| 05/16/2006 | HANDLING OF MATERIALS | DYS AWY FRM WRK & RESTRCTD ACT | 4d lost, 198d restricted | Employee was attempting to remove a steel airlock door frame when it fell and struck him on the right side of his torso. |
| 04/19/2006 | HOISTING | ACCIDENT ONLY | None | Bad top door landing switch. Elevator was repaired and put back into service at 2:52 a.m. |
| 04/12/2006 | HOISTING | ACCIDENT ONLY | None | The elevator doors would not open or close properly. The doors were adjusted and elevator put back in service at 09:02 am. |
| 04/04/2006 | HOISTING | ACCIDENT ONLY | None | Broken cable pulley for Main Portal Elevator doors. Elevator was repaired, inspected and put back into service at 10:25 a.m. on 4/5/06. |
| 04/03/2006 | HOISTING | ACCIDENT ONLY | None | After mine examination and power restored (power company had power off last shift) found electrical problem with hoist. Blown fuse was replaced and hoist was put back in operation at 8:45 a.m. |
| 03/31/2006 | HOISTING | ACCIDENT ONLY | None | Due to high winds, Main Portal Facility lost power causing loss of elevator and slope. Power was re-established at 12:35 a.m. on 4/1/06 and elevator and slope were back in service. |
| 02/27/2006 | HOISTING | ACCIDENT ONLY | None | Slope brake car came off the tracks. It was put back on the tracks and in service at 3:15 p.m. |
| 02/24/2006 | HOISTING | ACCIDENT ONLY | None | Slope hoist overtravel was out of adjustment. Repairs were made and hoist was put back in service at 9:50 p.m. |
| 02/03/2006 | HANDLING OF MATERIALS | NO DYS AWY FRM WRK,NO RSTR ACT | None | Employee was applying plaster to a ventilation stopping underground. As he climbed off ladder, plaster bucket fell and struck his upper lip causing laceration. Employee received medical treatment of... |
| 01/31/2006 | HANDTOOLS (NONPOWERED) | DAYS AWAY FROM WORK ONLY | 111d lost | Employee was swinging a sledge hammer when he felt pain in his right shoulder. He continued working until 8/30/06 when he had shoulder surgery and began missing work. |
| 01/26/2006 | MACHINERY | DYS AWY FRM WRK & RESTRCTD ACT | 37d lost, 77d restricted | Employee was lowering canopy on roof bolter when the edge of the canopy hung up on edge of TRS. Canopy fell, striking employee on head, causing neck and shoulder pain. Employee continued to work unt... |
| 01/25/2006 | HOISTING | ACCIDENT ONLY | None | Brakes locked up on brake car 300 feet from top. Adjusted speed sensor and put brake car back in service at 2:00 pm. on 1/25/06. |
| 01/16/2006 | HANDTOOLS (NONPOWERED) | NO DYS AWY FRM WRK,NO RSTR ACT | None | While lowering arm of bin whip apparatus through a hatch on top of Raw Coal Silo 1, employee's left index finger was pinched between a bar and the floor (floor = top of silo), causing lacerations to t... |
| 01/15/2006 | SLIP OR FALL OF PERSON | DYS AWY FRM WRK & RESTRCTD ACT | 125d lost, 9d restricted | Employee was exiting door after changing filter at fuel tank when the metatarsal guard on his boot caught on bottom of door and he fell striking his forehead, left knee and tooth. He started missing... |
| 01/13/2006 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | A roof fall occurred in the first north submain entries off the main east entry 3 crosscut 40. The fall measured approximately 16' wide x ? longx thickness ? The fall did not result in any damage to e... |
| 12/14/2005 | HOISTING | ACCIDENT ONLY | None | Electrical landing problem was discovered at 1 p.m. on 12/14/05. Problem was repaired and Alimak was put back in service at 3 p.m. on 12/16/05. |
| 11/30/2005 | HANDLING OF MATERIALS | DAYS AWAY FROM WORK ONLY | 140d lost | Employee was loading ""J"" channels when he felt pain in his back. |
| 11/08/2005 | HOISTING | ACCIDENT ONLY | None | Brake car locked 100 feet up from ""Y."" Repairs were made and brake car put back in service at 3:55 p.m. |
| 11/07/2005 | FALL OF FACE/RIB/PILLAR/SIDE/HIGHWALL | DAYS RESTRICTED ACTIVITY ONLY | 4d restricted | A supervisor was struck on his left ankle by a rock approximately 12"" x 12"" x 8"" that fell from longwall face. |
| 10/31/2005 | HOISTING | ACCIDENT ONLY | None | Main Portal Elevator doors would not open due to electrical contacts. Problem was repaired and elevator put back into service at 11:24 a.m. |
| 10/29/2005 | HOISTING | ACCIDENT ONLY | None | Door rod bent on Main Portal Elevator. Door rod was repaired and elevator was put back into service at 6:00 p.m. |
| 10/19/2005 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | A fall of roof occurred at the 10th East Gateroad, Entry 2, Crosscut 89. The fall measured approximately 30' long x 16' wide x thickness? The fall did not result in any damage to equipment or proper... |
| 10/14/2005 | HOISTING | ACCIDENT ONLY | None | Slope hoist was inoperable. Wires in control cabinet in engine room shorted out. Repairs were made and hoist was put back in service at 2:15 p.m. on 10/15/05. |
| 10/06/2005 | OTHER | DAYS AWAY FROM WORK ONLY | 6d lost | Employee was cleaning in clean coal pit when he felt stinging sensation from bee/insect on his left elbow. |
| 10/04/2005 | HOISTING | ACCIDENT ONLY | None | Brake car brakes dragging. Brakes were adjusted and car was put back in service at 2:50 p.m. on 10/4/05. |
| 10/01/2005 | HANDLING OF MATERIALS | NO DYS AWY FRM WRK,NO RSTR ACT | None | Employee was shoveling coal spill underground when a foreign particle entered his left eye. Foreign object had to be medically removed and employee was given prescription medication. |
| 09/28/2005 | DISORDERS (REPEATED TRAUMA) | OCCUPATNAL ILLNESS NOT DEG 1-6 | 1d lost | Employee stated he has pain in both shoulders from long-term roof bolting. On 11/28/05 employee received an injection in his left shoulder to treat ""frozen"" shoulder. Due to injection, employee mi... |
| 09/27/2005 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | A fall at the anchorage point occurred on the longwall tailgate resulting in loss of egress for approximately 15 minutes. The fall measured approximately 16' x 16' x 9'. It was located 35' outby inter... |
| 09/25/2005 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | A fall at the anchorage point occurred on the longwall tailgate resulting in loss of egress for approximately 60 minutes. The fall measured approximately 16' x 16' x 9'. It was located 35' inby intere... |
| 09/06/2005 | HOISTING | ACCIDENT ONLY | None | Slope hoist experienced electrical problems and was out of service for 2 hours and 5 minutes. |
| 09/02/2005 | POWERED HAULAGE | ACCIDENT ONLY | None | Slope brake car derailed. Brake car was out of service for 2 hours and 2 minutes. |
| 08/24/2005 | HOISTING | ACCIDENT ONLY | None | Safety feature on elevator door malfunctioned, causing loss of use of elevator for 4 hours and 40 minutes. |
| 08/22/2005 | HOISTING | ACCIDENT ONLY | None | During lowering of materials a slope hoist overspeed event occurred, causing loss of slope facility for about 26 hours. |
| 08/22/2005 | SLIP OR FALL OF PERSON | DYS AWY FRM WRK & RESTRCTD ACT | 62d lost, 23d restricted | Employee was walking in work environment when he twisted his right foot. Information was received on 10/17/05 confirming the work-relatedness of the foot injury. |
| 08/19/2005 | MACHINERY | DAYS RESTRICTED ACTIVITY ONLY | 42d restricted | During process of roof bolting, employee was holding drill auger when the hydraulic drill clamp closed on right thumb, causing fracture. Employee returned to work on restricted duty. |
| 08/15/2005 | SLIP OR FALL OF PERSON | DAYS AWAY FROM WORK ONLY | 16d lost | Employee was washing floor in shower area using a garden hose when hose caught on bench leg. As employee tried to free hose, he slipped and twisted his left knee. On 12/1/05 employee had surgery to... |
| 08/11/2005 | HOISTING | ACCIDENT ONLY | None | Slope hoist had electrical problem, leaving hoist inoperable. Electrical problem was repaired on 8/12/05. Bottom slope doors were repaired on 8/15/05 and slope hoist was put back into service at 8:0... |
| 08/05/2005 | HANDLING OF MATERIALS | DAYS AWAY FROM WORK ONLY | 219d lost | Employee was building cribs and when he threw a crib on the very top, it caught on wire mesh and jarred his right shoulder. Employee continued to work until 1/13/06 when surgery was performed on his... |
| 07/29/2005 | HANDTOOLS (NONPOWERED) | DAYS RESTRICTED ACTIVITY ONLY | 54d restricted | Employee was using a pry bar to align a shield hydraulic cylinder when the bar slipped causing him to suddenly twist and feel pain in his knee. Employee was diagnosed with a sprain, including tear in... |
| 07/26/2005 | HOISTING | ACCIDENT ONLY | None | The inspection of the emergency elevator revealed the outside door latch was not working properly. The outside door latch mechanism was found to be out of adjustment. The latch mechanism was adjusted... |
| 07/25/2005 | HOISTING | ACCIDENT ONLY | None | The slope hoist main power control fuse was failing while operating the hoist. A contractor with better experience with the circuit was called in to assist in trouble shooting cause of problem. He fou... |
| 07/19/2005 | HANDLING OF MATERIALS | NO DYS AWY FRM WRK,NO RSTR ACT | None | Dust particle fell into employee's left eye while he was plastering a ventilation wall, causing a corneal abrasion. Employee was given prescription medication for infection. |
| 06/30/2005 | HANDLING OF MATERIALS | DYS AWY FRM WRK & RESTRCTD ACT | 18d lost, 56d restricted | Employee felt a sudden pain in his right arm as he attempted to a lift a 38-lb. plastic tote box onto the back of a supply vehicle. Employee ruptured the distal biceps tendon on his right arm. |
| 06/09/2005 | HOISTING | ACCIDENT ONLY | None | Elevator had noticeable vibration while operating. Elevator was shut down until elevator service company repairmen were able to change some bad guide rollers. The elevator was put back in service at 9... |
| 05/25/2005 | HOISTING | ACCIDENT ONLY | None | Elevator went past bottom landing and tripped over travel switch. Brakes were making a noise, upon checking found brakes needed adjustment. Schindler elevator service company called to make necessary... |
| 05/25/2005 | HOISTING | ACCIDENT ONLY | None | Elevator overtraveled the top landing. The counter weight buffer switch was reset and adjusted. Several round trips were performed and elevator put back in service at 4:30 pm. |
| 05/20/2005 | HOISTING | ACCIDENT ONLY | None | The main elevator overtraveled the bottom landing 6"". The elevator was put in manual mode and raised to the proper landing level, and reset to automatic mode. The elevator was test run a couple trips... |
| 05/10/2005 | MACHINERY | NO DYS AWY FRM WRK,NO RSTR ACT | None | Employee was using hand-held grinder on metal surface and felt irritation in right eye. Foreign particles were removed and employee was given prescription eye drops. |
| 05/06/2005 | MACHINERY | NO DYS AWY FRM WRK,NO RSTR ACT | None | Employee was using air nailer to assemble wooden forms when nail penetrated employee's left index finger. |
| 05/06/2005 | HANDLING OF MATERIALS | DAYS RESTRICTED ACTIVITY ONLY | 34d restricted | Employee was descending steps when he felt pain in his lower back. |