Cargill Deicing Technology-Cleveland Mn — Accidents
Total: 357 accidents | Fatalities: 1
| Date | Classification | Injury | Days Lost | Narrative |
|---|---|---|---|---|
| 02/11/2026 | HOISTING | ACCIDENT ONLY | None | PHoist did not pass pinion brake checks. A mechanic was called to adjust, and upon inspection, it was found that an electrical contact in the pinion brake caliper had corroded and was broken. An evac... |
| 10/06/2025 | MACHINERY | DAYS AWAY FROM WORK ONLY | None | Two employees were bolting in a narrow belt line area when the bolter tripped the e-stop cable. While discussing reset options, one employee attempted to squeeze through a tight area. While doing so,... |
| 09/12/2025 | HOISTING | ACCIDENT ONLY | None | Lost power to the mine due to an outage from Cleveland Public Power (CPP). Reported issue to CPP |
| 09/01/2025 | HOISTING | ACCIDENT ONLY | None | Faults were occurring on Phoist that could not be cleared at approximately 11:35 pm. EVAC was called at approximately 12:05 am since we were still troubleshooting the issue and did not have control of... |
| 08/11/2025 | HOISTING | ACCIDENT ONLY | None | Loss of power due to transformer issue at neighboring business. Notified Cleveland Public Power (CPP) of issue. |
| 07/29/2025 | HOISTING | ACCIDENT ONLY | None | Loss of power on surface and underground due to city outage. Reported to Cleveland Public Power (CPP) for repair. |
| 07/24/2025 | HOISTING | ACCIDENT ONLY | None | Power failure due to loss of incoming power from city substation. Notified Cleveland Public Power to report outage. |
| 06/28/2025 | FIRE | ACCIDENT ONLY | None | An employee observed an electrician's golf cart that was parked near the Phoist control room was on fire and notified their supervisor. The supervisor contacted CFD and verified that the EVAC system w... |
| 06/19/2025 | HOISTING | ACCIDENT ONLY | None | Lost operation of the PHoist due to a failed drive module |
| 06/19/2025 | HOISTING | ACCIDENT ONLY | None | Lost use of PHoist due to drive fault/bad module caused by high moisture. |
| 06/15/2025 | MACHINERY | ACCIDENT ONLY | None | At approximately 10:30 PM, the number one main fan went down due to mechanical issues. Based on the inspection, it appears the impellers came off, the bearing locked up and it went high amps/temp. |
| 05/27/2025 | HOISTING | ACCIDENT ONLY | None | During hoist checks, the tanks for the pneumatic system did not refill. Issue could not be resolved within allotted time frame, so EVAC was called. Cause of issue was found to be a rubber gasket from... |
| 05/02/2025 | HANDTOOLS (NONPOWERED) | DAYS RESTRICTED ACTIVITY ONLY | 1d restricted | An employee was cutting a zip tie off of a D-ring when the knife slipped and sliced the inside of EE's left forearm. The laceration was approximately 1"" in length and required 3 stitches. The employe... |
| 03/25/2025 | SLIP OR FALL OF PERSON | DAYS RESTRICTED ACTIVITY ONLY | 4d restricted | Surface employee tripped/fell near rail yard and suffered minor abrasions/contusions to left hand, right knee/thigh & right chest. Medical attention was offered and declined. 3 days later (3/28/25), e... |
| 02/22/2025 | HOISTING | ACCIDENT ONLY | None | Lost drive module on Phoist. |
| 01/09/2025 | HOISTING | ACCIDENT ONLY | None | Transformer blew on surface, which caused power to drop on the surface and in the mine. Outage was reported to Cleveland Public Power (CPP) and mine was evacuated until power was restored. |
| 12/09/2024 | HOISTING | ACCIDENT ONLY | None | Lost power to the site. Issue was related to Cleveland Public Power (CPP). Issue was being worked on and resolved by CPP. |
| 11/27/2024 | POWERED HAULAGE | FATALITY | Fatal | A loader bucket on a CAT R3000H came down and crushed an employee while in use, resulting in a fatality. The injured employee was operating a UTV (gator) in Unit 43 near the feeder breaker (Stamler) w... |
| 10/30/2024 | HOISTING | ACCIDENT ONLY | None | Lost use of the Phoist. Troubleshooting found that there was a bad drive/fuse that needed to be replaced. Called evacuation while repairs were being made |
| 10/17/2024 | HOISTING | ACCIDENT ONLY | None | PHoist brake not functioning properly. Brake switch needed to be adjusted |
| 09/25/2024 | HOISTING | ACCIDENT ONLY | None | Mine EVAC was called due to liner issues on SHoist |
| 08/16/2024 | HOISTING | ACCIDENT ONLY | None | Power outage dropped power on surface and in mine, no power to Phoist. |
| 08/06/2024 | HOISTING | ACCIDENT ONLY | None | Inclement weather caused mine and part of surface operations to drop power. Generators were utilized and a mine evac was called. |
| 07/09/2024 | HANDTOOLS (NONPOWERED) | NO DYS AWY FRM WRK,NO RSTR ACT | None | Chipping concrete and a piece of concrete dropped and rolled towards employee cutting EE's leg. |
| 07/01/2024 | HANDLING OF MATERIALS | NO DYS AWY FRM WRK,NO RSTR ACT | None | Employee was working to repair an emergency lowering and jammed EE's finger while removing the guard. EE reported but declined medical attention. Employee reported swelling and discomfort 8 days later... |
| 05/13/2024 | HANDLING OF MATERIALS | DYS AWY FRM WRK & RESTRCTD ACT | 165d lost, 182d restricted | Employee shoveling and their shovel struck the cardboard/rocks surrounding, causing the shovel to stop abruptly. Employee felt a sharp pain in right shoulder and informed supervisor. Medical was offer... |
| 05/03/2024 | HOISTING | ACCIDENT ONLY | None | Ground fault on PHoist, SVI or SVE fault codes |
| 04/18/2024 | HOISTING | ACCIDENT ONLY | None | SHoist fault, believed to be an electrical issue with a sensor but we are trouble shooting to identify and repair. |
| 03/27/2024 | HANDLING OF MATERIALS | DAYS RESTRICTED ACTIVITY ONLY | 16d restricted | Employee was working on 1928 screw replacement. EE was pulling on the screw & felt pain in left shoulder. The employee was offered and declined medical attention. On 4/16/24 the employee stated that t... |
| 02/27/2024 | HANDLING OF MATERIALS | DYS AWY FRM WRK & RESTRCTD ACT | 7d lost, 133d restricted | EE was shoveling salt onto the belt while cleaning 22 skip tail. While raising the shovel to dump the salt onto the belt, the EE felt a sharp pain in their right shoulder/arm. EE noticed a large bruis... |
| 02/21/2024 | HOISTING | ACCIDENT ONLY | None | SHoist tripped out and could not be reset. |
| 01/24/2024 | INUNDATION | ACCIDENT ONLY | None | Drilling in unit 41, employee hit a methane bleeder. Initial readings were above permitted range, so a mine evacuation was called. |
| 01/16/2024 | OTHER | DAYS AWAY FROM WORK ONLY | 362d lost | An electrician reported pain in their right knee while walking up and down stairs. The employee declined medical attention. The employee later reported that the knee was feeling worse, so we took them... |
| 12/14/2023 | HANDLING OF MATERIALS | DAYS RESTRICTED ACTIVITY ONLY | 10d restricted | EE was lifting a steel bar attempting to load it into a roll of belt. During this process, the EE strained their left shoulder. |
| 12/07/2023 | HANDLING OF MATERIALS | NO DYS AWY FRM WRK,NO RSTR ACT | None | EE suffered 1st degree burn on right arm while checking coolant on piece of equipment. |
| 11/22/2023 | HOISTING | ACCIDENT ONLY | None | Damaged brake line on P hoist making it inoperable until repaired. |
| 11/20/2023 | HOISTING | ACCIDENT ONLY | None | P Hoist was not operable due to a blown hydraulic line. |
| 11/20/2023 | HOISTING | ACCIDENT ONLY | None | Actuator mount on SHoist was loose, so maintenance tightened it up. When doing so, it threw the position sensor off. An electrician attempted to adjust the switch and the connection broke off making i... |
| 11/15/2023 | HOISTING | ACCIDENT ONLY | None | PHoist had an alarm and would not function in auto or manual - South SPV1 pressure valve alarm would not reset. |
| 10/13/2023 | HOISTING | ACCIDENT ONLY | None | VFD module on PHoist |
| 10/06/2023 | HOISTING | ACCIDENT ONLY | None | Cleveland Public Power outage caused skip mine to drop power |
| 09/24/2023 | HOISTING | ACCIDENT ONLY | None | Programming error on P hoist |
| 09/22/2023 | HOISTING | ACCIDENT ONLY | None | Service hoist down, MG set will not start. |
| 09/06/2023 | HOISTING | ACCIDENT ONLY | None | Track limit switch failure on the PHoist |
| 07/22/2023 | HOISTING | ACCIDENT ONLY | None | Drive fault on P-hoist |
| 07/19/2023 | HOISTING | ACCIDENT ONLY | None | Overtravel of SHoist, unable to correct in manual. |
| 07/16/2023 | HOISTING | ACCIDENT ONLY | None | Production hoist was down due to blown drive module. |
| 07/16/2023 | HANDLING OF MATERIALS | DAYS RESTRICTED ACTIVITY ONLY | 29d restricted | One of the hoist ABB drives was overheating needed to be replaced. While installing the new drive, the drive rocked back, pulling hard on the EE's left shoulder and striking EE's shin. The employee su... |
| 06/30/2023 | HOISTING | ACCIDENT ONLY | None | Production Hoist fault |
| 05/30/2023 | HOISTING | ACCIDENT ONLY | None | Loss of power feed from the utility company, Cleveland Public Power (CPP), that provides power to hoist. |