Total: 3 accidents | Fatalities: 0

Date Classification Injury Days Lost Narrative
02/05/2025 DISORDERS (REPEATED TRAUMA) OCCUPATNAL ILLNESS NOT DEG 1-6 None Code 26 - Moderate loss in hearing
06/14/2024 ELECTRICAL DAYS AWAY FROM WORK ONLY 15d lost Electrical Contractor was wiring drive for water pump when Arc Flash occurred. Contractor was working alone and doesn't remember what could have caused accident. Contractor suffered burns to arms.
08/02/2018 HANDTOOLS (NONPOWERED) DAYS RESTRICTED ACTIVITY ONLY 1d restricted Employee was using a 3/4"" ratchet & socket to tighten a conveyor belt at the tail pulley. The ratchet slipped off causing the employee to fall forward hitting head/eye on guarding framework.