Morton Salt Fairport Mine — Accidents
Total: 312 accidents | Fatalities: 0
| Date | Classification | Injury | Days Lost | Narrative |
|---|---|---|---|---|
| 02/05/2026 | HOISTING | ACCIDENT ONLY | None | Electrical contactor failed causing the production hoist to be unavailable for operation. |
| 01/30/2026 | HOISTING | ACCIDENT ONLY | None | Utility power outage caused hoist to be unavailable. |
| 01/24/2026 | HOISTING | ACCIDENT ONLY | None | Inspection mode switch faulty causing the production hoist to be unavailable. |
| 11/14/2025 | OTHER | INJURIES DUE TO NATURAL CAUSES | None | Office cleaning contractor sat in their truck to take a break and was found approximately one hour later deceased. Originally, a report was submitted to MSHA on 11/20/2025. |
| 11/11/2025 | HANDLING OF MATERIALS | DAYS AWAY FROM WORK ONLY | 1d lost | While erecting the C-3 take-up structure two employees were holding up an 8'x 8' column to have 2 bolts installed by another employee on the ground when they lost their hold on the column. It fell ove... |
| 11/03/2025 | POWERED HAULAGE | DYS AWY FRM WRK & RESTRCTD ACT | 40d lost, 28d restricted | Employee reported neck pain while using an LHD to clean up faces for drills and augers. Upon evaluation, the employee was diagnosed with a fracture. Work relatedness determination was made on 12/29/20... |
| 10/23/2025 | HOISTING | ACCIDENT ONLY | None | Electrical contactor failed causing the production hoist to be unavailable for operation. |
| 09/30/2025 | HOISTING | ACCIDENT ONLY | None | Nopak valve for south gate failed causing the production hoist to be unavailable. |
| 07/16/2025 | HOISTING | ACCIDENT ONLY | None | Work deck contacting brackets causing the production hoist to be inoperable. |
| 07/15/2025 | HOISTING | ACCIDENT ONLY | None | Material came loose from the North liner. Shutdown hoist to inspect shaft. |
| 06/30/2025 | HOISTING | ACCIDENT ONLY | None | The dynamic brakes faulted out causing the production hoist to be inoperable. Found switch in hoist operators booth in automatic. |
| 06/07/2025 | HOISTING | ACCIDENT ONLY | None | Production skip components failed causing the hoist to be unavailable for egress. |
| 05/31/2025 | HOISTING | ACCIDENT ONLY | None | Electrical contactor failed on the production hoist causing the hoist to be inoperable. |
| 05/27/2025 | HOISTING | ACCIDENT ONLY | None | The over travel switch malfunctioned causing the service hoist to be unavailable. EVAC was canceled. |
| 04/04/2025 | HOISTING | ACCIDENT ONLY | None | Koepe lower cage position switch and cable shorted causing the Koepe to be inoperable. |
| 03/06/2025 | HOISTING | ACCIDENT ONLY | None | Blown fuse caused the production hoist to be inoperable. |
| 11/21/2024 | HOISTING | ACCIDENT ONLY | None | Power outage from storm causing hoist to be unavailable. |
| 10/14/2024 | FIRE | ACCIDENT ONLY | None | A small fire occurred inside the compressor housing on AL2 powder rig. The fire was able to be extinguished at the time it occurred. |
| 10/13/2024 | HOISTING | ACCIDENT ONLY | None | Shaft crew identified a gap between the Capel and skip attachment plates. |
| 10/10/2024 | HOISTING | ACCIDENT ONLY | None | During a routine inspection, the shaft crew found three broken wires on the North rope. |
| 09/25/2024 | HOISTING | ACCIDENT ONLY | None | Lost power from our electricity provider causing the production hoist to be unavailable. Evacuation canceled. |
| 05/09/2024 | HOISTING | ACCIDENT ONLY | None | Lost power to a PLC on production hoist causing the production hoist to be inoperable. |
| 02/28/2024 | HOISTING | ACCIDENT ONLY | None | Lost primary power to the site causing the production hoist to be inoperable. Initiated EVAC. During the EVAC the Koepe faulted for Lilly differential. |
| 12/14/2023 | HOISTING | ACCIDENT ONLY | None | Failed electrical contactor on the production hoist. |
| 07/26/2023 | HOISTING | ACCIDENT ONLY | None | Lower cage position switch cable damaged. |
| 06/30/2023 | HOISTING | ACCIDENT ONLY | None | Safety circuit on the production hoist tripped and wouldn't reset. |
| 06/27/2023 | HOISTING | ACCIDENT ONLY | None | Identified damaged cross timber in the service shaft during weekly inspection. |
| 06/21/2023 | HOISTING | ACCIDENT ONLY | None | Replaced East hoist motor. Tested hoist operations and test runs conducted. |
| 06/16/2023 | HOISTING | ACCIDENT ONLY | None | North skip pocket was stuck in the open position. Evacuation canceled at 7:15am. |
| 06/02/2023 | HOISTING | ACCIDENT ONLY | None | Koepe wheel bracket became displaced of the top of the cage. |
| 04/24/2023 | HOISTING | ACCIDENT ONLY | None | North track limit switch failed. |
| 03/31/2023 | HOISTING | ACCIDENT ONLY | None | Broken wires on the rope of the production hoist. |
| 03/17/2023 | HOISTING | ACCIDENT ONLY | None | The south skip of the production hoist came out of the dump scroll on the south side and bent the lower gate. |
| 01/05/2023 | HOISTING | ACCIDENT ONLY | None | Production hoist outage. |
| 01/04/2023 | HOISTING | ACCIDENT ONLY | None | Production hoist outage. |
| 01/04/2023 | HOISTING | ACCIDENT ONLY | None | Production hoist outage. |
| 12/27/2022 | HOISTING | ACCIDENT ONLY | None | Water line broke in the production shaft. |
| 12/01/2022 | HANDTOOLS (NONPOWERED) | DAYS RESTRICTED ACTIVITY ONLY | 74d restricted | An employee was conducting rehab work in 12N 30 Block. While hand scaling, a rock fell from a shelf and struck an employee's right hand causing a small fracture. |
| 10/20/2022 | HOISTING | ACCIDENT ONLY | None | The head ropes on the Koepe hoist crossed. |
| 09/18/2022 | HOISTING | ACCIDENT ONLY | None | Lost power to the production hoist due for slack rope fault. |
| 09/14/2022 | HOISTING | ACCIDENT ONLY | None | A skip on the production hoist traveled through the limit switch which kicked power to the hoist. |
| 09/13/2022 | HOISTING | ACCIDENT ONLY | None | The head ropes on the Koepe hoist crossed. |
| 09/06/2022 | HOISTING | ACCIDENT ONLY | None | Koepe hoist went down due to torque in the trailing cable. |
| 08/30/2022 | HOISTING | ACCIDENT ONLY | None | The head ropes on the Koepe hoist crossed. |
| 08/23/2022 | HOISTING | ACCIDENT ONLY | None | The head ropes on the Koepe hoist were twisted. |
| 08/13/2022 | HOISTING | ACCIDENT ONLY | None | Koepe hoist went down due to torque in the trailing cable. |
| 08/08/2022 | HOISTING | ACCIDENT ONLY | None | Electricity to the mine was lost due to a storm. As a result, the production hoist was inoperable. |
| 07/05/2022 | HOISTING | ACCIDENT ONLY | None | The south loading gate at the production shaft bottom stuck open making the hoist inoperable. |
| 06/24/2022 | HOISTING | ACCIDENT ONLY | None | The Koepe hoist wasn't syncing and was unable to be operated. Resolver motor wasn't functioning. |
| 01/26/2022 | HOISTING | ACCIDENT ONLY | None | A 120v control power breaker for the dynamic braking system tripped causing the hoist motor control circuit to drop out. |