Saylor Mine — Accidents

Total: 8 accidents | Fatalities: 0

Date Classification Injury Days Lost Narrative
02/22/2011 FALL OF ROOF OR BACK ACCIDENT ONLY None Roof fall measuring 25' long, 20' wide, and 8' thick was discovered in the #4 entry at survey mark 66128 approximately 2000' from the working face. The area was developed 2/4/11 with 6' torque tensio...
02/15/2011 FALL OF ROOF OR BACK ACCIDENT ONLY None A roof fall measuring 20'long, 18'wide, and 8'thick was discovered in the #5 entry outby spad 66202. Fall was 600' from the working face and did not affect ventilation or the passage of men. Area wa...
02/14/2011 FALL OF ROOF OR BACK ACCIDENT ONLY None A roof fall measuring 36'long, 19'wide, and 12'thick was discovered in the #4 entry 6 belt inby spad 65935. The fall was 650' from the working section and was developed Jan 2011 with 6' and 8' torque...
02/03/2011 FALL OF ROOF OR BACK ACCIDENT ONLY None Roof fall was discovered in return 3200' from working face and measured 50' long, 18.5' wide, 12'thick. Fall was located in Southwest return panel and was developed in 2009, 4' glue bolts were the pr...
02/01/2011 FALL OF ROOF OR BACK ACCIDENT ONLY None Roof fall discovered in return 3900' from working section measuring 80'-150' long, 160' wide, and unknown thickness. Fall was located between #7 and #8 entry, the area was developed 1/20/09 with 4' g...
12/17/2010 HANDTOOLS (NONPOWERED) NO DYS AWY FRM WRK,NO RSTR ACT None While using sledge hammer to strike feeder drive chain, employee missed his target, striking finger on his left hand between feeder frame and hammer handle.
07/13/2010 FALL OF ROOF OR BACK ACCIDENT ONLY None A roof fall was discovered in the 3rd left return off #2 mains at spad 63665. The fall was 2000' outby the working section, neither ventilation nor the passage of men was not affected. The fall meas...
09/01/2009 FALL OF ROOF OR BACK PERM TOT OR PERM PRTL DISABLTY 43d lost Employee was reaching for a bundle of roof bolt plates while operating a roof bolter, when rock measuring 24"" x 18"" x 6"" thick fell from the roof between 2 previous roof supports and struck the rig...