| 03/03/2008 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | North 3, 31 block, 4 entry, 4-way. 20ft wide x 20ft long x 8ft high. Support: 6ft 3/4 inch resin bolts, 12ft cable bolts and pans. Fall dangeged off, additional roof support installed around fall. |
| 02/25/2008 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | Old East 2, #5 entry, 13 block, MMU 003, 4-way intersection. 18' wide X 30' long X 8' high. Support: 6' 3/4"" resin bolts, pans , straps and 12' cable bolts. Fall dangered off, additional roof support... |
| 02/20/2008 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | 7 Mains 3, 4 entry, 3 block, 4-way, MMU 001. 25' wide X 22' long X 7' high. Support: 6' 3/4"" resin bolts, screen, pans, dywidag truss bolts, straps, cable truss, pans and straps. |
| 02/09/2008 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | 7 mains 2, 20 block, 4 entry, MMU 001 4 way #16630 17 ft. wide x 25 ft long x 7 ft high. Support 6 ft. 3/4 inch resin bolts, pans, brow straps, 12 ft cable bolts. Fall dangeged off, additional roof su... |
| 02/07/2008 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | 7 mains 2, 1 entry, 22 block, MMU 001 - 3-way intersection. 17' wide x 17' long x 7' high. Support: 6' 3/4"" resin bolts, pans, brow straps, cable truss bolts. Fall dangered off; additional roof suppo... |
| 02/07/2008 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | 7 mains 2, 2 entry, between 30 & 31 block, MMU 001. 17' wide x 20' long x 7' high. Support: 6' 3/4"" resin bolts, pans, brow straps, dywidag truss bolts. Fall dangered off; additional roof support ins... |
| 02/05/2008 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | 6 Mins 1, 3 entry, 16 block, MMU 007, 4 way intersection support; 6 ft 3/4 inch resin bolts, dywidag truss bolts 17 ft wide x 20 ft long x 78 ft high. Fall dangeged off, additional roof support instal... |
| 01/28/2008 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | 7 Mains 2, 2 entry, between 33 & 34 block, MMU 001 17 ft wide x 20 ft long x 6 ft high. Support: 6 ft 3/4 inch resin bolts, cable truss bolts, pans, brow straps. Fall dangered off, additional roof sup... |
| 01/27/2008 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | North 6, 22 block, 5 entry, MMU 003. 8 ft wide x 10 ft long x 4 ft high. Support: 6 ft 3/4 inch resin bolts, cable truss bolts, screen, pans, brow straps. Fall dangered off, additional roof support in... |
| 01/05/2008 | FALL OF ROOF OR BACK | DAYS AWAY FROM WORK ONLY | 20d lost | A thin piece of rock fell from between the roof bolts and struck the employee's hard hat and slid down his neck. X-ray was negative; bruise and 4 stitches to neck. He returned to work his next schedul... |
| 12/19/2007 | MACHINERY | DAYS AWAY FROM WORK ONLY | 9d lost | The employee stated that while drilling a hole, the drill steel bent and struck his right wrist. The x-ray was negative, bruise. |
| 12/06/2007 | FALL OF ROOF OR BACK | DAYS AWAY FROM WORK ONLY | 129d lost | The employee was loading supplies on the roof bolt machine and a rock (3ft x 3ft x 3in)fell from between the bolts and struck the employee on his hard hat. X-ray and CAT scan showed a small crack to o... |
| 12/06/2007 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | 7 Mains 2, 7 to 8 crosscut, 5 block, MMU 001. 40 ft long x 17 ft wide x 7 ft high. Support: 6 ft 3/4 inch resin bolts, pans, straps, cable truss bolts and screen. Fall dangered off, additional roof su... |
| 12/04/2007 | HANDTOOLS (NONPOWERED) | DAYS RESTRICTED ACTIVITY ONLY | 3d restricted | Employee was assisting in changing a busted water line and was using a come-a-long to pull the pipe. The chain slipped and struck his left hand. The x-ray was negative, bruise. |
| 11/28/2007 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | 7 Mains 2, 7 Entry, 26 Block, MMU 002. 25 ft wide x 25 ft long x 8 ft high. Support: 6 ft 3/4 inch resin bolts, pans, brow straps, 12 ft cable bolts. Fall dangered off, additional roof support install... |
| 11/09/2007 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | Old East 2, 7 entry, 7 block, MMU 008, 4-way intersection. 18' wide x 18' long x 7' high. Support: 6' 3/4"" resin bolts, screen, 12' cable bolts, cribs on both sides. Fall dangered off, additional roo... |
| 11/03/2007 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | 6 mains, 21 block, #2 entry, 4-way intersection, MMU 007-17ft wide x 30ft long x 7ft high-Support: 6ft 3/4 inch resin bolts, pans, brow straps, 12 ft cable bolts-Fall dangeged off, additional roof sup... |
| 10/31/2007 | POWERED HAULAGE | DAYS AWAY FROM WORK ONLY | 6d lost | Employee was riding in an encolsed manbus and the bus came to a sudden stop. No injury was reported to the supervisor, but the following morning the employee complained about numbness in his right sid... |
| 10/30/2007 | HANDLING OF MATERIALS | DAYS RESTRICTED ACTIVITY ONLY | 3d restricted | The ee was bending over to tie a pull rope on the miner cable and felt a pain in his lower back. Examination negative, strain (2 days restricted duty). |
| 10/27/2007 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | South 1, 69 block 8 entry, 4-way intersection, MMU 006-17 ft wide x 35 ft long x 12 ft high. Support: 6 ft 3/4 inch resin bolts, 12 ft cable bolts , pans, brow straps. Fall dangeged off, additional ro... |
| 10/24/2007 | MACHINERY | NO DYS AWY FRM WRK,NO RSTR ACT | None | The employee was installing a roof bolt and the steel was not drilling straight. The steel stuck in the chuck and when it came out, It pinched the ee's left hand between the steel and the chuck. 4- st... |
| 10/22/2007 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | 7 Mains, 11 entry between 31 & 32 block, MMU 002. 50' long x 17' wide x 8' high. Support: 6' 3/4"" resin bolts, cable truss. Fall dangered off, additional roof support installed around fall. |
| 10/11/2007 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | 6 Mains 4entyr, 14 block, MMU 007, 4-way intersection. 18' wide X 40' long X 8' high. Support: 6' 3/4"" resin bolts and cable bolts. Fall dangered off and additional roof support installed around fall... |
| 10/11/2007 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | 6 Mains 7 entry, 16 block, MMU 008, 4-way intersection. 8' wide X 10' long X 8' high. Support: 6' 3/4"" resin bolts, cable bolts and screen. Fall dangered off, additional roof support installed around... |
| 10/07/2007 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | North 4, 69 block, 5 entry, MMU 003, 4-way intersection 17' w x 25' l x 8' h. Support 6' 3/4"" resin bolts, screen 12' cable bolts, ACS jacks. Fall dangered off, additional roof support installed arou... |
| 10/02/2007 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | 7 Mains 2, 6 entry, 26 block, MMU 001, 4 Way. Support: 6 ft. 3/4 inch resin bolts, screen, pans, truss bolts, straps, 6 - 12 ft. cable. Fall dangered off, additional roof support installed around fall... |
| 09/29/2007 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | 6 Mains 2, 7 block, #5 entry, 4-way intersection, MMU 007. 17 ft. wide x 30 ft. long x 7 ft. high. Support: 6 ft. 3/4 inch resin bolts, pans, straps, 12 ft cable bolts. Fall dangered off, additional r... |
| 09/25/2007 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | 7 mains 2, 10 entry, 2 block, MMU 002-17' wide x 30' long x 7' high-support: 6'3/4"" resin bolts, pans, brow straps-fall dangeged off, additional roof support installed around fall. |
| 09/20/2007 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | 5 Mains, 28-29 block, #8 Entry, Spad # 16423. 18 ft wide x 30 ft long x 8 ft high. Fall dangered off, additional roof support installed around fall. Support: 6 ft 3/4 inch resin bolts, pans, brow stra... |
| 09/09/2007 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | 7 Mains 2, 6 entry, 33 block, 4-way, MMU 002. 18' wide X 25' long X 7' high. Support : 6' 34"" resin bolts, pans, brow straps and screen. Fall dangered off, additional roof support installed around fa... |
| 09/08/2007 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | 7 Mains 2, 4 entry, 33 block, 4-Way, MMU 001. 20 ft long x 20 ft wide x 8 ft high. Support: 6 ft 3/4 inch resin bolts, pans, brow straps. Fall dangered off, additional roof support installed around fa... |
| 09/07/2007 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | 7 Mains 2, 6 Entry, 31 Block, MMU 002, Spad #16590. 25 ft long x 18 ft wide x 7 ft high. Support: 6 ft 3/4"" resin bolts, pans. Fall dangered off, additional roof upport installed around fall. Fall cl... |
| 09/05/2007 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | North 7, 28 to 29 block, 4 entry MMU 003-3. 17 ft wide x 50 ft long x 7 ft high. Support: 6 ft 3/4 inch resin bolts, pans, brow straps. Fall dangered off, additional roof support installed around fall... |
| 09/04/2007 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | North 9, 9 block, 8 entry, MMU 004, 4 Way, spad #15717. 17 ft wide x 25 ft long x 7 ft high. Support: 6 ft 3/4 resin bolts, 12 ft cable bolts, pans, brow straps. Fall dangered off, additional roof sup... |
| 09/04/2007 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | 7 Mains 2, 25 to 25 block, 8 entry, MMU 002 Spad #16280. Support: 6 ft 3/4 inch resin bolts, pans, brow straps. Fall dangered off, additional roof support installed around fall. |
| 09/02/2007 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | 7 mains 2, 25 block, 7 entry, 4-way, MMU 001 Spad #16279. 15 ft long x 8 ft wide x 6ft high. Support: 6 ft 3/4 inch resin bolts, 12 ft cable bolts, pans, brow straps, screen. Fall dangered off, additi... |
| 08/31/2007 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | 7 mains 2, 7 entry, 31 block, 4-way, MMU 002 35' long x 70; wide x 9' high. Support: 6ft 3/4 inch resin bolts, pans, dewidag truss. Fall dangeged off, additional roof support installed around fall. Fa... |
| 08/31/2007 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | North 4, 64 block, 7 entry, MMU 002, 4-way intersection 15 ft long x 10 ft wide x 6 ft high, Support: 6 ft 3/4 inch resin bolts, pans, screen Fall dangeged off, additional roof support installed aroun... |
| 08/24/2007 | ELECTRICAL | DAYS RESTRICTED ACTIVITY ONLY | 5d restricted | EE was watching slack in cable while feeder was being moved. The cable caught on a belt stand & the EE grabbed the belt stand, not knowing that the stand caused a small cut in the cable. A slight shoc... |
| 08/22/2007 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | North 9, 23 block, 7 enry, MMU 004, 4 way. Support: 6' 3/4"" resin bolts, pan and brow straps. 17' wide X 20' long X 7' high. Fall dangered off, additional roof support installed around fall. Fall cle... |
| 08/16/2007 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | Correction/Entered incorrectly: North 6, 6 entry, between 15 & 16 block, MMU 004. 18' wide X 15' long X 6' high. Support: 6' 3/4"" resin bolts, pans, screen, bars and jacks. Fall dangered off, additio... |
| 08/16/2007 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | North 3, 7 entry, between 15 & 16 block, MMU 004. Support: 6 ft 3/4 inch resin bolts, cribs, pans, screen. 25 ft long x 17 ft wide x 6 ft high. Fall dangered off, additional roof support installed aro... |
| 08/16/2007 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | North 9, 7 Entry, 27 Block, MMU 004 Support: 6ft 3/4 inch resin bolts, cribs, 12 ft cablr bolt pans, screen. 40 ft long x 18 ft wide x 6 ft high. Fall dangered off, additional roof support installed a... |
| 08/04/2007 | HOISTING | ACCIDENT ONLY | None | The Connellsville, 66""W x 84"" Dia., 1 1/2"" rope, 300 HP slope hoist was down from 9:20 am until 10:30 am. All persons were removed from the mine after 30 minute time limit. |
| 07/31/2007 | MACHINERY | DAYS AWAY FROM WORK ONLY | 121d lost | The foreman was working on the truss bolter on the operator's side and was resting his left hand on the canopy. The bolt machine raised suddenly, pinching his left hand between the canopy and top. Fra... |
| 07/25/2007 | SLIP OR FALL OF PERSON | DAYS RESTRICTED ACTIVITY ONLY | 58d restricted | The employee was cleaning the hi-lift with a water hose. He was standing on the bucket and when he climbed down he slipped and struck his left hand on the bucket. X-Ray showed a simple fracture to the... |
| 07/15/2007 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | North 3, 38 Block, 6 Entry, MMU 004-0, 4-Way Intersection. 18 ft wide x 30 ft long x 6 ft high. Support: 6 ft 3/4 inch resin bolts, pans, brow straps, truss bolts, crib. Fall dangered off, additional... |
| 07/02/2007 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | 7 Mains 2, 4 entry, 2 block, MMU 001, 4-way. 20' long x 17' wide x 10' high. Support: 6' 3/4"" resin bolts, pans, 12' cable bolts, cribs, beams. Fall dangered off; additional roof support installed ar... |
| 06/27/2007 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | North 9, 9 block, 9 entry, 4-way MMU 004-20 ft long x 17 ft wide x 10 ft high, support: 6ft 3/4 inch resin bolts, pans 12ft cable bolts. fall dangered off, addional support installed around fall. |
| 06/26/2007 | FALL OF ROOF OR BACK | ACCIDENT ONLY | None | 6 Mains, 2 entry, 18 block, 4-way intersection, MMU 007. 17 ft wide x 25 ft long x 12 ft high. Support: 6 ft 3/4 inch resin bolts, 12 ft cable bolts, pans. Fall dangered off, additional roof support i... |