Ruby Energy — Accidents
Total: 284 accidents | Fatalities: 2
| Date | Classification | Injury | Days Lost | Narrative |
|---|---|---|---|---|
| 02/11/2009 | HANDLING OF MATERIALS | DAYS AWAY FROM WORK ONLY | 17d lost | Injured was removing panel from c/m and cut left ring finger, he received stitches. |
| 02/11/2009 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | A roof fall was discovered by the fireboss and MSHA inspector while making the return entries. The fall measured 120 ft in length x 19 ft in width x 10 ft high. It is appx. 7,900 ft from the section i... |
| 02/11/2009 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | An unplanned roof fall was discovered by fireboss & MSHA inspector while traveling the return. The fall measured 100 ft in length x 19 ft in width x 7 ft high. 15,000 ft from the section. 3 x-cuts inb... |
| 02/11/2009 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | An unplanned roof fall was discovered by fireboss & MSHA inspector in a neutral entry App. 10,500 ft from the section in the # 2 entry at spad # 406. The area is dangered off. The fall measured 120 ft... |
| 01/23/2009 | HANDTOOLS (NONPOWERED) | NO DYS AWY FRM WRK,NO RSTR ACT | None | Injured was making a belt splice and the knife slipped causing a laceration on the left index finger. Required 6 stitches. |
| 01/22/2009 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | An unplanned roof fall was discovered on a weekly exam on 1/22/09 measuring 60' in length, 19' in width & 8' in height at spad #3031 approx. 3500' from the working face. Entrances have been dangered &... |
| 01/16/2009 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | An unplanned roof fall was discovered in the #1 entry, approx 3000' outby the #1 working section. All enterances were dangered off and this area will not be rehabilitated. This area was bolted with 6'... |
| 01/13/2009 | POWERED HAULAGE | DAYS AWAY FROM WORK ONLY | 260d lost | Injured was tramming a scoop in # 5 entry & a rail came into the deck and caught his cover alls and struck him in the back causing a fracture to his shoulder blade. |
| 01/08/2009 | MACHINERY | NO DYS AWY FRM WRK,NO RSTR ACT | None | Injured was struck by a piece of rock in the back as he went forward. His face hit the miner and he broke a tooth. |
| 01/06/2009 | FALL OF ROOF OR BACK | NO DYS AWY FRM WRK,NO RSTR ACT | None | Injured was walking in the primary escape way and bumped his head against the roof, causing a small piece of rock to fall, stiking him on the left hand. This accident caused a fracture to his left ind... |
| 12/28/2008 | HANDLING OF MATERIALS | DAYS AWAY FROM WORK ONLY | 43d lost | Injured was helping set an H beam. As the beam was slid, it twisted striking him on the knee causing him to twist his right knee. Note: He worked until 5 am & then went to Dr. He was given a release t... |
| 12/23/2008 | STRIKING OR BUMPING | NO DYS AWY FRM WRK,NO RSTR ACT | None | Injured was walking and a cable b0h hanging from the roof caught his left ear causing a laceration requiring stitches. |
| 12/15/2008 | FALL OF FACE/RIB/PILLAR/SIDE/HIGHWALL | NO DYS AWY FRM WRK,NO RSTR ACT | None | Injured was installing a roof bolt when a piece of rock fell from the rib striking him in the low back causing a fracture to the L1 and L2 veatcabled. |
| 12/06/2008 | HANDLING OF MATERIALS | DAYS AWAY FROM WORK ONLY | 42d lost | Injured was unloading crib blocks & 1 fell from the stack striking his left hand, causing a fracture to the index finger. Amended: Injured followed up on 12-15-08 with orthopedic & returned to work wi... |
| 12/06/2008 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | At 8:10 am an unplanned roof fall was discovered measuring 30 ft in length x 20 ft. in width x 8 ft. in height. This area was dangered off and will be rehabilitated. The fall was called in and investi... |
| 12/03/2008 | FALL OF ROOF OR BACK | NO DYS AWY FRM WRK,NO RSTR ACT | None | Employee was moving the roof bolter when a piece of rock fell from the roof measuring 12"" x 12"" x 1"" thick striking his left hand causing a laceration on the 3rd & 4th fingers. He received stitches... |
| 10/07/2008 | FALL OF ROOF OR BACK | DAYS AWAY FROM WORK ONLY | 80d lost | Injured stated he was struck in right knee with a piece of rock causing a sprain to his knee. Injured was given a full release & worked up till a follow up visit on 10-20-08. At that point the orthope... |
| 10/07/2008 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | Unplanned fall on the #4 track entry measuring 60 ft in length x 19 ft in width x 6 ft high. The area was breakered off and is being rehabed. The fall was investigated by person from WV OMSH & T and f... |
| 10/06/2008 | HANDTOOLS (NONPOWERED) | NO DYS AWY FRM WRK,NO RSTR ACT | None | The injured cut himself with a utility knife just below the left knee. He received stiches at the E/R. |
| 09/22/2008 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | An unplanned roof fall was discovered on 9/22/08 in the return app. 3400ft from the #2 section measuring 30' in length x 15' in width and 6' high. The area had 8 timbers installed prior to fall, the a... |
| 09/22/2008 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | An unplanned fall was discovered on an exam app 6800fr from the #1 section. The fall measured 20' in length and 20' in width by 8' in height. |
| 09/15/2008 | ALL OTHER OCCUPATIONAL ILLNESSES | OCCUPATNAL ILLNESS NOT DEG 1-6 | 260d lost | EE was operating a scoop and stated he jarred himself and his back has started to hurt him. |
| 09/02/2008 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | A unplanned roof fall occurred on the #3 belt at break # 10. The fall measured app. 20' in width X 30' in length X 8' in height. It was bolted with 6' torque tension bolts. The area was dangered off.... |
| 08/30/2008 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | A unplanned roof fall was discovered at S.S.# 3162 to S.S.# 3192, the size of the fall measured approx. 140' in length X 18' in width X 8' high. The area was dangered off and timbers were set. This a... |
| 08/22/2008 | HANDLING OF MATERIALS | NO DYS AWY FRM WRK,NO RSTR ACT | None | The injured was taking down a piece of miner cable and when he got to the last hanger he dropped the cable and it caused the hanger to spring and caught the palm on his caused a laceration requiring s... |
| 07/31/2008 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | A unplanned roof fall occurred in the #1 entry 1 x-cut outby. The 001 section at 0500, the size was 18'Wx20'Lx14'H. At spad #3292 in the return. The state and MSHA were both notified at 0515. The fal... |
| 07/30/2008 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | Unplanned roof fall was discovered at in the intersection of the return airway at spad # 3018-# 3019. The area will not be rehabilited and does not effect the airway. It has been breakered off. The me... |
| 07/22/2008 | SLIP OR FALL OF PERSON | NO DYS AWY FRM WRK,NO RSTR ACT | None | Injured was unplugging a battery bell on a scoop and slipped, striking his elbow on the side of the frame, causing a laceration on his left elbow. Injured received 3 sutuchers. |
| 06/18/2008 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | Roof fall discovered 1100 ft in the #1 entry of #1 section spad #3067 in the return, measuring 90'L x 18'W x 7' thick. The fall was investigated by MSHA & WV OMSH&T. |
| 06/09/2008 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | Unplanned roof fall was discovered 3600' outby #001 section in #1 entry 2 breaks outby spad # 2740. The area will not be rehabed. The size was 80' L x 18' W x 8' H. It was bolted with 6' torque tensio... |
| 04/25/2008 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | Unplanned roof fall in the #1 entry on the 001 section measuring 160' in length X 18' in widthX8'-10' in height. The fall was immediatley reported and all entrences were breakered off. This area will... |
| 04/20/2008 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | An unplaned roof fall occured in the #4 entry app.2100 ft. from the working face. The size of the fall was 50' in lengthX 20' in width X 9' in height. The fall was inspected by MSHA and the WVOMHS&T.... |
| 03/29/2008 | HANDLING OF MATERIALS | NO DYS AWY FRM WRK,NO RSTR ACT | None | Member was attempting to put a load of rail in a switch when the coupler pin came out and the car broke the safety chain. The chain caught a piece of water line causing it to spring and hit him in the... |
| 03/20/2008 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | An unplanned fall measuring 100' in length X 18' in width X 9' in height, fell on the #2 section at approx 3:40 pm. This was immediatley reported and dangered off. Timbers were installed to block the... |
| 03/19/2008 | FALL OF ROOF OR BACK | DAYS AWAY FROM WORK ONLY | 71d lost | While loading coal in the #4 entry a rock fell, measuring 41"" long X 33"" wide X 10"", striking member on the head and right side of lower body. |
| 02/07/2008 | HANDLING OF MATERIALS | NO DYS AWY FRM WRK,NO RSTR ACT | None | EE was picking up a piece of structure and dropped it on his hand mashing his left ring finger. |
| 01/29/2008 | HANDLING OF MATERIALS | DAYS AWAY FROM WORK ONLY | 14d lost | Employee was walking and felt something in his left ankle pop. He stated he sprang his ankle while putting all his weight on it. |
| 01/28/2008 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | An unplanned roof fall was discovered at 9:45 a.m. on a routine airway exam in the #1 entry of the return entry at Spad Station # 1695. This is app.5,300 ft. from any section. Size of fall is 90ft. in... |
| 01/14/2008 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | An unplanned roof fall above anchorage of origianl 60"" fully grouted tourque tension roof bolts occured at this mine. The fall was app. 80' out-by the #1 entry. It measured 30 ft in length x 25 ft in... |
| 01/12/2008 | HANDTOOLS (NONPOWERED) | NO DYS AWY FRM WRK,NO RSTR ACT | None | Employee was cutting on a piece of control cable with a utility knife when it slipped off of the cable causing him to cut his wrist. He ceased work and received sutures as medical treament. |
| 12/08/2007 | HANDLING OF MATERIALS | DAYS AWAY FROM WORK ONLY | 127d lost | EE was stacking a stopping, when a block fell, striking him on the right leg. Caused a contusion to his right leg. EE was not determined as a lost time accident until Wednesday, 12/12/07. |
| 11/01/2007 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | There was a roof fall discovered 4000' out-by the section in the return entry. It is unknown of the time of occurrence. This area will not be rehabilitated. Has been dangered off and timbered off to p... |
| 10/29/2007 | HANDLING OF MATERIALS | DAYS AWAY FROM WORK ONLY | 38d lost | EE stated he was picking up an oxygen bottle and felt abdominal pain. |
| 10/06/2007 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | An unplanned roof fall at and above anchorage of original 48"" fully grouted roof bolts. Discoved in the return airway approx 5000' outby the #1 section. The area has been breakered off and dangered o... |
| 09/21/2007 | MACHINERY | NO DYS AWY FRM WRK,NO RSTR ACT | None | Employee's glove was caught between drill steel. When rotation was started it tore the glove away from his hand and dislocated his 5th left finger. |
| 08/22/2007 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | An unplanned roof fall at and above anchorage of original 48"" fully grouted roof bolts. The fall was discovered on a weekly exaim and was 15000 ft from any active workings. It was in neautral area of... |
| 07/11/2007 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | A roof fall was discovered in the #2 entry of the 001 section. The fall measured 40' in length x 20' in width x 6' in height. All entrances to fall are breakered off. The fall will not be rehabilitate... |
| 07/05/2007 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | Unplanned roof falls was discovered by preshift examiner on the 001-0 mmu. Falls were discovered in the #3 & #5 headings. Falls measured 20' w x 20'l x 6' h. 5' fully grouted resin bolts were being us... |
| 05/03/2007 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | A roof fall was discovered in the # 1 Entry of the 001 section return airway. The fall was located 2400 feet outby the section. It is app. 70' in length and 20' in width and app. 8' in height. The bol... |
| 03/29/2007 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | An unplanned roof fall occurred in the #4 face in the 4 right crosscut of the #2 section. Fall measured 20' x 20' x 7' high. Fall was on top of a Fletcher RRII roof bolting machine. No miners were aff... |