK. |
| 01/08/2002 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | A ROOF FALL OCCURED IN ENTRY #1 SURVEY STATION 5 & 00 OF THE WEST MAINS THE FALL WAS 5 FEET HIGH BY 20 FT LONG X 20 FT WIDE IT HAS BEEN TIMBERED AT ALL APPROX. |
| 01/01/2002 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | A ROOF FALL HAS OCCURRED IN ENTRIES 4 AND 5 OF THE WEST MAINS STATION 5 & 00. THE FALL IS 120' LONG BY 20' WIDE BY APPROX. 6' HIGH ALL APPROACHES TO THE AREA HAS BEEN TIMBERED OFF. |
| 11/27/2001 | SLIP OR FALL OF PERSON | NO DYS AWY FRM WRK,NO RSTR ACT | None | TYING OFF SAFETY LINES INSIDE OF PREP PLANT. WHEN HE SLIPPED OFF CONDUIT HE WAS STANDING ON. AND FELL ON SAME CONDUIT. |
| 11/26/2001 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | A ROOF FALL OCCURRED IN #5 ENTRY AT 4+00 ON MAINNORTH. AREA WAS BOLTED WITH 5'INSTALL III BOLTS WITH 2' OF RESIN. ROOF FALL WILL BE CLEANED UP &REBOLTED. FALL WAS 18'W X 17'L X 6'H. |
| 08/24/2001 | FALL OF FACE/RIB/PILLAR/SIDE/HIGHWALL | DAYS AWAY FROM WORK ONLY | 34d lost | EE WALKED ON FORM WALL ONTO CONCRETE WALL FALLING APPROX 10 FEET. |
| 06/18/2001 | SLIP OR FALL OF PERSON | DAYS AWAY FROM WORK ONLY | 20d lost | EMPLOYEE WAS PULLING AN ELECT. CABLE INTO AN OPEN PIT, HIS RIGHT FOOT SLIPPED INTO A WASHOUT AND SPRAINED HIS RIGHT ANKLE. |