Whitetail Kittanning Mine — Accidents
Total: 782 accidents | Fatalities: 1
| Date | Classification | Injury | Days Lost | Narrative |
|---|---|---|---|---|
| 11/19/2003 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | EAST 1 RIGHT, BLOCK 15 ENTRY 8 4-WAY MMU 008, WORKED OUT AREA. 20 FT LONG X 20 FT WIDE X 10 FT HIGH. TYPE OF SUPPORT: CABLE BOLTS, 6 FT 3/4 INCH RESIN, ROOF MATS. FALL DANGERED OFF, ADDITIONAL ROOF SU... |
| 11/19/2003 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | EAST 1 RIGHT, BLOCK 12 ENTRY 8 4-WAY MMU 008, WORKED OUT AREA. 20 FT LONG X 20 FT WIDE X 10 FT HIGH. TYPE OF SUPPORT: CABLE BOLTS, 6 FT 3/4 INCH RESIN, ROOF MATS. FALL DANGERED OFF, ADDITIONAL ROOF SU... |
| 11/19/2003 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | EAST 1 RIGHT, BLOCK 6 ENTRY 10 4-WAY, MMU 007, WORKED OUT AREA. 20 FT LONG X 20 FT WIDE X 10 FT HIGH. TYPE OF SUPPORT: CABLE BOLTS, 6 FT 3/4 INCH RESIN, ROOF MATS. FALL DANGERED OFF, ADDITIONA L ROOF... |
| 11/19/2003 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | EAST 1 RIGHT, BLOCK 7 ENTRY 11 3-WAY, MMU 007, WORKED OUT AREA. 20 FT LONG X 18 FT WIDE X 10 FT HIGH. TYPE OF SUPPORT: CABLE BOLTS, 6 FT 3/4 INCH RESIN, ROOF MATS. FALL DANGERED OFF, ADDITIONA L ROOF... |
| 11/19/2003 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | EAST 1 RIGHT, BLOCK 17 TO 18 ENTRY 4 4-WAY & ENTRY, MMU 007, WORKED OUT AREA. 50 FT LONG X 18 FT WIDE X 10 FT HIGH. TYPE OF SUPPORT: CABLE BOLTS, 6 FT 3/4 INCH RESIN, ROOF MATS. FALL DANGERED OFF, ADD... |
| 11/19/2003 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | EAST 1 RIGHT, BLOCK 14 ENTRY 4 4-WAY MMU 007, WORKED OUT AREA. 20 FT LONG X 20 FT WIDE X 10 FT HIGH. TYPE OF SUPPORT: CABLE BOLTS, 6 FT 3/4 INCH RESIN, ROOF MATS. FALL DANGERED OFF, ADDITIONAL ROOF SU... |
| 11/05/2003 | SLIP OR FALL OF PERSON | DAYS AWAY FROM WORK ONLY | 17d lost | WEST 2 BELT: EMPLOYEE WAS WALKING ALONG THE BELT WITH HIS DINNER BUCKET IN HAND. IN THE AREA OF THE ACCIDENT HE WAS WALKING ON THE 8-INCH WATER LINE AND SLIPPED AND FELL AGAINST AN ACS JACK. T HE X-RA... |
| 11/04/2003 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | EAST 3 BLOCK, #3 ENTRY MMU 007 65 FT LONG BY 17 FT WIDE BY 16 FT HIGH. TYPE OF SUPPORT: CABLE BOLTS 6 FT 3/4 IN RESIN BOLTS, ROOF MATS. FALL DANGERED OFF, ADDITIONAL ROOF SUPPORTS SET AROUND F ALL. |
| 11/04/2003 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | EAST 1 RIGHT, 6 TO 7 BLOCK, 7 ENTRY, WORKED OUT AREA. 17 FT LONG X 20 FT WIDE X 7 FT HIGH. TYPE OF SUPPORT: 6 FT 3/4 INCH RESIN, ROOF MATS , SCREEN. FALL DANGERED OFF, ADDITIONAL ROOF SUPPORTS SET ARO... |
| 11/04/2003 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | EAST 1 RIGHT, 5 BLOCK, 3 ENTRY, WORKED OUT AREA, 3-WAY. 20 FT LONG X 20 FT WIDE X 8 FT HIGH. TYPE OF SUPPORT: CABLE BOLTS, 6 FT 3/4 INCH RES IN, ROOF MATS, SCREEN. FALL DANGERED OFF, ADDITIONAL ROOF S... |
| 11/04/2003 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | EAST 1 RIGHT, 12 BLOCK, 3 ENTRY, WORKED OUT AREA, 4-WAY. 17 FT LONG X 15 FT WIDE X 10 FT HIGH. TYPE OF SUPPORT: CABLE BOLTS, 6 FT 3/4 INCH RES IN, ROOF MATS. FALL DANGERED OFF, ADDITIONAL ROOF SUPPORT... |
| 11/04/2003 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | EAST 3, BLOCK 62, #2 ENTRY, MMU 007 50 FT LONG BY 17 FT WIDE BY 10 FT HIGH. TYPE OF SUPPORT 6 FT3/4 IN RESIN BOLTS, ROOF MATS. FALL DANGERED OFF, ADDITIONAL ROOF SUPPORTS SET AROUND FALL. |
| 11/04/2003 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | EAST 1 RIGHT, 10 BLOCK, 4 ENTRY, WORKED OUT AREA, 4-WAY. 70 FT LONG X 17 FT WIDE X 10 FT HIGH. TYPE OF SUPPORT: CABLE BOLTS, 6 FT 3/4 INCH RES IN, ROOF MATS, SCREEN. FALL DANGERED OFF, ADDITIONAL ROOF... |
| 11/04/2003 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | EAST 1 RIGHT, 8 BLOCK, 6 ENTRY, WORKED OUT AREA, 4-WAY. 17 FT LONG X 30 FT WIDE X 10 FT HIGH. TYPE OF SUPPORT: CABLE BOLTS, 6 FT 3/4 INCH RES IN, ROOF MATS, SCREEN. FALL DANGERED OFF, ADDITIONAL ROOF... |
| 11/04/2003 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | EAST 1 RIGHT, 11 BLOCK, 7 ENTRY, WORKED OUT AREA, 4-WAY. 20 FT LONG X 20 FT WIDE X 10 FT HIGH. TYPE OF SUPPORT: CABLE BOLTS, 6 FT 3/4 INCH RES IN, ROOF MATS, SCREEN. FALL DANGERED OFF, ADDITIONAL ROOF... |
| 11/04/2003 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | EAST 1 RIGHT, 12 TO 13 BLOCK, 5 ENTRY, WORKED OUT AREA, ENTRY. 50 FT LONG X 17 FT WIDE X 8 FT HIGH. TYPE OF SUPPORT: 6 FT 3/4 INCH RESIN, ROOF MATS , SCREEN. FALL DANGERED OFF, ADDITIONAL ROOF SUPPORT... |
| 11/04/2003 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | EAST 2 RIGHT, 6 BLOCK, 7 ENTRY, WORK OUT AREA, 2-WAY. 17 FT LONG X 40 FT WIDE X 8 FT HIGH. TYPE OF SUPPORT: CABLE BOLTS, 6 FT 3/4 INCH RES IN, ROOF MATS, SCREEN. FALL DANGERED OFF, ADDITIONAL ROOF SUP... |
| 11/04/2003 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | EAST 1 RIGHT, 5 BLOCK, 7 ENTRY, WORKED OUT AREA, 3-WAY. 17 FT LONG X 50 FT WIDE X 8 FT HIGH. TYPE OF SUPPORT: CABLE BOLTS, 6 FT 3/4 INCH RES IN, ROOF MATS, SCREEN. FALL DANGERED OFF, ADDITIONAL ROOF S... |
| 11/04/2003 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | EAST 4, BLOCK 7, #3 ENTRY, 4 WAY INTERSECTION, MMU 007 17 FT LONG BY 40 FT WIDE BY 16 FT HIGH. TYPE OF SUPPORT, CABLE BOLTS, 6 FT 3/4 RESIN BOLTS, ROOF MATS. FALL DANGERED OFF, ADDITIONAL ROO F SUPPOR... |
| 11/04/2003 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | EAST 2 RIGHT, 14 BLOCK, 8 ENTRY, WORK OUT AREA, 4-WAY. 18 FT LONG X 18 FT WIDE X 10 FT HIGH. TYPE OF SUPPORT: CABLE BOLTS, 6 FT 3/4 INCH RES IN, ROOF MATS, SCREEN. FALL DANGERED OFF, ADDITIONAL ROOF S... |
| 11/04/2003 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | EAST 1 RIGHT, 13 BLOCK, 2 ENTRY, WORKED OUT AREA, 4-WAY. 20 FT LONG X 20 FT WIDE X 10 FT HIGH. TYPE OF SUPPORT: CABLE BOLTS, 6 FT 3/4 INCH RES IN, ROOF MATS. FALL DANGERED OFF, ADDITIONAL ROOF SUPPORT... |
| 10/26/2003 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | EAST 5, 18 BLOCK, #7 ENTRY, MMU 008, 4-WAY INTERSECTION. 20 FT LONG X 20 FT WIDE X 7 FT WIDE. TYPE OF SUPPORT: CABLE BOLTS, 6 FT 3/4 INCH RESIN BOLTS, ROOF MATS, WIRE SCREEN. FALL DANGERE D OFF, ADDIT... |
| 10/26/2003 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | EAST 3, 49 BLOCK, #6 ENTRY, MMU 008, 4-WAY INTERSECTION. 15 FT LONG X 20 FT WIDE X 7 FT WIDE. TYPE OF SUPPORT: 12 CABLE BOLTS, 6 FT 3/4 INCH RESIN BOLTS, ROOF MATS WIRE SCREEN. FALL DANGERE D OFF, ADD... |
| 10/24/2003 | MACHINERY | DAYS AWAY FROM WORK ONLY | 7d lost | THE EE WAS DRILLING IN SANDSTONE AND THE STEEL BENT. WHEN HE TRIED TO BRING THE BENT STEEL DOWN, HE ACCIDENTLY HIT THE ROTATE WITH THE JOY STICK. THE STEEL WHIPPED AND STRUCK HIS HEAD AND LEFT PORTION... |
| 10/23/2003 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | EAST 5, 13 BLOCK, #5 ENTRY, MMU 005, 4-WAY INTERSECTION. 20 FT LONG X 15 FT WIDE X 8 FT HIGH. TYPE OF SUPPORT: CABLE BOLTS, 6 FT 3/4 INCH RESIN, ROOF MATS, WIRE SCREEN. FALL DANGERED OFF, ADDITIONAL R... |
| 10/20/2003 | HANDLING OF MATERIALS | DAYS AWAY FROM WORK ONLY | 54d lost | MECHANIC/ELECTRICAN: THE EE WAS CHANGING THE CHAIN ON A SHUTTLE CAR REEL AND THE COVER FELL AND STRUCK HIS RIGHT FOOT. THE EX-RAY WAS NEGATIVE BRUISE TO FOOT HOWEVER THE EE DID NOT RETURN TO W ORK HIS... |
| 10/18/2003 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | EAST 3, 41 BLOCK, #6 ENTRY, MMU 008, 4-WAY INTERSECTION. 20 FT LONG X 20 FT WIDE X 7 FT WIDE. TYPE OF SUPPORT: 6 FT 3/4 INCH RESIN, CABLE BOLTS, ROOF MATS, WIRE SCREEN. HEINTZMANN & BARS. FA LL DANGER... |
| 10/16/2003 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | SOUTH 3, #5 ENTRY, BETWEEN #19 & 20 BLOCK. SPAD OUTBY 5573, MMU 005. 30'LONG, 17'WIDE X 8'HIGH. TYPE OF SUPPORT: 6 FT 3/4 INCH RESIN BOLTS, 6 IN X 16 IN PLATES, ROOF MATS, WIRE SCREEN. FALL DANGERED O... |
| 10/08/2003 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | SOUTH 3, #4 HEADING, BETWEEN 11 & 12 BLOCK, MMU 005 SPAD 5446. 25 FT LONG X 12 FT WIDE X 7 FT HIGH. TYPE OF SUPPORT: 6' 3/4"" RESING - 6 IN X 6 IN PLATES, ROOF MATS. FALL DANGERED OFF, ADDITIO NAL ROO... |
| 10/08/2003 | DUST DISEASE OF LUNGS | OCCUPATNAL ILLNESS NOT DEG 1-6 | None | PROLONGED EXPOSURE TO COAL DUST, MEDICAL EXAMINATION INDICATES THAT THIS MINER HAS A SUFFICIENT DEGREE OF PNEUMOCONIOSIS. |
| 10/08/2003 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | SOUTH 3, #4 HEADING, BETWEEN 13 & 14 BLOCK, MMU 005 SPAD 5462. 25 FT LONG X 12 FT WIDE X 7 FT HIGH. TYPE OF SUPPORT: 6' 3/4"" RESING - 6 IN X 6 IN PLATES, ROOF MATS. FALL DANGERED OFF, ADDITIO NAL ROO... |
| 10/08/2003 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | SOUTH 3, #7 BLOCK, CROSSCUT 4 TO 5 HEADING, MMU 005 SPAD 5406. 25 FT LONG X 17 FT WIDE X 7 FT HIGH. TYPE OF SUPPERT: 6 FT 3/4 RESING - 6 IN X 6 IN PLATES, ROOF MATS. FALL DANGERED OFF, ADDITIO NAL ROO... |
| 10/07/2003 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | SOUTH 3, 3ENTRY-INBY 4-WAY AT 21 BLOCK INCLUDING 4-WAY AT 22 BLOCK. 80 FT LONG X 18 FT WIDE X 10 FT HIGH. TYPE OF SUPPORT: 6 FT 3/4 IN RESING, 8 X 8 IN PLATES, ROOF MATS, 12 FT CABLE IN 4-WAY. ACS JAC... |
| 10/06/2003 | MACHINERY | DAYS AWAY FROM WORK ONLY | 10d lost | THE EMPLOYEE WAS PREPARING TO INSTALL THE LAST ROW OF BOLTS IN THE CUT. THE ATR JACKS WERE SET AND THE EMPLOYEE STATED THAT THE TOP WAS CHECKED (VISUAL & SOUND). WHEN HE TURNED AWAY FROM THE F ACE, A... |
| 10/03/2003 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | NORTH MAINS, 16 BLOCK, X-CUT 8-9, MMU 002. 15' LONG X 15'WIDE X 8'HIGH. TYPE OF SUPPORT: 6'RESIN 3/4"", 8""X 16""PLATES, ROOF MATS, SCREEN. FALL DANGERED OFF, CLEAN-UP PLAN DEVELOPED & POSTED, ADDITIO... |
| 10/02/2003 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | EAST 2, 21 BLOCK, X-CUT 4-5, MMU 007. 10'LONG X 12'WIDE X 6'HIGH. TYPE OF SUPPORT: 6'RESIN 3/4"" , 8""X 8""PLATES, ROOF MATS, SCREEN. FALL DANGERED OFF, ADDITIONAL SUPPORTS SET AROUND FALL. |
| 09/29/2003 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | EAST 2 RIGHT #8 HDG 10 TO 11 BLOCK AND 11 INTERSECTION MMU 008 80FT LONG X 18FT WIDE X 7FT HIGHTYPE OF SUPPORT: 6FT 3/4"" RESIN BOLTS 8"" X8"" PLATES, SCREEN IN INTERSECTION FALL SUPPORT SIT AROUND FA... |
| 09/29/2003 | SLIP OR FALL OF PERSON | DAYS AWAY FROM WORK ONLY | 19d lost | THE EE WAS LOADING SUPPLIES ON ROOF BOLT MACHINE. EE WAS CARRYING A BUNDLE OF PLATES& TRIPPED ONTHE BOLTER CABLE. BEFORE HE FELL HE TOSSED THE PLATES AWAY FROM HIS BODY. HE LANDED ON HIS W-65 THAT WAS... |
| 09/27/2003 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | SOUTH MAINS 71 BLOCK #7HEADING 4-WAY MMU 006 35FT LONG X 20FT WIDE 12FT HIGH TYPE OF SUPPORT:CABLE BOLTS, 6FT 3/4 RESIN BOLTS, SCREEN, HEINTZMANN, JACKS & BARS. FALL DANGERED OFF ADDITONAL ROOF SUPPOR... |
| 09/26/2003 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | SOUTH 3, 25 BLOCK, #2 HEADING, 4-WAY, MMU 005. 25'LONG X 18'WIDE X 10'HIGH. TYPE OF SUPPORTS: 12' CABLE BOLTS, 6'RESIN 3/4"", 8""X 8"" PLATES, ROOF MATS. FALL DANGERED OFF, ADDITIONAL ROOF SUPPORTS SE... |
| 09/26/2003 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | 18' LONG X 18'WIDE X 7'HIGH. SOUTH 4, O HEADING,6 BLOCK, 3-WAY, MMU 005. TYPE OF SUPPORT: 12'CABLE, 6'RESIN 3/4"", 8""X 8"" PLATES, ROOF MATS. FALL DANGERED OFF, ADDITIONAL ROOF SUPPORT SET AROUND FAL... |
| 09/26/2003 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | SOUTH 4, 2 HEADING, #8 BLOCK, 4-WAY, MMU 005. 20'LONG X 18'WIDE X 8'HIGH. TYPE OF SUPPORT: 12'CABLE, 6' 3/4""RESIN - 8""X 8"" PLATES, ROOF MATS. DANGERED OFF, ADDITIONAL ROOF SUPPORTS SET AROUN D FALL... |
| 09/24/2003 | STEPPING OR KNEELING ON OBJECT | DAYS AWAY FROM WORK ONLY | 20d lost | THE EE WAS WALKING DOWN THE ENTRY AND STEPPED ON A ROCK AND TWISTED HIS RIGHT KNEE. THE PHYSCION RECOMMENDED ICE, REST AND POSSIBLE THEAPY 9-26-03 THE EE FIRST DAY AWAY FROM WORK WAS 9-26-03 |
| 09/22/2003 | SLIP OR FALL OF PERSON | DAYS AWAY FROM WORK ONLY | 4d lost | THE EE RODE TO THE SECTION IN A RAIL MAN BUS ANDWHEN HE GOT OUT OF THE CAR, TWISTED HIS BACK. |
| 09/17/2003 | DUST DISEASE OF LUNGS | OCCUPATNAL ILLNESS NOT DEG 1-6 | None | PROLONGED EXPOSURE TO COAL DUST, MEDICAL EXAMINATION INDICATES THAT THIS MINER HAS A SUFFICIENT DEGREE OF PNEUMOCONIOSIS. |
| 09/12/2003 | DUST DISEASE OF LUNGS | OCCUPATNAL ILLNESS NOT DEG 1-6 | None | PROLONGED EXPOSURE TO COAL DUST, MEDICAL EXAMINATION INDICATES THAT THIS MINER HAS A SUFFICIENT DEGREE OF PNEUMOCONIOSIS. |
| 09/05/2003 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | NORTH 3 #4HEADING 9 TO 10 BLOCK-ENTRY MMU 003. 60 FT LONG X 17 FT WIDE X 7 FT HIGH. TYPE OF SUPPORT: 6 FT 3/4"" RESIN-8"" X 8"" PLATES, ROOF MATS. FALL DANGERED OFF, ADDITIONAL ROOF SUPPORTS SET AROUN... |
| 09/04/2003 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | EAST 1, 4 BLOCK, #5 & #6 CROSS-CUT MMU 007. 17 FT WIDE X 40 FT LONG X 7 FT HIGH. TYPE OF SUPPORT: CABLE BOLTS-8"" X 8"" PLATES, 6 FT RESIN 3/4""-6"" X 6"" PLATES, ROOF MATS. FALL DANGERED OFF, ADDI TI... |
| 09/02/2003 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | EAST 4 7 BLOCK #8 HEADING 4-WAY MMU 008. 20 FT WIDE X 20 FT LONG X 12 FT HIGH. TYPE OF SUPPORTS: CABLE BOLTS-8"" X 8"" PLATES, 6 FT RESIN 3/4""-8"" X 8"" PLATES, ROOF MATS TRUSS BOLTS. FALL DANGERE D... |
| 09/01/2003 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | WEST 2 14 BLOCK #4 INTERSECTION X-CUT #4 TO #5 & #5 INTERSECTION MMU 001. TYPE OF SUPPORT: CABLE BOLTS-INTERSECTIONS. 6 FT RESIN-3/4"" WITH 8""X8"" PLATES. ROOF MATS, SCREEN IN #5 INTERSECTION. 1 00 F... |