Shoals Mine — Accidents

Total: 64 accidents | Fatalities: 0

Date Classification Injury Days Lost Narrative
05/02/2003 HOISTING ACCIDENT ONLY None A THUNDER AND LIGHTNING SWEPT THROUGH TOWN ON FRIDAY (5-2-03) A BOLT OF LIGHTNING STRUCK OUR PHONE LINES, IMPAIRING OUR PHONE SYSTEM. THE ABB COMPUTER SYSTEM IS CONNECTED TO THE PHONE LINE AND WHEN LI...
01/07/2003 HOISTING ACCIDENT ONLY None WE CONTRACTED ABB TO INSTALL A NEW HOIST CONTROLLER & SKIP LOADER PLC. DURING THEIR FINAL COMMISSIONING & PROGRAMMING PHASE A HOIST FAILURE OCCURRED, RESULTING IN THE CHUTE LOADER REMAINING IN THE OPE...
11/25/2002 HOISTING ACCIDENT ONLY None IN PREPARATION FOR A PLANNED HOIST RENOVATION INDECEMBER, THE PLANT ELECTRICIANS INSTALLED A SETOF NEW SHAFT SWITCHES. DUE TO UNEXPECTED SENSITIVITY OF THE SWITCHES THE LOADING SHAFT INADVERTE NTLY AC...
04/09/2002 SLIP OR FALL OF PERSON DAYS RESTRICTED ACTIVITY ONLY 2d restricted EE WAS WORKING ON #12 ATLAS DRILL. WORKING SURFACE OF DRILL WAS ELEVATED APPROX 40"" OFF GROUND. HE CLIMBED UP THE EQUIPMENT TO RETRIEVE A BATTERY CHARGER USING AN 8"" BLOCK OF WOOD AS A STEP LA DDER....
04/06/2002 EXPLODING VESSELS UNDER PRESSURE NO DYS AWY FRM WRK,NO RSTR ACT None EE WAS ON LIFT PLATFORM OF #17 ANFO LOADER. AS OPERATOR ENGAGED HYDRAULIC SYSTEM TO RAISE TABLE,EE TUMBLED BACKWARDS FALLING ON HIS BACK. A HYDRAULIC HOSE BLEW @ SAME TIME EE FELL, SPRAYING HI M W/OIL...
02/25/2002 HOISTING ACCIDENT ONLY None BECAUSE OF A RUSTED BRACKET, A SEMAN SWITCH FELL OFF OF THE TRACK AT THE BOTTOM OF THE SHAFT. THE SWITCH INDICATES THE STOPPING POSITION FOR THE EMERGENCY MAN CAGE.
10/16/2001 HANDLING OF MATERIALS NO DYS AWY FRM WRK,NO RSTR ACT None WHILE GETTING IN A DRILL TO DRILL A FACE, THE EMPLOYEE CLOSED THE DOOR ON HIS LEFT RING FINGER. NOT REALIZING HIS FINGER WAS IN THE DOOR HE TRIED TO PULL HIS FINGER OUT OF THE DOOR, CAUSING A LACERATI...
09/21/2001 HOISTING ACCIDENT ONLY None DURING ROUTINE INSPECTION OF THE EMERGENCY AIR SHAFT CONVEYANCE HOIST, IT WAS DISCOVERED THAT THE EMERGENCY BRAKE RELASE WITCH WAS OUT OF ADJUSTMENT AND ROPE SLACK DEVICE WAS TRIPPED, RENDERIN G THE H...
07/30/2001 HOISTING ACCIDENT ONLY None ELECTRICAL WIRE WENT TO GROUND CAUSING HOIST TO STOP OPERATING. PROBLEM WAS DIAGNOSED AND REPAIRED AND HOIST WAS BACK IN OPERATION IN 40 MINUTES.
03/07/2001 HOISTING ACCIDENT ONLY None A SWITCH AT THE BOTTOM OF ESCAPE SHAFT WAS FOUND TO BE FAULTY DURING ROUTINE INSPECTION.
01/08/2001 HOISTING ACCIDENT ONLY None HOIST ROPE SLACK SWITCH TENSION WAS OFF.
09/25/2000 HOISTING ACCIDENT ONLY None A POWER OUTAGE OCCURED UPON RE-ENGERIZING OF THEHOIST, IT WAS FOUND THAT A 800AMP MAIN FUSE & A 5AMP OUTPUT CORD FUSE FLEW RENDERING THE HOIST INOPERATIVE. THE HOIST WAS DOWN FOR 35 MINS
05/01/2000 HANDTOOLS (NONPOWERED) NO DYS AWY FRM WRK,NO RSTR ACT None EE WAS RODDING OUT #3 LAND PLASTER BIN. A LONG HEAVY ROD WITH A BEND AT THE END OF IT WAS USED TO DISLODGE HARDENED MATERIAL. WHILE RODDING ON THE BIN W/FORCE, PART OF THE MATERIAL GAVE WAY. T HE ROD...
03/13/2000 HOISTING ACCIDENT ONLY None LOOSE SODDER CONNECTION ON CIRCUIT BOARD ON MINE HOIST.